      Home> STIP-scan> HANNA> HANNA HI6321 Desktop Conductivity Meter

      HANNA HI6321 Desktop conductivity Tester

      A 7-inch capacitive touchscreen that supports multi-touch, stores a minimum of 1,000,000 data points per user, and friendly icons and symbols allow users to easily navigate and interpret instrument functions.

      Brand
      SKU: NB045243
      Italy HANNA
      Model
      VS
      Information
      Genuinegoods
      • HANNA HI6321 Desktop Conductivity MeterOverview

      • Specifications
      • Comments
      • FAQs
      HI6321
      Desktop Conductivity Meter
      • HANNA HI6321 Desktop conductivity Tester
      • HANNA HI6321 Desktop conductivity Tester Figure 1
      • HANNA HI6321 Desktop conductivity Tester Figure 2
      A 7-inch capacitive touchscreen that supports multi-touch, stores a minimum of 1,000,000 data points per user, and friendly icons and symbols allow users to easily navigate and interpret instrument functions.

      Introduction

      HI6321 is a streamlined desktop instrument with a large touch screen display, consisting of an instrument housing and an integrated conductivity measurement module. The HI6321 is compact and easy to operate and includes Hanna's HI7631233 four-ring conductivity/resistivity/TDS/salinity probe.

      Recommended for use in a wide range of industrial process water applications, the HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibration. An integrated temperature sensor measures the process temperature and adjusts the measured conductivity to the reference temperature by applying a specialized compensation algorithm:

      Linear: Applies when the temperature coefficient of variation is assumed to have the same value for all measured temperatures.

      Standard: Suitable for high-purity water measurement and documented in ASTM standard D5391-14. This setting applies to resistivity measurements greater than 1Mohm.cm.

      Natural: Applicable to natural groundwater, well water or surface water (or water with similar composition) that meets ISO7888 standards.

      TDS is a calculated value based on the conductivity of the solution (TDS = coefficient x EC25). The TDS factor is the conversion factor used to change EC measurements to ppm measurements.

      Sal psu: The actual salinity of seawater is related to the ratio of the conductivity of a normal seawater sample at 15℃ and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g/Kg at the same temperature and pressure. Under these conditions, the ratio is equal to 1 and S=35. Actual salinity levels are available for values ​​from 0 to 42.00 psu at temperatures from 0 to 35℃.

      Sal ppt: Measurements expressed in ppt are based on natural seawater grades of 0.00 to 80.00 g/L and cover a temperature range of 10 to 31℃. It determines the salinity based on the conductivity of the sample compared to standard seawater at 15℃ and the salinity value in seawater of approximately 35.

      Sal%: In this range, 100% salinity is equivalent to approximately 10% solids.

      Features

      user interface

      7-inch capacitive touch screen that supports multi-touch;

      capacitive touch screen, home and system menu keys;

      User-friendly icons and symbols allow users to easily navigate and explain instrument functions;

      Users can choose between five different views:

      • Simple GLP with calibration information.

      • Complete GLP with electrode status and calibration point details.

      • Interactive graphics that update in real time.

      • Tabular data containing date, time and comments.

      calibration

      Standard single-point salinity calibration of 100% salinity standard, with reading salinity scale set to %;

      Standard single or multiple conductivity calibration using standards;

      Non-volatile memory saves data and settings.

      Record

      Data log collection (with time and date stamp) of at least 1,000,000 data points;

      Logging type: manual, automatic, automatic retention;

      Manually and automatically maintain sample IDs for data.

      Connect features and services

      Transfer recorded data to USB drive;

      Includes log files of measurement and calibration data (as .csv files);

      FTP and email for log export via Ethernet and Wi-Fi connections;

      USB Type A, for USB flash drives, keyboards and printers;

      Type C USB for USB flash drive and PC connection.

      Instrument guide help section

      Video support demonstration of key features.

