ZIBO KLS100 Volumetric Moisture Analyzer Karl-Fischer Moisture Analyzer
Test accuracy is high, the end point indication is accurate, easy to use, stable performance, low price, effectively replace the traditional manual visual KF-1 Moisture Analyzer.
zibo-
KF-4 Reagent ZDY-502/ZDY-504
$ 197.00 -
Zibo Coulomb SF-3 Trace Moisture Meter, Carl Moisture Meter 5μg~ 100mg
$ 1358.00 -
TOKY MS3000 Karl Fischer Moisture Titrator 0.0001%~ 100%
$ 1268.00 -
Zibo Coulomb SF-1 Trace Moisture Meter, Karl-Fischer Coulomb Electricity Method 5μg~ 80mg
$ 1246.00 -
Zibo Coulomb SF-3B Trace Moisture Analyzer, Magnetic Stirring 5μg~ 100mg
$ 1619.00
Introduction
Zibo Coulomb KLS100 volumetric moisture analyzer is a super economical automatic Karl Fischer moisture measuring product. The instrument uses volumetric titration with Karl-Fischer reagent as the standard solution as the analysis principle, and has an end-point indication function. It has high testing accuracy, accurate end point indication, easy to use, stable performance, and low price. It can effectively replace the traditional manual visual KF-1 Moisture Meter. This instrument is mainly used to measure the moisture content in chemical, pharmaceutical, food and other industrial products. It is also suitable for chemical laboratories and quality inspection departments in various hospitals, pharmaceutical factories, veterinary medicine factories, beverage factories, chemical enterprises and other industries.
Features
1. Using ordinary Karl-Fischer reagent as standard solution, the measurement is simple, rapid and accurate;
2. There are two measurement methods: manual and automatic. The solenoid valve is used to adjust the measurement flow and automatically indicate the end point;
3. After starting the measurement, the instrument automatically adjusts fast titration according to the water content, and automatically switches to slow titration near the end point, making the measurement fast and accurate;
4. The instrument has an automatic end-point locking device, a red light indicator for the end point, and a buzzer reminder when measuring the end point;
5. The instrument has a built-in stepless speed-adjustable electromagnetic stirrer;
6. The instrument is equipped with an automatic waste discharge device, which eliminates the need to manually remove waste liquid and is safe and convenient to use;
7. The instrument is easy to repair and maintain. There is no need to turn on the machine to replace parts. The operator can easily perform instrument maintenance operations;
8. Valve and pipeline materials: three-way two-way electromagnetic drive control valve, anti-corrosion material pipeline.
zibo KLS100 Volumetric Moisture AnalyzerSpecifications
| LIST | VALUE |
|---|---|
| Moisture Measurement Range | 30ppm-100% |
| Burette | 10Ml Automatic Burette |
| indexing | 0.05Ml (configured by the user) |
| External electrode | Double platinum electrode |
| polarization Voltage | -40mV |
| Sensitivity | 10-6A |
| destination indication | Ammeter scale |
| destination indication delay | 10-15 seconds |
| Measurement time | 30 seconds to a few minutes |
| Environmental temperature | 5-35℃ |
| Environmental humidity | ≤80% |
| Power | 30w |
zibo KLS100 Volumetric Moisture Analyzer Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Plastics - Determination of polyethylene (PE) moisture content
- How much do you know about the accuracy of Karl Fischer Moisture Titrator?
- Karl Fischer Moisture Titrator: Type Analysis, Application Scenarios, and Scientific Selection Guide
- ActiveGB/T 2092-2024
- ActiveSH/T 0078-1991
- ActiveGB/T 17529.1-2023
- ActiveGB/T 5832.3-2011
- ActiveGB/T 5832.4-2020
- ActiveGB/T 6027-2023
- ActiveGB/T 11133-2015
- ActiveGB/T 7376-2008
- AbolishGB/T 23357-2009
- ActiveGB/T 25154-2010
- ActiveGB/T 26626-2011
- ActiveGB/T 5832.1-2016
- ActiveGB/T 37191-2018
- ActiveGB/T 42022-2022
- ActiveGB/T 26793-2011


KLS100