CHINA NBC-50L-40 programmable Humidity Chamber paint panel -40 ℃/50L
Appearance of baking paint, Japan Sanyo brand fully enclosed refrigeration compressor, temperature control -40 ℃~ 150 ℃, Interior size 350 * 300 * 500mm, multiple protection system, the main components are imported products, with 50mm test hole.
Factory-
Haiyoda Program Constant Temperature and Humidity Test Chamber, Humid Hot Box QT-E702-225B40 -40 ℃/225L
$ 2791.00 -
CHINA NBC-800L-60 Humidity chamber paint panel -60 ℃/800L
$ 5978.00 -
Lugong ST-50LB Humidity Chamber temperature cycle Test Chamber -40 ℃~ + 150 ℃
$ 2651.00 -
KESIONOTS KS-HW150E Low Temperature Constant Temperature and Humidity Chamber -50~ 150 ℃/150L
$ 4890.00 -
MODERNER HSX-150SC Constant Temperature and Humidity Chamber 10~45 ℃/150L
Login








Introduction
The high-low temperature and humidity alternating Test Chamber is mainly used to test the performance of materials in various environments and to test the heat resistance, cold resistance, dryness resistance and moisture resistance of various materials. Suitable for quality testing of electronics, electrical appliances, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical, aerospace and other products.
Control method: Using the Balanced Temperature and Humidity Control System (BTHC), the induction system transmits the actual data in the Test Chamber to the controller. The controller controls the SSR, multi-stage intelligent output, and balances the output power of the temperature and humidity system to ensure that the temperature and humidity in the Test Chamber are The temperature and humidity are fully stable, and it has an energy-saving function, which reduces the power usage of the instrument to a greater extent and ensures long-term accurate and stable operation of the instrument.
Features
1. The product has beautiful appearance, reasonable structure, precise technology, simple and convenient operation and stable and reliable performance.
2. The controller adopts a large color LCD human-machine touch dialogue LCD human-machine interface controller, which is simple to operate, easy to learn, stable and reliable, and displays complete system operating status, execution and setting program curves in Chinese and English, and can realize RS232 Computer interface docking, remote control of the instrument directly through the computer.
3. The refrigeration cycle system uses a compressor: an original imported Japanese "Sanyo" brand fully enclosed compressor (optional French Taikang compressor). All components are imported from Japan, France, the United States, Italy and other producing areas. Refrigeration The agent uses American environmentally friendly refrigerant (R23A, R404A).
4. There is a reserved test hole with a diameter of 50mm on the left side of the test box.
5. It has a fully automatic, high-precision system loop, any machine movement, PLC locking processing, all using PID automatic calculation control, and the temperature in the entire area has high precision and high stability.
6. Specially designed air circulation system and sensing system, the air outlet and return air sensor are detected and controlled to ensure the temperature uniformity in the Test Chamber and avoid any dead spots.
7. Adopt an enlarged observation window and 4 layers of tempered glass to provide a wider field of vision.
8. The instrument has a comprehensive protection system, including power overload protection, leakage protection, control loop overload, short circuit protection, compressor protection, grounding protection, over-temperature protection, alarm audible prompts, etc. When any abnormal situation occurs, the fault will be automatically displayed on the screen immediately. Point out the reason and automatically shut down.
Factory NBC-50L-40 (paint plate) Programmable Constant Temperature & Humidity Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Interior size | 350*300*500mm |
| Dimensions | 870*850*1370m |
| Temperature range | -40~150℃ |
| Temperature control Accuracy | ±0.1℃ |
| Temperature Fluctuation | ±0.5-1℃ |
| Temperature Uniformity | ±1.5-2℃ |
| Humidity control range | 20~98%R.H |
| Humidity Control Accuracy | ±0.1℃ |
| Humidity stability | ±1-2%R.H |
| Humidity Uniformity | ±1-3.0%R.H |
| Heating rate | 3 ℃/min nonlinear no-load |
| Cooling rate | 1 ℃/min (no-load nonlinear) |
| Total Weight | 130KG |
| operating Voltage | 220V/50HZ |
| Permissible Voltage Variation | ±10% |
| Maximum Power | 5kw |
| Inner box material | Mirror stainless steel plate (SUS #304) |
| Enclosure Material | Painted panel |
| top opening | Laser cutting and opening according to the test sample drawings provided by the customer |
| Insulation material | German Bayer polyurethane rigid foam + high density fiberglass |
| Shelf | 1 layer (punching treatment of high-strength SUS304 #stainless steel plate) |
| Maximum number of shelves | 4 layers (shelf spacing is adjustable) |
| Shelf Weight | 20KG |
| Test chamber door | Single door, double-decked door, left opening |
| test hole | A 50mm diameter test hole is opened on the left, and the durability, parcel and protection of the wiring harness far exceed that of domestic ordinary materials |
| Display | Imported 7-inch color touch screen display (touch screen operation control) |
| Temperature Resolution | ±0.1℃ |
| Humidity resolution | ±0.1%R.H |
| Temperature Control system | 9 groups of P.I.D control parameter setting, P.I.D automatic calculation |
| Ambient Temperature | 0~30℃ |
| Specification Environment | 5~25℃ |
| Environmental requirements | Miscellaneous items should not be placed within 60CM around the instrument, and the installation ground should not be severely tilted |
Factory NBC-50L-40 (paint plate) Programmable Constant Temperature & Humidity Test Chamber Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Humidity chamber core components dismantling: how to select compressors/Sensors
- Analytical magnetic material programmable Humidity Chamber, principle, application and selection
- Principle, application and selection of programmable Humidity Chamber for die casting
- Principle, application and selection of luggage Humidity Chamber
- Chip high-low temperature heat and humidity performance test
- Principle and Application Analysis of Fluorine Resin thermostatic Box
- Application of Humidity Chamber in building materials and flooring industry
- ActiveIEC
- ActiveIEC
- ActiveASTM
- IncomingGB/T 42125.4-2024
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveHG/T 5173-2017
- ActiveQX/T 16-2020
- ActiveGB/T 31467-2023
- ActiveGB/T 34120-2023
- ActiveGB/T 43489-2023
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 32065.6-2015
- ActiveQC/T 484-1999


NBC-50L-40 (paint plate)