Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> High-Low Temperature Chamber> HuiTai> HuiTai GDT-100A High and low temperature alternating climate Chamber

      HUITAI GDT-100A High and low temperature alternating climate chamber, alternating Humidity test chamber 100L/-20~ 150 ℃

      Temperature range -20~ 150 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, Temperature deviation ≤ +/- 2 ℃, Temperature Uniformity ≤ 2 ℃, Temperature resolution 0.1 ℃, Heating rate -40 ℃ → 100 ℃ 3~ 5 ℃/min, Cooling rate + 25 ℃ → -40 ℃ 1~ 1.5 ℃/min

      Brand
      SKU: NB044221
      China HuiTai
      VS
      Information
      Genuinegoods
      • HuiTai GDT-100A High and low temperature alternating climate ChamberOverview

      • Specifications
      • Comments
      • FAQs
      GDT-100A
      High and low temperature alternating climate Chamber
      • HUITAI GDT-100A High and low temperature alternating climate chamber, alternating Humidity test chamber 100L/-20~ 150 ℃
      • HUITAI GDT-100A High and low temperature alternating climate chamber, alternating Humidity test chamber 100L/-20~ 150 ℃ Figure 1
      • HUITAI GDT-100A High and low temperature alternating climate chamber, alternating Humidity test chamber 100L/-20~ 150 ℃ Figure 2
      Temperature range -20~ 150 ℃, Temperature Fluctuation ≤ +/- 0.5 ℃, Temperature deviation ≤ +/- 2 ℃, Temperature Uniformity ≤ 2 ℃, Temperature resolution 0.1 ℃, Heating rate -40 ℃ → 100 ℃ 3~ 5 ℃/min, Cooling rate + 25 ℃ → -40 ℃ 1~ 1.5 ℃/min

      Instrument interface

      GDT series configuration

      temperature range

      A:-20~150

      B:-40~150℃

      C:-60~150℃

      Humidity range20%~98% Relative Humidity (model with H)
      Display instrument7-inch TFT color LCD display (can be connected to RMCS control software)
      Operation modeFixed value mode, program mode (preset 100 groups, 100 steps, 999 cycles)
      control methodBTC balance temperature control method + DCC (intelligent cooling capacity control) + DEC (intelligent electrical control) (temperature test equipment)
      BTHC balance temperature and humidity control method + DCC (intelligent cooling capacity control) + DEC (intelligent electrical control) ( Temperature and humidity testing equipment)
      Curve recording functionIt has battery-protected RAM that can save the device’s setting values, sampling values ​​and sampling time; the
      maximum recording time is 350 days (when the sampling cycle is 1/min)
      Software usage environmentThe upper computer operating software is compatible with XP, Win7, Win8, and Win10 operating systems (provided by the user)
      Communication functionChoose one of RS-485 interface MODBUS RTU communication protocol and Ethernet interface TCP/IP communication protocol; support secondary development and
      provide host computer operation software, RS-485 interface single device link, Ethernet interface can realize remote communication of multiple devices Online.
      Way of workingA/B: Mechanical single-stage compression refrigeration system
      C: Two-stage cascade compressor refrigeration method
      way of observationHeated viewing window with LED internal lighting
      Temperature and humidity sensing methodTemperature: Class A PT100 armored thermocouple
      Humidity: Class A PT100 armored thermocouple
      Dry and wet bulb thermometer method (works only in tests with humidity control)
      safety protectionFault alarm and cause, processing prompt function, power-off protection function, upper and lower limit temperature protection function, calendar timing function
       (automatic start and automatic stop running), self-diagnosis function
      Verify configurationAccess hole with silicone plug (50 mm, 80mm, 100mm left)
      Data interfaceEthernet + software, USB data export, 0-40MA signal output

      Implementation standards

      GB/T5170.2-2008 Temperature test equipment

      GB/2423.1-2008 (1EC60068-2-1:2007) Low temperature test method AB.

      GB/2423.2-2008(1EC60068-2-2:2007) High temperature test method BA. GB/T5170.5-2008 Damp heat test equipment.

      GJB150.3(MIL-STD-810D) High temperature test method.

      GJB150.4(MIL-STD-810D) Low temperature test method.

      GB2423.3-93 (IEC68-2-3) Test Ca: Constant damp heat test method.

      GB2423.4-93(1EC68-2-30) Test Db: alternating damp heat test method.


