      Home> STIP-scan> HANNA> HANNA HI2002 Desktop acidity meter

      HANNA HI2002 Desktop acidity meter pH-oxidation reduction ORP-temperature ℃ Tester

      Measurement range: pH-2.00 to 16.00pH, -2.000 to 16.000pH, temperature compensation, micro USB interface to achieve data transmission and charging functions to ensure further analysis and management of measurement data.

      Brand
      SKU: NB045245
      Italy HANNA
      Stock
      Loading…
      Price
      $ 719.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI2002 Desktop acidity meterOverview

        • Specifications
        • Comments
        • FAQs
        HI2002
        Desktop acidity meter
        • HANNA HI2002 Desktop acidity meter pH-oxidation reduction ORP-temperature ℃ Tester
        • HANNA HI2002 Desktop acidity meter pH-oxidation reduction ORP-temperature ℃ Tester Figure 1
        • HANNA HI2002 Desktop acidity meter pH-oxidation reduction ORP-temperature ℃ Tester Figure 2
        Measurement range: pH-2.00 to 16.00pH, -2.000 to 16.000pH, temperature compensation, micro USB interface to achieve data transmission and charging functions to ensure further analysis and management of measurement data.

        Introduction

        HI2002 ultra-thin microcomputer acidity pH-oxidation-reduction ORP-temperature ℃/℉ meter, 12.7mm ultra-thin body, 250g lightweight design, stylish and beautiful touch buttons, integrated screen and button design.

        Uniquely automatically identifies the electrode type and automatically enters the measurement project mode. The electrode sensor automatically stores calibration data and automatically retrieves and queries GLP stored data. The new CAL-CHECK™ electrode verification system prompts electrode contamination and standard buffer information to promptly remind acidity pH electrodes. Current status (good, good, damaged) and electrode connection status.

        Data management function, automatic storage of 1000 sets of data including measurement data, GLP data, time and date (interval: 200 sets of data storage; manual: 600 sets of data storage), USB data interface to realize measurement data output, micro USB interface to realize data Transmission and charging functions ensure further analysis and management of measurement data.

        Customized special bracket allows the electrode to be flexibly adjusted to a suitable measurement position and the display screen to be adjusted to a better Viewing Angle; it is ultra-light and easy to carry, and uses a touch-sensitive operation panel to effectively prevent damage to the operation panel by the sample. It is suitable for use in the laboratory, on-site or in the field. Quick measurement; customized special hanging bracket and host inlaid design, convenient and quick to hang the host on the wall, saving space and continuously charging the instrument through the power adapter, suitable for continuous and uninterrupted measurements.

        Features

        • Two USB interfaces: the USB host data interface realizes data output with the host, and the micro USB interface can perform data transmission and charging functions, which is convenient and fast;

        • Full-text mobile display: concise full-text information prompts are displayed at the bottom of the screen, eliminating troublesome abbreviations, making the operation more convenient and faster;

        • Dedicated charger and electrode bracket: Equipped with a charging interface edge base and an adjustable power loss bracket to protect the host and allow you to easily adjust the operating angle;

        • Capacitive touch keys: Stylish and beautiful touch keys, integrated screen and keys design, keeping you away from sample residue on the keyboard;

        • Data storage: 1000 sets of data storage including measurement data, GLP data, time and date;

        • Easy to see LCD: 5.5-inch large screen display, achieving 150° Viewing Angle range and clear readings from 5 meters away;

        • GLP Data Management: Last calibration information includes electrode impedance, slope, date, time and calibration point. Automatically identify edge acidity electrode;

        • Zero space occupation: wall-mounted design saves available space, and the base charging design is more user-friendly;

        • Built-in Basic mode: Users can use edge's built-in Basic mode to simplify measurement parameters and make the screen display more concise;

        • 3.5mm electrode interface: electrode connection is convenient and fast, with automatic identification;

        • CAL-CHECK function: In addition to the Hana CAL-CHECK function, which prompts electrode contamination and standard buffer information, it also adds a sensor Sensor Check function to promptly remind the pH electrode probe of damage and electrode connection status;

        • Stylish appearance: 1/2" (12.7mm) ultra-thin body, 0.8 ounce (250g) lightweight design.


        VS

        HANNA HI2002 Desktop acidity meterSpecifications

        LIST VALUE
        PH range -2.00 to 16.00pH, -2.000 to 16.000pH (standard mode)
        pH resolution 0.01 pH、0.001pH
        Accuracy @25 ℃/77 ° F pH ±0.001 pH、±0.01pH
        PH temperature compensation Automatic (ATC) temperature compensation, -5.0 to 100.0 ℃ (23.0 to 212.0 ° F)
        Electrode Diagnostic Mode - pH Standard diagnostic mode, detection electrode status, Response time, correction range, etc
        Calibration method -pH Three-point or five-point automatic calibrate recognition and two user-defined calibrates with built-in standard calibrate points (1.68, 3.00 or 4.01, 6.86, 7.01, 9.18, 10.01, 12.45pH)
        mV range ±1000mV
        mV resolution 0.1mV
        Accuracy @25 ℃/77 ° F -mV ±0.2mV
        ORP Measurement range ±2000mV
        ORP resolution 0.1mV
        Accuracy @25 ℃/77 ° F -ORP ±0.2mV(±999.9 mV)、±1mV(±2000mV)
        Calibration method -ORP Single point calibrated
        Measurement range -20.0 to 120.0℃(-4.0 to 248.0℉)
        Temperature Resolution & Accuracy Resolution: 0.1 ℃, 0.1 ° F; Accuracy : +/- 0.5 ℃, +/- 0.9 ° F
        Data storage Up to 1000 groups (basic mode: 400 groups) Data storage, manual point storage 200 groups Data storage; manual continuous 200 groups Data storage, time interval (up to 600 automatically, manual 100 samples storage)
        Electrode configuration HI11310 Built-in temperature sensor and amplifier Fillable Glass composite acidity electrode, 3.5mm Connector, 1m wire length
        Interface Standard USB interface, suitable for fast storage flash drive, Micro USB interface, suitable for data cable transmission and charging
        Operating Environment 0 to 50 ℃ (32 to 122 ° F), RH max 95%, non-condensing
        Power mode 230AC/5VDC power adapter
        Dimension 202*140*12mm
        Host Weight 250g

        HANNA HI2002 Desktop acidity meter Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +HANNA HI2002 Desktop acidity meter Big data
          +HANNA HI2002 Desktop acidity meterSimilar products
          +HANNA HI2002 Desktop acidity meterKnowledge
          +HANNA HI2002 Desktop acidity meterStandard
          +Navigation
          HANNA
          HANNA HI2002 Desktop acidity meter pH-oxidation reduction ORP-temperature ℃ Tester
          Service
          Focus on online sales of Lab Testing Instruments