      Home> High-Low Temperature Chamber> HuiTai> HuiTai GDT-150CH High and low temperature alternating climate Chamber

      HUITAI GDT-150CH high and low temperature alternating Climate Chamber with Humidity control 150L/-60~ 150 ℃

      Temperature range -60~ 150 ℃, Humidity range 20% R.H~ 98% R.H, Studio volume 150L, Voltage 220V/25A, Power 4.5Kw, Inner chamber dimensions 500 * 500 * 600mm.

      Brand
      SKU: NB044242
      China HuiTai
      VS
      Information
      Genuinegoods
      • HuiTai GDT-150CH High and low temperature alternating climate ChamberOverview

      • Specifications
      • Comments
      • FAQs
      GDT-150CH
      High and low temperature alternating climate Chamber
      • HUITAI GDT-150CH high and low temperature alternating Climate Chamber with Humidity control 150L/-60~ 150 ℃
      • HUITAI GDT-150CH high and low temperature alternating Climate Chamber with Humidity control 150L/-60~ 150 ℃ Figure 1
      • HUITAI GDT-150CH high and low temperature alternating Climate Chamber with Humidity control 150L/-60~ 150 ℃ Figure 2
      Temperature range -60~ 150 ℃, Humidity range 20% R.H~ 98% R.H, Studio volume 150L, Voltage 220V/25A, Power 4.5Kw, Inner chamber dimensions 500 * 500 * 600mm.

      Instrument interface

      GDT series configuration

      temperature range

      A:-20~150

      B:-40~150℃

      C:-60~150℃

      Humidity range20%~98% Relative Humidity (model with H)
      Display instrument7-inch TFT color LCD display (can be connected to RMCS control software)
      Operation modeFixed value mode, program mode (preset 100 groups, 100 steps, 999 cycles)
      control methodBTC balance temperature control method + DCC (intelligent cooling capacity control) + DEC (intelligent electrical control) (temperature test equipment)
      BTHC balance temperature and humidity control method + DCC (intelligent cooling capacity control) + DEC (intelligent electrical control) ( Temperature and humidity testing equipment)
      Curve recording functionIt has battery-protected RAM that can save the device’s setting values, sampling values ​​and sampling time; the
      maximum recording time is 350 days (when the sampling cycle is 1/min)
      Software usage environmentThe upper computer operating software is compatible with XP, Win7, Win8, and Win10 operating systems (provided by the user)
      Communication functionChoose one of RS-485 interface MODBUS RTU communication protocol and Ethernet interface TCP/IP communication protocol; support secondary development and
      provide host computer operation software, RS-485 interface single device link, Ethernet interface can realize remote communication of multiple devices Online.
      Way of workingA/B: Mechanical single-stage compression refrigeration system
      C: Two-stage cascade compressor refrigeration method
      way of observationHeated viewing window with LED internal lighting
      Temperature and humidity sensing methodTemperature: Class A PT100 armored thermocouple
      Humidity: Class A PT100 armored thermocouple
      Dry and wet bulb thermometer method (works only in tests with humidity control)
      safety protectionFault alarm and cause, processing prompt function, power-off protection function, upper and lower limit temperature protection function, calendar timing function
       (automatic start and automatic stop running), self-diagnosis function
      Verify configurationAccess hole with silicone plug (50 mm, 80mm, 100mm left)
      Data interfaceEthernet + software, USB data export, 0-40MA signal output

      Implementation standards

      GB/T5170.2-2008 Temperature test equipment

      GB/2423.1-2008 (1EC60068-2-1:2007) Low temperature test method AB.

      GB/2423.2-2008(1EC60068-2-2:2007) High temperature test method BA. GB/T5170.5-2008 Damp heat test equipment.

      GJB150.3(MIL-STD-810D) High temperature test method.

      GJB150.4(MIL-STD-810D) Low temperature test method.

      GB2423.3-93 (IEC68-2-3) Test Ca: Constant damp heat test method.

      GB2423.4-93(1EC68-2-30) Test Db: alternating damp heat test method.