      Equipment security protection

      Cooling System

      • Compressor overpressure protection

      • Compressor motor overheat protection

      • Compressor motor overcurrent protection

      humidification system

      • Humidification tube dry burning protection

      • Water supply abnormality protection

      • Water shortage abnormality protection

      Test chamber protection

      • Adjustable test space over-temperature protection

      • Air conditioning channel extreme over-temperature protection

      • Ultra-high temperature protection is set inside the controller

      • Fan motor overheat protection

      Other protection

      • Total power phase sequence and phase loss protection

      • Whole machine leakage protection

      • Load short circuit protection

      • Closed lightning protection


      Refrigeration process

      Refrigeration Compressors

      French Taikang fully enclosed compressor

      Way of working

      A/B: Mechanical single-stage compression refrigeration system

      C: Cascade compressor refrigeration method

      Evaporator

      High-efficiency components use slope-type evaporators (AC&R compound spoiler-type aluminum fins)

      condenser

      Adopt water cooling system to facilitate equipment movement, etc.

      heat exchanger

      Ultra-high efficiency SWEP plate type cold coal cold and heat exchange design is more efficient than the traditional internal spiral type

      Installation process

      1. Adopt nitrogen flushing welding process, use oxygen-free copper pipes for low-temperature connecting pipes, and use 48-hour high pressure-maintaining and anti-leakage process to ensure welding quality.

      2. The pipeline installation adopts the bending process of pipe bending machine. Elbow welding is not allowed in the turning parts.

      3. The low-temperature pipeline is equipped with shock-absorbing process pipes, and the refrigeration unit uses shock-absorbing springs and foot pads for shock absorption and noise reduction.

      4. The filter dryer absorbs residual moisture, particles, impurities, and acidic substances in the refrigeration system.

      5. The selection of solenoid valves is mainly based on brand. Necessary valve core cooling protection measures should be taken when welding solenoid valves to prevent damage or shortening of service life.


      VS

      HuiTai GDT-100A High and low temperature alternating climate ChamberSpecifications

      LIST VALUE
      Temperature range -20~150℃
      Temperature Fluctuation ≤±0.5℃
      Temperature deviation ≤±2℃
      Temperature Uniformity ≤2℃
      Temperature Resolution 0.1℃
      Heating rate -40 ℃ → 100 ℃ 3~ 5 ℃/min (mechanical refrigeration, under standard load)
      Cooling rate + 25 ℃ → -40 ℃ 1~ 1.5 ℃/min (mechanical refrigeration, under standard load)
      Standard load Capacity 1Kg aluminum sheet, 200W calorific value
      Interior Volume 100L
      Voltage 220V/25A
      Power 4.5Kw
      Interior size 500*400*500mm
      Dimensions 700*1300*1600m

      HuiTai GDT-100A High and low temperature alternating climate Chamber Packing list

      Host X1, instruction manual X1, certificate X1, Shelf X2

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Linear dispersion recording function of high and low temperature alternating climate chamber?
      [A]
      The GDT-100A device has built-in RAM with battery protection, which can save the device's settings, sampling values, and sampling time. The maximum recording time can be up to 350 days (when the sampling period is 1 minute).
      [Q]
      What technology is used in the refrigeration system of GDT-100A high and low temperature alternating climate box?
      [A]
      Type A/B mechanical single-stage compression refrigeration system, Type C adopts double-stage cascade compressor refrigeration method, equipped with high-efficiency component slope evaporator and SWEP plate cold coal cold and heat exchange design to ensure refrigeration efficiency and Stability.
      [Q]
      What interfaces does the communication function of the GDT-100A high and low temperature alternating climate box support?
      [A]
      The device is equipped with RS-485 interface to support MODBUS RTU Communication protocol, and optional Ethernet interface to support TCP/IP Communication protocol, which is convenient for remote communication Connectivity of multiple devices.
      [Q]
      What are the characteristics of the Control mode of GDT-100A high and low temperature alternating climate box?
      [A]
      High and low temperature alternating climate box adopts BTC equilibrate Temperature Control mode, combined with DCC intelligent cooling capacity control and DEC intelligent electrical control technology. In the temperature Humidity test equipment, BTHC equilibrate Conditioning Control mode can also be selected.
      HuiTai
      HUITAI GDT-100A High and low temperature alternating climate chamber, alternating Humidity test chamber 100L/-20~ 150 ℃
      Service