KAIRDA F190 ° 90 ° Right Angle Probe Optional probe for NDT530 Coating Thickness Gauge
Measurement range 0~1250μm, error range +/- 3%, resolution 0.1mm, test environment magnetic metal matrix, overlay organic materials and other nonmagnetic overlay (such as: paint, lacquer, enamel, enamel, plastic and anode treatment, etc.).
KairDa-
German EPK probe N1.6/90 eddy current Thickness Gauge probe, thickness range 0~1600um
$ 2543.00 -
PUSHEN PIG Multipurpose Dry-Film Detector
$ 635.00 -
PHYNIX Surfix SX-F0.5A iron-based micro probe coated platings Thickness Gauge 500μm
Login -
Defelsko coating platings Thickness Gauge PosiTector 6000 N3 non-ferrous metal substrate (such as copper and aluminum) nonconductive coating
$ 1454.00 -
Defelsko NAS split thin coating probe
$ 1041.00
Introduction
KAIDA Coating Thickness Gauge NDT530 is a coating Thickness Gauge with a split structure design. It can be equipped with four different probes F1, N1, F10, and F1 90° to measure different coating thicknesses. Among them, F1, The F1 90° and F10 probes are used to measure the thickness of the non-magnetic coating on the magnetic metal substrate such as iron and steel, while the N1 uses the principle of eddy current to measure the thickness of the non-conductive coating on the non-magnetic metal substrate. One-point and two-point calibrations are available for all four probes.
Pictures






KairDa F1 Probe (90 ° right angle)Specifications
| LIST | VALUE |
|---|---|
| Measurement principle | magnetic induction |
| Measuring range | 0 ~ 1250µm |
| margin of error | ±3% |
| resolution | 0.1mm |
| Minimum measurement surface | F7mm |
| Minimum radius of curvature | 1.5mm |
| thinnest matrix | 0.5mm |
| Test environment | Magnetic metal matrix |
| overlay | Non-magnetic coatings such as organic materials (eg: paints, lacquers, enamels, enamels, plastics and anode treatments, etc.) |
KairDa F1 Probe (90 ° right angle) Packing list
Probe x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Measuring Color Difference in the Coatings Industry
- Hot Viscosity Testing FAQ - ASTM F1921
- Application Case of Adhesion Tester Gravure Ink Adhesion Test on PET Film Surface
- Tide Review: Adjustable Wet Film Coater ZUA2000.150
- Keshijia MG6-F1 Paint Gloss Meter Beauty Appreciation
- Comparison of key parts configuration list of XD-1JQ-A1 formaldehyde box and XD-1JQ-F1 formaldehyde box
- Influencing factors of waterborne Gravure ink gloss
- Appreciation of a set of beautiful pictures of TQC CC1000 scribe
- Uncertainty Evaluation and Influencing Factors Analysis of Coating Density Determination
- Light sources commonly used in color difference detection
- ActiveHG/T 3240-2007
- ActiveQJ 990.3A-2011
- ReplacedNF EN ISO 2808-2007
- ActiveGB/T 42541-2023
- ActiveGB/T 7991.5-2014
- ActiveISO 2178-2016
- ActiveASTM B499-2021
- ActiveISO 19840-2012
- ASTM E376-2019
- ActiveISO 2808-2019
- AbolishJJG 889-1995
- ActiveGB/T 4956-2003
- ISO 2361-1982
- ActiveGB/T 6463-2005
- AbolishGB/T 4956-1985
- AbolishASTM G12-07-2013
- ActiveJB/T 7663.2-2007
- ActiveJB/T 5000.12-2007
- AbolishGB/T 1764-1979
- ActiveGB/T 13452.2-2008