Measurement principle magnetic Induction + eddy Current, measurement range 0~1250μm, error range +/- 1~ 3% n or +/- 2.5μm, minimum measurement surface 6mm
Duban-
CHINA CTG-800-3000FN Coating Thickness Gauge integrated dual-use standard type
$ 220.00 -
Germany Knix QNix4500P/5 paints Thickness Gauge magnetic Induction/eddy Current thickness measurement 5/3mm
Login -
LANDTEK CM8821 Coating Thickness Gauge measurement of non-magnetic conductive coatings on ferromagnetic metal substrates
$ 236.00 -
LANDTEK CM8829F magnetic Thickness Gauge, integrated F magnetic Induction Film Thickness Gauge
$ 311.00 -
CHINA CTG-800-3000F Coating Thickness Gauge, Integrated Iron-based Standard Type
$ 207.00
Applications
The standard coating Thickness Gauge DB20-CM211C can store 99 sets of new measurement data values; it is the most widely used and the most accurate measurement, and can measure almost all metal substrates, whether iron-based or non-ferrous; and comes with RS-232C Data connection cable, USB data connection and Bluetooth transmission function; the integrated instrument is suitable for one-handed operation and the measurement is more stable, because the large contact surface of the large-type probe has better stability during measurement, allowing the user to get a continuous and Highly repeatable measurement results; the split type provides a variety of probes for greater measurement flexibility.
Features
Dual-purpose coating Thickness Gauge for iron-based and non-ferrous-based coatings.
There are two measurement methods available: single and continuous.
Metric/imperial unit conversion, with functions such as manual shutdown, automatic shutdown and under-Voltage prompt.
Automatically memorizes calibration values and automatically identifies the material of the measured substrate; there is a buzzer sound during operation, but the buzzer does not sound during continuous measurement.
Uses USB data cable output, RS-232C data cable and software to communicate with PC; optional Bluetooth™ data output option is also provided.
Duban DB20-CM211C Integral coating Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement principle | Magnetic Induction + eddy Current |
| Measurement range | 0~1250μm |
| margin of error | ±1~3%n ±2.5μm |
| Minimum measurement surface | 6mm |
| minimum curvature | F: convex 1.5mm/concave 25mm; N: convex 3mm/concave 50mm |
| thinnest substrate | 0.3mm |
| Unit display | Metric/Imperial |
| statistical function | 99 sets of data |
| Interface | USB,RS-232C,Bluetooth(选配) |
| Power | 2 * 1.5AAA No. 7 battery |
Duban DB20-CM211C Integral coating Thickness Gauge Packing list
Host X1, wrist rope buckle iron base (1 piece) X1, aluminum base (1 piece) X1, calibrated diaphragm (1 set) X1, measurement Sensors X1, portable case X1, operation manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 13448-2019
- ActiveISO 2808-2019
- AbolishGB/T 13448-2006
- AbolishISO 4042-1999
- ActiveQC/T 484-1999
- AbolishJB/T 5673-1991