      CHINA LHS-80 Constant Temperature and Humidity Chamber humidity cabinet testing machine 55 ℃/50~90% RH/80L

      Temperature range 5-55 ℃, Temperature resolution 0.1 ℃, Temperature Fluctuation High temperature +/- 1 ℃ Low temperature +/- 2 ℃, Humidity control range 50-90% RH, Humidity deviation +/- 5-8% RH, Input Power 1200W, liner size 400 * 400 * 500.

      Brand
      SKU: NB044450
      China Factory
      Stock
      Loading…
      Price
      $ 916.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • Factory LHS-80 Constant Temperature and Humidity ChamberOverview

        • Specifications
        • Comments
        • FAQs
        LHS-80
        Constant Temperature and Humidity Chamber
        • CHINA LHS-80 Constant Temperature and Humidity Chamber humidity cabinet testing machine 55 ℃/50~90% RH/80L
        Temperature range 5-55 ℃, Temperature resolution 0.1 ℃, Temperature Fluctuation High temperature +/- 1 ℃ Low temperature +/- 2 ℃, Humidity control range 50-90% RH, Humidity deviation +/- 5-8% RH, Input Power 1200W, liner size 400 * 400 * 500.

        The LHS series of intelligent constant temperature and Humidity Chambers have temperature and humidity control systems, which can provide various environmental simulation conditions required for industrial research and biotechnology testing.

        Features

        1. It adopts 304 mirror stainless steel inner tank, with semi-circular arc around it for easy cleaning, and the interval between the partitions in the box is adjustable.

        2. Using sonic humidification, the humidification is reliable and the humidity is uniform.

        3. High-precision, large-capacity humidity generator. Humidity control occurs quickly, with high precision and small fluctuations.

        4. Use imported humidity sensors to avoid the trouble caused by frequent replacement of wet and dry bulb belts.

        5. It has 30 levels of programmable temperature and humidity.

        6. Equipped with an independent temperature limit alarm system, which will automatically interrupt when the temperature exceeds the limit to ensure the safety of the experiment and no accidents (optional)

        7. It can be equipped with a printer or RS485 interface for connecting to a printer or computer, which can record changes in humidity parameters. (optional)

        Series model

        Technical indicatorsLHS-80LHS-150LHS-250LHS-450
        Temperature control range5-55℃
        temperatureresolution0.1℃
        VolatilityHigh temperature ±1℃ Low temperature ±2℃
        Humidity control range50-90%RH
        Humidity deviation±5-8%RH
        input power1200W1760W2500W3000w
        Working temperature+5~35℃
        VoltageAC220V 50HZ
        sizeLiner400*400*500550*400*680600*500*830700*650*950
        outer bladder550*790*1080700*840*1430750*900*1580880*830*1700
        load carrier2 pieces
         Note: The performance parameter test under no-load conditions is: ambient temperature 20℃, ambient humidity 50%RH


        VS

        Factory LHS-80 Constant Temperature and Humidity ChamberSpecifications

        LIST VALUE
        Temperature range 5-55℃
        Temperature Resolution 0.1℃
        Temperature Fluctuation High temperature +/- 1 ℃ Low temperature +/- 2 ℃
        Humidity control range 50-90%R.H
        Humidity Deviation ±5-8%R.H
        Input Power 1200W
        Ambient Temperature +5~35℃
        Power AC220V 50HZ
        Interior size 400*400*500mm
        Shelf (std.) 2pcs

        Factory LHS-80 Constant Temperature and Humidity Chamber Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Our Laboratory Needs Drug Stability Testing, Which Constant Temperature and Humidity Chamber Should We Choose?
        [A]
        LHS-80 Constant Temperature and Humidity Chamber Temperature range 5-55 ℃, humidity control range 50-90% RH, fully meet the Environmental requirements of Pharmacopoeia for Stability testing. 304 mirror stainless steel liner is easy to clean, avoid cross contamination, and can be programmed in 30 segments to simulate different storage conditions.
        [Q]
        We need to record Temperature and Humidity data, what function should we choose?
        [A]
        It is recommended to choose an RS485 interface or printer, so that changes in temperature and Humidity parameters can be recorded in real time. LHS-80 itself has high-precision control and data recording function, which is very suitable for quality inspection and scientific research experiments that require test reports.