CHINA NBC-225L-40 Programmable Humidity chamber -40 ℃
Temperature control -40 ℃, volume 225L, imported 7-inch color touch screen, imported Taikang compressor, nine-fold protection system, with automatic, high-precision system circuit, any part action.
Factory-
HUDA walk-in constant temperature and humidity test room QD-E705-12m ³ temperature control -40~80 ℃
$ 35977.00 -
ZKHS GDS-100C high-low temperature Humidity Test Chamber -40~150 ℃/100L
$ 6320.00 -
CHINA NBC-1000L-20 Laboratory high-low temperature constant temperature and humidity machine, paint panel -20 ℃/1000L
$ 4854.00 -
CHINA NBC-800L-20 programmable high-low temperature humidity cabinet testing machine, components resistant to humid heat -20 ℃/800L
$ 4439.00 -
YIHENG BPHS-060B High-low temperature Damping heat testing chamber -40~130 ℃/4150W
$ 4162.00








Introduction
The high-low temperature and humidity alternating Test Chamber is mainly used to test the performance of materials in various environments and to test the heat resistance, cold resistance, dryness resistance and moisture resistance of various materials. Suitable for quality testing of electronics, electrical appliances, communications, instruments, vehicles, plastic products, metals, food, chemicals, building materials, medical, aerospace and other products.
Control method: Using the Balanced Temperature and Humidity Control System (BTHC), the induction system transmits the actual data in the Test Chamber to the controller. The controller controls the SSR, multi-stage intelligent output, and balances the output power of the temperature and humidity system to ensure that the temperature and humidity in the Test Chamber are The temperature and humidity are fully stable, and it has an energy-saving function, which reduces the power usage of the instrument and ensures long-term stable operation of the instrument.
Features
The product has beautiful appearance, reasonable structure, precise technology, simple and convenient operation and stable and reliable performance.
The controller adopts a large color LCD human-machine touch dialogue LCD human-machine interface controller, which is simple to operate, easy to learn, stable and reliable, and displays complete system operating status, execution and setting program curves in Chinese and English, and can realize RS232 computer interface Docking, remote control the instrument directly through the computer.
The refrigeration cycle system uses a compressor: an original imported Japanese "Sanyo" brand fully enclosed compressor (optional French Taikang compressor). All components are imported from Japan, France, the United States, Italy and other production areas. The refrigerant is American environmentally friendly refrigerants (R23A, R404A).
There is a test hole with a diameter of 50mm reserved on the left side of the test box.
It has a fully automatic, high-precision system loop, any machine movement, PLC locking processing, all using PID automatic calculation control, and the temperature in the entire area has high precision and high stability.
The specially designed air circulation system and sensing system, with sensors detecting and controlling the air outlet and return air outlet, ensure the temperature uniformity in the Test Chamber and avoid any dead spots.
Adopting an enlarged observation window and 4 layers of tempered glass, the field of view is wider.
The instrument has a protection system, including power overload protection, leakage protection, control loop overload, short circuit protection, compressor protection, grounding protection, over-temperature protection, alarm audible prompts, etc. When any abnormal situation occurs, the fault point and cause will be automatically displayed on the screen. And automatically shut down.
The heating system adopts multi-section heating tubes and cooperates with the PID module to ensure temperature stability; segmented heating fully saves energy. The heating tube is made of high temperature resistant and corrosion resistant alloy tube to extend its service life.
The humidification system adopts a water quality filtration system to avoid clogging of the humidification system and reduce the frequency of cleaning. The circular split humidifier avoids the freezing phenomenon that occurs with Water Tank humidifiers during low temperature testing. The humidification tube is made of special alloy and can be dry-heated for more than 1 hour when the instrument fails and lacks water. With the high temperature alarm module, it effectively extends the service life of the humidification system. Built-in Water Tank and drawer-type water filling box are convenient and beautiful. Equipped with water circulation system, saving 40% water.
The pipelines used in the refrigeration system are all made of imported copper material. Its advantages are good flexibility, not easy to break, and good shock-absorbing effect on the long-term vibration characteristics of the refrigeration system.
The screen is an imported 7-inch color touch screen. Chinese and English can be switched at will. The backlight of the screen can be adjusted. The screen display protection function can be timed or manually turned off.
It has power-off program memory and can automatically start and resume program execution after power is restored.
Temperature and humidity curve control chart