      VS

      HANNA HI6321 Desktop Conductivity MeterSpecifications

      LIST VALUE
      Resolution - conductivity EC 0.001 μS/cm, 0.01 μS/cm, 0.1 μS/cm, 0.001 mS/cm, 0.01 mS/cm, 0.1 mS/cm
      Measurement range - Electrical resistivity 1.0~99.9 Ω•cm; 100~999 Ω•cm; 1.00~9.99 KΩ•cm; 10.0~99.9 KΩ•cm; 100~999 KΩ•cm; 1.00~9.99 MΩ•cm; 10.0~100.0 MΩ•cm
      Resolution - Electrical resistivity 0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
      Measurement Accuracy - Electrical resistivity +/- 1 % ( +/- 1Ω • cm) of reading
      TDS range 0.000~9.999 ppm, 10.00~99.99 ppm, 100.0~999.9 ppm, 1.000~9.999 ppt, 10.00~99.99 ppt, 100.0~400.0 ppt (conversion factor 1.00)
      Resolution-TDS 0.001 ppm, 0.01 ppm, 0.1 ppm, 0.001 ppt, 0.01 ppt, 0.1 pp
      Measurement Accuracy - TDS +/- 1 % ( +/- 0.01 ppm) of reading
      Measurement range - salinity Actual salinity: 0.00~42.00 psu; Seawater salinity: 0.00~80.00 ppt; salinity percentage: 0.0~400.0%
      Resolution - salinity 0.01 (actual salinity, seawater salinity); 0.1% salinity
      Measurement Accuracy - salinity +/- 1% of reading
      Measurement range - temperature -20.0~120.0˚C
      Resolution - Temperature 0.1 °C
      Measurement Accuracy - temperature ±0.2 °C
      Calibrated point Automatic recommendation/user customization
      Standard calibrating fluid 84.00μS/cm,1.413mS/cm,5.000mS/cm,12.88mS/cm,80.00mS/cm,111.8mS/cm
      Reminder - conductivity calibrated Turn off function; Daily: 0 minutes to 23 hours 59 minutes; Period: 1 minute to 500 days, 23 hours 59 minutes
      Electrical resistivity calibrated By conductivity calibrated
      Salinity calibrated 1 calibrated point (percentage)
      Temperature compensation Automatic compensation or manual
      View type Direct/automatic hold
      Stability Accurate; medium; fast
      Sampling rate 1000 ms
      Icon (drawing) The relationship between pH (or mV) and temperature and time can be translated or scaled (Graduation technique).
      record type Automatic, manual recording, automatic maintenance
      Number of records Maximum of 50,000 data points per file; minimum of 1,000,000 data points per user
      automatic interval One, two, five, 10, 30 seconds; one, two, five, 10, 15, 30, 60, 120, 150, 180 minutes.
      Sample ID incremental mode
      Export options .Csv file format
      user Up to 9 users and administrators. Account (default)
      USB-A 2 ports for keyboard input or US-A driver
      USB-C 1 port for PC connection and USB-C drive
      Wi-Fi & Ethernet FTP; Web server log transfer and download; E-mail
      RS232 Connect peripheral devices
      Power DC Adapter 100-240AC, 24 VDC 2.5A
      Operating Environment 0 - 50.0 °C
      Size/Weight 205 x 160 x 77mm / ≈1.2kg

      HANNA HI6321 Desktop Conductivity Meter Packing list

      machine X1, manual X1, certificate X1, warranty card X1

      [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

      FAQ

      [Q]
      Is the price listed on the website the final cost for overseas purchases?
      [A]
      No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
      [Q]
      What is the specific process for purchasing the product?
      [A]
      First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
      [Q]
      What should I do if the instrument I purchase needs repair?
      [A]
      After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
      +HANNA HI6321 Desktop Conductivity Meter Big data
        +HANNA HI6321 Desktop Conductivity MeterKnowledge
        +HANNA HI6321 Desktop Conductivity MeterStandard
        +Navigation
        HANNA
        HANNA HI6321 Desktop conductivity Tester
        Service
        Focus on online sales of Lab Testing Instruments