CHINA NBC-5604-10B thermostatic tape holding tack testing machine
10 stations, pressure roller load 2000 +/- 50g, heating hot air circulation, with over-temperature and electric overload automatic power-off protection facilities, Temperature range RT +~ 200 ℃, designed according to GB4851 standard.
Factory-
CHINA NBC-5604 Tape holding tack Tester
$ 411.00 -
CHINA BLD-1006B 10 groups thermostatic retention testing machine
$ 1339.00 -
CHINA NBC-5604-10B thermostatic tape holding tack testing machine
$ 1330.00 -
PCZ-03 Lasting Adhesive Tester Three-station adhesive strength Tester
$ 598.00 -
JINGWEN JW207A-3p tape holding force testing machine, tape holding tack Tester 3 stations
$ 459.00
Introduction
It is designed and manufactured in accordance with GB 4851 (Pressure-sensitive adhesive tape stickiness test method) and plaster adhesion test method standards. It is suitable for pressure-sensitive adhesive tape, self-adhesive, plaster, hot melt and other products to conduct stickiness test tests.
Test principle
Hang the test plate with the adhesive sample attached vertically on the test frame, and hang a weight of specified weight at the lower end. Use the displacement of the sample to detach after a certain period of time, or the time for the sample to completely detach to characterize the adhesion test. The ability to resist pull-off. (as the picture shows)
design standards
GB 4851 Pressure-sensitive adhesive tape holding tack test method
JIS Z0237 Test methods for pressure-sensitive adhesive tapes and pressure-sensitive adhesive sheets ãã
ASTM D3654 Test Method for Shear Adhesion of Pressure Sensitive Tapes
How to operate
1. After removing the outermost 3 to 5 circles of adhesive tape from the adhesive tape test roll, unwrap the sample roll at a speed of about 300 mm/min (the isolation layer of the sheet sample is also removed at the same speed). Every 200mm or so, cut a sample 25mm wide and 100mm long from the middle of the adhesive tape. Unless otherwise specified, the number of specimens in each group shall not be less than three;
2. Use a wiping material dipped in cleaning agent to scrub the test board and loading board, then dry them carefully with clean gauze, and repeat cleaning three times. and above until the working surface of the board is clean upon visual inspection. After cleaning, do not touch the working surface of the board with your hands or other objects;
3. Under the conditions of temperature 23℃ ± 2℃ and Relative Humidity 65% ââ± 5%, according to the dimensions specified in Figure 2, stick the sample parallel to the longitudinal direction of the plate in the middle of the adjacent test plate and loading plate. Use a pressure roller to roll on the sample at a speed of approximately 300 mm/min. Note that when rolling, only the force generated by the mass of the roller can be applied to the sample. The number of rolling times can be specified according to the specific product conditions. If there is no stipulation, then it will be rolled back and forth three times;
4. After the sample is pasted on the board, it should be placed for 20 minutes at a temperature of 23℃ ± 2℃ and a Relative Humidity of 65% ± 5%. Then fix the test plate vertically on the test frame of the instrument and gently connect the loading plate and weight with pins.
5. Place the instrument horizontally, turn on the power switch, heating switch, and fan switch in sequence, and press the raised part on the timer to clear the time. The instrument automatically turns on according to the preset temperature until the temperature in the Test Chamber reaches the set value;ã
6. After the specified time is reached, remove the heavy objects. Use a magnifying glass with a graduation to measure the displacement of the sample when it slides down, accurate to 0.1mm; or record the time when the sample falls off the test plate. If the time is greater than or equal to 1h, the unit is min, and if it is less than 1h, the unit is s.
Factory NBC-5604-10B Thermostatic tape retention testing machineSpecifications
| LIST | VALUE |
|---|---|
| Number of measurement groups | 10 sets (independent Timer) |
| Standard press roller | 2000g±50g |
| Weight | 1000G +/- 10g (including loading plate Weight) |
| Test board | 50(L)mm×50(B)mm×1.5(D)mm |
| Automatic timer | 0~9999 hours, 59 minutes, 59 seconds can be switched |
| temperature control | Room temperature~ 70 ℃, PID control |
| Temperature display | 0.1 ℃ |
| Heating method | hot air circulation |
| Safety Devices | Equipped with over-temperature and electric overload automatic power-off protection facilities |
| Machine material | Internal SUS #304 stainless steel plate, external high-grade steel plate paint treatment |
| Volume (W * D * H) | 97×55×110cm |
| Weight | Paper 105KG |
| Power Supply | 1∮,AC220V, 15A |
Factory NBC-5604-10B Thermostatic tape retention testing machine Packing list
Host x1, test plate and loading steel plate each * 10 pieces, weight * 10 pieces, manual x1, manual pressure roller x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


NBC-5604-10B