HUIRUIPU HRP-K6000-16 16-channel gas alarm controller, button model
4.3-Inch color screen, button operation, standard 16 Detectors, with indicator light + LCD display, buzzer alarm tone prompt, can store 20,000 alarm records.
HuiRuiPu-
GUOYUGRA GY/VGD-200-R407a-G Refrigerant, refrigerant Detector 0-1000ppm
$ 1190.00 -
Empaer APEG-D-H2S Volkswagen series stationary hydrogen sulfide Detector
$ 256.00 -
BOSEAN BH-90M-HCl Hydrogen chloride Gas Detector
$ 239.00 -
HUIRUIPU HRP-T1000-O2 Oxygen Gas Detector (no display with lamp)
$ 184.00 -
GUOYUGRA GY/VGD-200-C2H4-G (0-3% Vol) Ethylene Detector (Infrared)
$ 941.00
Introduction
The split-line gas detection and alarm controller is used to detect the content of flammable gases or toxic gases in the air, supports multiple 4-20mA signal input, and at the same time centrally controls multiple points. The system adopts a microprocessor as the Control Unit. When the concentration of flammable gases in the environment reaches or exceeds the preset value, the controller immediately emits sound and light alarms, and can drive exhaust or other peripheral actions through relays to prevent explosions and fire accidents, thereby protecting life. The system can be widely used in factories, oil depots, liquefied gas stations, gas stations, gas stations, paint spray rooms and other places that need fire protection and explosion-proof, for safety monitoring and alarming.
Operation panel

[OK] key: enter the menu or OK function
[Up] key: select menu item or shift operation
[Down] key: select menu item or change value
[Exit] key: return to the previous level menu or exit, it is also the [muffler] function when static. Indicator light: low report, high report, fault, power supply.
HuiRuiPu HRP-K6000-16 Line type gas alarm controllerSpecifications
| LIST | VALUE |
|---|---|
| Display | 4.3 inch color screen model |
| Operation mode | key operation |
| Operating Voltage | AC220V±10% 50HZ |
| backup Power | 24V 1.3AH lead-acid battery (optional) |
| switch output | Four sets of passive relay output, touchpoint Capacity 10A/AC220V |
| System Power | Maximum power consumption 10W (without external devices) |
| Number of Detectors | 16. |
| Detector connection | 4-20mA signal |
| data upload | RTU-standard modbus protocol |
| alarm point | Two-level alarm, can be freely set by the user |
| Alarm indication | Indicator light + LCD display, buzzer alarm tone prompt |
| Operating Mode | On-site fixed installation, wall hanging |
| Storage Capacity | It can store 20,000 alarm record messages |
| Appearance size | Size 245 * 340 * 90 (mm) |
| wiring specification | 3 wires need to be connected. It is recommended to use ≥ RVVP2 * 1.5 national standard Shielding wire, the diameter of the single core wire is ≥ 1.5mm, and the wire length is ≤ 1000m. |
HuiRuiPu HRP-K6000-16 Line type gas alarm controller Packing list
whole machine X1, operation manual X1, certificate of conformity X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- What is a styrene toxic gas alarm?
- What is an ozone gas alarm?
- What is a sulfur fluoride gas alarm?
- What is a methane combustible gas alarm?
- These details of the use of combustible gas alarms must be known!
- Explosion limits of various combustible gases
- Korno MOT-500N Online Gas Alarm Detector
- Korno MOT-500A Online Gas Alarm Detector, Product Introduction
- How to install and maintain RTP-JY150 gas (methane) gas alarm?
- Research on the Principle and Application of Combustible Gas Alarm


HRP-K6000-16
HRP-K6000-8