YINUO YN-MIT135 Computer MIT Folding Tester (New)
Measurement range 0~999999 times, folding angle unilateral angle: 135 ° (0~18 0 °) +/- 1 ° adjustable, man-machine interface 5.0inch color touch screen/Chinese and English dual system, can be set according to the test requirements of the sample vertical and horizontal, tension size, Test speed, folding times.
-
Essence LD-NZ-02 Folding Strength Tester, Folding Strength Tester, Touch Screen
$ 1585.00 -
Taichang TC-NZ135A Touch Screen MIT Folding Tester 0.25mm
$ 1485.00 -
CHINA BLD-105A EN sole folding testing machine
$ 1568.00 -
HUITAO HT-F817 Finished sole folding testing machine, national standard shoe bending testing machine
$ 7875.00 -
JINGWEN JW107C MIT Paper Folding Endurance Tester
$ 1446.00
Introduction
YN-MIT135 Computerized MIT Flexural Strength Tester is used to determine the bending resistance of paper fiber materials, the instrument is a single fold MIT type, which can set the longitudinal and transverse direction of the sample, the size of the tension, the test speed, and the number of folds according to the test requirements. It is mainly used for flexural strength testing of paper, fiber fabrics, metal sheets, plastic films and composite materials, and is suitable for paper packaging and printing industry, communication equipment wire manufacturing industry and related industry scientific research institutions and quality inspection departments.
Operating Principle
Fold resistance refers to the number of double folds that paper or cardboard can withstand reciprocating 135 degrees under a certain tension, and the number of double folds in the past or the number of double folds at the base of 10 is expressed as the numerical value, and the number of times used to record the breaking is the folding resistance.
According to the standard
GB/T457 、QB/T2679.5、ISO 5626
Features
5.0in touch screen display: Chinese and English can be switched freely;
The instrument is equipped with a variety of folding heads and weights, which can also be customized on demand;
It can be set horizontally and vertically, speed, angle, times, and tension can be adjusted;
Save the initial settings when the power is off, and automatically reset after the test is completed;
Panic button, you can control the process at any time in case of emergency;
Fully automatic measurement, intelligent judgment function, automatic shutdown of breakpoint to save data;
Independent suction ventilation and heat dissipation system, suitable for long-term fatigue test of internal heat;
It can be connected to a PC and automatically draw a graph of real-time test data (optional).
Test your app
| Test materials (Basic application) | use |
| Paper | It is suitable for flexural strength testing of paper and other materials such as base paper, printing paper, bobbin paper, etc |
| Corrugated cardboard | It is suitable for flexural strength testing of corrugated boxes, containerboard, corrugated cardboard and other materials |
| Aluminum foil, copper foil | It is suitable for flexural strength testing of copper foil, aluminum foil and other materials of a certain thickness |
| Fibrous material | It is suitable for flexural strength testing of glass fiber, carbon fiber and other materials |
| membrane | Flexural strength testing of optical films, composite films, superconducting films, and insulating separator materials |
| Flexible circuit boards | Flexural strength test of various FPC boards and circuit boards |
| Other materials | It is suitable for flexural strength testing of non-woven fabrics, fabrics, leather, and conductive materials |
YiNuo YN-MIT135 Computer MIT Folding Tester (new)Specifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~999999 times [logarithmic 0~ lg4.78] (the corresponding folding number can be set to automatically stop) |
| folding angle | Unilateral angle: 135 ° (0~18 0 °) +/- 1 ° adjustable, total angle back and forth: 0~360 ° adjustable |
| Tension adjustment | 4.91N/9.82N/14.73N (1~ 20N adjustable), spring compression at least 17mm |
| Standard upper chuck | Spiral locking fixture with specimen parallel position |
| Upper clamping thickness range | (0.1~2.30)mm |
| Upper clamping width range | (0.1~16.0)mm |
| Upper Clamping Force area | 7.8*6.60mm/51.48mm² |
| Upper clamping torque | 19.95:5.76—Wid 9.85mm |
| Parallel positioning height of specimen | 16.0mm |
| lower folding chuck | Tension change not more than 0.343N |
| The width of the lower folding head is | 19±0.1mm(0.1~20.0mm) |
| Lower clamping torque | 11.9:4.18~Wid 6.71mm |
| Reproducibility | 10%(when 30T), 8%(when 3000T) |
| Specimen length | ≥30mm |
| Upper and lower chuck distance | 20mm |
| The distance between the cracks of the folding mouth | 0.25, 0.5mm, 0.75, 1.00mm four sets of chucks |
| Human Machine Interface | 5.0Inch color touch screen/Chinese and English dual system |
| shutdown condition | Breaking automatic shutdown, setting the number of folding tests to reach shutdown, conduction fracture shutdown |
| Ventilating system | Self-priming cooling system, suitable for fatigue testing |
| printout | modular integrated thermal printer |
| Size Weight | 350*300*480mm |
| Weight | 35kg |
YiNuo YN-MIT135 Computer MIT Folding Tester (new) Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- The principle and test method of Schopper folding resistance Tester
- MIT refractometer test method
- FRANK horizontal refractometer test method
- Test method and principle of corrugated cardboard folding resistance meter
- What are the factors that affect folding endurance?
- What is the folding resistance of paper and cardboard?
- Analysis on the Application of Folding Tester in Cardboard
- How is the folding resistance Tester used for the detection of tissue paper?
- Plastic film folding resistance testing by folding resistance Tester
- Talking about the application of folding resistance Tester in metal foil


YiNuo
YN-MIT135
YN-MIT135