Varnishing BM-PH Phase Contrast Microscope
Using an electric light source, the luminance can be continuously adjusted, the hinged barrel is tilted 30 °, and can rotate 360 degrees freely.
SHSGBM-
ANYTY 3R-WM401PCST Microscope Bracket
$ 149.00 -
Varnishing BM-SG10PH Phase Contrast Microscope
$ 3843.00 -
TEELEN XTL-3230 Transmission reflection Polarizing Microscope
Login -
Zhongke Purui IPRE4XC Metallurgical Microscopy trinocular inverted, eyepiece magnification 10X
Login -
TEELEN SZ6000A Binocular Continuous Diploidy Microscope
Login
Introduction
Phase contrast microscopy is developed based on the principles of microscopic optical imaging and the theory of phase contrast microscopy technology. It is suitable for observation and research of low-contrast, non-stained living sample specimens in cytology, bacteriology, fresh blood specimens, aquatic plankton, etc.
The BM-PH trinocular phase contrast microscope uses an electric light source with continuously adjustable brightness. The hinged lens barrel is tilted at 30° and can rotate freely 360 degrees.
Standard configuration
eyepiece:
| type | gain | Visual field diameter |
| eyepiece | 10X | Ï18mm |
| 16X | Ï18mm |
Objective lens:
| type | gain | numerical aperture | working distance |
| achromatic objective lens | 4X | 0.1NA | 37.5mm |
| 10X | 0.25NA | 7.31mm | |
| 40X | 0.65NA | 0.63mm | |
| 100X (oil) | 1.25NA | 0.18mm | |
| phase contrast objective | 10X | 0.25NA | 7.31mm |
| 40X | 0.65NA | 0.63mm | |
| 100X (oil) | 1.25NA | 0.18mm |
SHSGBM BM-PH Phase Contrast MicroscopeSpecifications
| LIST | VALUE |
|---|---|
| Mechanical barrel length | 160mm |
| magnification | 40X-1600X |
| Stage size | Mobile platform 160 × 140mm Moving range: 80 × 50mm, cursor: 0.1mm |
| pupil distance | 53-75mm |
| Focusing device | 30 mm coarse fretting focusing coaxial mechanism, fine-tuning grid value 0.002mm |
| condenser | N.A.1.25 Adjustable medium Abbe condenser with variable light bar, phase contrast condenser with variable light bar |
| Color filter | Blue, yellow, green |
| Light source | Halogen lamp 6V20W, AC85V-230V adjustable luminance |
SHSGBM BM-PH Phase Contrast Microscope Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Overview of the different types of microscopes
- SP1100 Destructiveness Microscope Coating Thickness Gauge
- How to use X-4 series Melting point meter
- Galvanized coated Film thickness measurement
- Binocular Microscope Parts and Features
- What are the defects of optical microscopes? Industry common sense
- Instrument reference for preparation of aqueous PUA emulsion
- Microscope section measurement of coated Film thickness
- Microscope classification, operation and application
- Working Principle and Application Analysis of Confocal Microscope
- ActiveGB/T 44268.2-2024
- ActiveGB/T 44268.1-2024
- ActiveGB/T 44276.2-2024
- ActiveGB/T 44276.1-2024
- ActiveGB/T 44293-2024
- ActiveGB/T 39077-2024
- ActiveGB/T 43846.1-2024
- ActiveGB/T 43846.2-2024
- ActiveGB/T 43846.3-2024
- ActiveGB/T 13777-2024
- ActiveJB/T 8230.1-1999
- ActiveGB/T 10561-2023
- ActiveGB/T 42659-2023
- ActiveGB/T 42886-2023
- ActiveGB/T 22064-2008
- AbolishGB/T 22063-2008
- AbolishGB/T 22062-2008
- ActiveGB/T 22061-2008
- ActiveGB/T 22060-2008
- ActiveGB/T 2951.41-2008


BM-PH