      Equipment security protection

      Cooling System

      • Compressor overpressure protection

      • Compressor motor overheat protection

      • Compressor motor overcurrent protection

      humidification system

      • Humidification tube dry burning protection

      • Water supply abnormality protection

      • Water shortage abnormality protection

      Test chamber protection

      • Adjustable test space over-temperature protection

      • Air conditioning channel extreme over-temperature protection

      • Ultra-high temperature protection is set inside the controller

      • Fan motor overheat protection

      Other protection

      • Total power phase sequence and phase loss protection

      • Whole machine leakage protection

      • Load short circuit protection

      • Closed lightning protection


      Refrigeration process

      Refrigeration Compressors

      French Taikang fully enclosed compressor

      Way of working

      A/B: Mechanical single-stage compression refrigeration system

      C: Cascade compressor refrigeration method

      Evaporator

      High-efficiency components use slope-type evaporators (AC&R compound spoiler-type aluminum fins)

      condenser

      Adopt water cooling system to facilitate equipment movement, etc.

      heat exchanger

      Ultra-high efficiency SWEP plate type cold coal cold and heat exchange design is more efficient than the traditional internal spiral type

      Installation process

      1. Adopt nitrogen flushing welding process, use oxygen-free copper pipes for low-temperature connecting pipes, and use 48-hour high pressure-maintaining and anti-leakage process to ensure welding quality.

      2. The pipeline installation adopts the bending process of pipe bending machine. Elbow welding is not allowed in the turning parts.

      3. The low-temperature pipeline is equipped with shock-absorbing process pipes, and the refrigeration unit uses shock-absorbing springs and foot pads for shock absorption and noise reduction.

      4. The filter dryer absorbs residual moisture, particles, impurities, and acidic substances in the refrigeration system.

      5. The selection of solenoid valves is mainly based on brand. Necessary valve core cooling protection measures should be taken when welding solenoid valves to prevent damage or shortening of service life.


      VS

      HuiTai GDT-150CH High and low temperature alternating climate ChamberSpecifications

      LIST VALUE
      Temperature range -60~150℃
      Temperature Fluctuation ≤±0.5℃
      Temperature deviation ≤±2℃
      Temperature Uniformity ≤2℃
      Temperature Resolution 0.1℃
      Heating rate -40 ℃ → 100 ℃ 3~ 5 ℃/min (mechanical refrigeration, under standard load)
      Cooling rate + 25 ℃ → -40 ℃ 1~ 1.5 ℃/min (mechanical refrigeration, under standard load)
      Humidity range 20% R. H~ 98% R. H (see Temperature Humidity Controllable Chart)
      Humidity Deviation ≤±3%R.H
      Humidity stability ±1.5%R.H
      Humidity resolution 0.1%R.H
      Standard load Capacity 1Kg aluminum sheet, 200W calorific value
      Interior Volume 150L
      Voltage 220V/25A
      Power 4.5Kw
      Interior size 500*500*600mm
      Dimensions 700*1400*1700m

      HuiTai GDT-150CH High and low temperature alternating climate Chamber Packing list

      Host X1, instruction manual X1, certificate X1, Shelf X2

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      How do high and low temperature alternating climate chambers support the application of New materials in the R & D process?
      [A]
      GDT-150CH's Humidity control accuracy and large volume studio make it a tool for New materials research and development. Researchers can use its diverse Humidity environment settings to evaluate the performance and Stability of New materials in different climate conditions to optimize material design and application.
      [Q]
      Can GDT-150CH high and low temperature alternating climate box be used for Reliability testing of electronic components?
      [A]
      Yes, the GDT-150CH offers a wide Humidity range, making it ideal for Reliability and Stability testing of electronic components. Its accurate Temperature and Humidity control functions can simulate performance changes in different working environments, ensuring component Reliability in various application scenarios.
      [Q]
      How can remote communication and data management capabilities optimize industrial production processes?
      [A]
      The GDT-150CH provides RS-485 and Ethernet interfaces, supports MODBUS RTU and TCP/IP Communication protocols, and can realize remote monitoring and control of single or multiple devices. The factory can realize the integrated management of equipment through the host computer operation software to improve production efficiency and product conformity.
      +HuiTai GDT-150CH High and low temperature alternating climate Chamber Big data
        +HuiTai GDT-150CH High and low temperature alternating climate ChamberSimilar products
        +HuiTai GDT-150CH High and low temperature alternating climate ChamberKnowledge
        +HuiTai GDT-150CH High and low temperature alternating climate ChamberStandard
        +Navigation
        HuiTai
        HUITAI GDT-150CH high and low temperature alternating Climate Chamber with Humidity control 150L/-60~ 150 ℃
        Service
        Focus on online sales of Lab Testing Instruments