Usage environment requirements
Allowable operating environment: 0 ~ 30℃.
Performance guaranteed environment: 5 ~ 25℃.
No other objects should be placed within 60CM around the instrument.
The installation ground must not be severely tilted.
Factory NBC-225L-40 Humidity chamberSpecifications
| LIST | VALUE |
|---|---|
| Temperature range | -40~+150℃ |
| Humidity range | 20% RH ~98% RH |
| control stability | Temperature: +/- 0.5-1 ℃; Humidity +/- 1-2% |
| distribution uniformity | Temperature +/- 1.5-2 ℃; Humidity +/- 1-3.0% |
| Heating rate | 3 ℃/min, non-linear no-load |
| Cooling rate | 1 ℃/min, non-linear no-load |
| temperature limit | Maximum temperature: + 150 ℃; Minimum temperature: -40 ℃ |
| Interior size | 600*500*750mm |
| Dimension | 1120*1050*1620mm |
| Weight | About 218KG |
| Inner box material | Mirror stainless steel plate (SUS #304) |
| Enclosure Material | Mirror stainless steel plate (SUS #304) |
| operating Voltage | 380V/50HZ |
| Permissible Voltage Variation | ±10% |
| Maximum Power | 12kw |
| frame structure | High-strength C-shaped steel is used as the main frame, and the static load on the top can reach 5000kg. |
| top opening | Laser cutting and opening can be carried out according to the test sample drawings provided by the customer |
| Insulation material | Using German Bayer polyurethane rigid foam + high density fiberglass |
| Heating system | Multistage heating pipe |
| Humidification system | Round split humidifier |
| condenser | Fin type multi-stage condenser with integral forced cooling fan |
| evaporator | Fin type multi-stage automatic load Capacity adjustment evaporator |
| refrigerant | R404A R23 |
| Freezing oil | American Ice Bear Frozen Oil |
| Drying Filter | Italian castor drying Filter |
| copper pipe | Using imported copper material |
| Air circulation system motor | High resistance air circulation motor |
| Air circulation system fan blade | Multi-wing fan blade |
| Shelf | 1 layer; single layer load 20KG |
| Test chamber door | Single door, double-decked door, left opening |
| handle | High Strength Deep Buckle Handle |
| hinge | High strength stainless steel |
| Sealing strip | High and low temperature resistant silicone sealing strip |
| defrost | Built-in hidden defrost line |
| test hole | 50Mm diameter test hole, located on the left side of the test chamber |
| data export | Equipped with USB data port |
| casters | High-load universal wheel * 4, located at the bottom of the instrument |
| Display | Imported 7-inch color touch screen display |
| language | Chinese and English display, can be switched arbitrarily. |
| operation control | Touch screen direct button type (touch screen operation control) |
| programmer | Temperature and Humidity Simultaneous Programmable Controller |
| Accuracy | Temperature +/- 0.1 ℃, Humidity +/- 1% R.H |
| resolution | Temperature +/- 0.1, Humidity +/- 0.1% R.H. |
| correction function | Automatic correction of wet and dry bulbs |
| Linear dispersion display | Humidity program setting value is displayed in graphic Linear dispersion, with real-time display program Linear dispersion execution function |
| Groups of programs available | Maximum 120 groups |
| Usable memory Capacity | A total of 1200 parts |
| Command, repeability | Each command can be up to 999 times |
| program function | With editing, clearing, inserting and other functions |
| SEGMENTS time setting | 0 ~ 99Hour59Min |
| Permissible environment | 0 ~ 30℃ |
| Specification Environment | 5 ~ 25℃ |
Factory NBC-225L-40 Humidity chamber Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Principle, application and selection of programmable Humidity Chamber for die casting
- Principle, application and selection of luggage Humidity Chamber
- Humidity cabinet test equipment
- Talking about the performance test of epoxy resin film coated on PET
- Damp heat testing chamber and low-Temperature Test Chamber
- Analytical magnetic material programmable Humidity Chamber, principle, application and selection
- Principle and Application Analysis of Fluorine Resin thermostatic Box
- Application of Humidity Chamber in building materials and flooring industry
- Damp heat testing chamber FAQ and solutions
- Chip high-low temperature heat and humidity performance test
- ActiveIEC
- ActiveIEC
- ActiveASTM
- IncomingGB/T 42125.4-2024
- ActiveGB/T 2423.34-2024
- ActiveJJF 1564-2016
- ActiveJJF 1270-2010
- ActiveJJF 1101-2019
- 2058-2023
- ActiveHG/T 5173-2017
- ActiveQX/T 16-2020
- Active 901-2021
- Active 10254-2022
- ActiveGB/T 31467-2023
- ActiveGB/T 34120-2023
- ActiveGB/T 43489-2023
- AbolishGB/T 2423.34-2012
- ActiveGB/T 2423.50-2012
- ActiveGB/T 32065.6-2015
- AbolishGB 15442.1-1995


NBC-225L-40