      HANNA HI2003 Benchtop Conductivity Meter/Total Solid solubility/salinity/Temperature Meter

      Measurement range EC: 0.00 to 29.99 μ S/cm, the temperature compensation mode is automatic temperature (ATC) compensation, the electrode type is automatically identified, and the measurement item mode is automatically entered, and the electrode sensor automatically stores calibrated data.

      Brand
      SKU: NB045246
      Italy HANNA
      Stock
      Loading…
      Price
      $ 1081.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI2003 Desktop Conductivity MeterOverview

        • Specifications
        • Comments
        • FAQs
        HI2003
        Desktop Conductivity Meter
        • HANNA HI2003 Benchtop Conductivity Meter/Total Solid solubility/salinity/Temperature Meter
        • HANNA HI2003 Benchtop Conductivity Meter/Total Solid solubility/salinity/Temperature Meter Figure 1
        • HANNA HI2003 Benchtop Conductivity Meter/Total Solid solubility/salinity/Temperature Meter Figure 2
        Measurement range EC: 0.00 to 29.99 μ S/cm, the temperature compensation mode is automatic temperature (ATC) compensation, the electrode type is automatically identified, and the measurement item mode is automatically entered, and the electrode sensor automatically stores calibrated data.

        Introduction

        HI2003 desktop conductivity meter is a newly launched ultra-thin microcomputer conductivity-total solid solubility-salinity-temperature measuring instrument, which is an excellent work of design capabilities, product integration, and R&D teams.

        Features

        • Powerful management functions: automatically identify electrode types, automatically enter measurement project mode, and automatically store calibration data for electrode sensors.

        • Data management function: 1000 sets of data including measurement data, GLP data, time and date are automatically stored (interval: 200 sets of data storage; manual: 600 sets of data storage), USB data interface realizes measurement data output, micro USB interface realizes Data transmission and charging functions ensure further analysis and management of measurement data.

        • Ultra-large screen, on-screen operation step prompts: 5.5-inch ultra-large screen display, achieving a 150° Viewing Angle range and clear readings from 5 meters away; concise full-text information prompts are displayed at the bottom of the screen, eliminating troublesome abbreviations, making operations more convenient and faster.

        • Ultra-thin design, touch operation: 12.7mm ultra-thin body, 250g lightweight design, stylish and beautiful touch buttons, integrated screen and button design, keeping you away from sample residue on the keyboard. The three-in-one design of laboratory desktop, wall-mounted, and handheld models saves available space, and the base charging design is more user-friendly.

        • 3.5mm digital electrode interface, more convenient and faster operation: equipped with HI763100 customized built-in temperature sensor four-ring EC/TDS digital electrode, the electrode body has a built-in micro memory chip, which can automatically identify the electrode type, ID and calibration details when connected to the host.

        VS

        HANNA HI2003 Desktop Conductivity MeterSpecifications

        LIST VALUE
        EC range 0.00 to 29.99 μS/cm, 30.0 to 299.9 μS/cm, 300 to 2999 μS/cm; 3.00 to 29.99 mS/cm, 30.0 to 200.0 mS/cm; up to 500.0 mS/cm (actual/absolute conductivity, closing temperature compensation)
        Resolution-EC 0.01μS/cm、0.1μS/cm、1μS/cm、0.01 mS/cm、0.1 mS/cm
        Accuracy @25 ℃ -EC +/- 1 % +/- ( 0.05 μS/cm or 1 word), whichever is larger
        Calibrated mode - EC Automatic calibration of 0.00μS/cm in the air under electrode drying; built-in standard calibrating point automatic identification and calibrating; built-in calibrating point: 84μS/cm, 1413μS/cm, 5.00mS/cm, 12.88mS/cm, 80.0mS/cm, 118.8mS/cm
        TDS range 0.00~14.99 mg/L (ppm), 15.0~149.9mg/L (ppm), 150~1499mg/L (ppm); 1.50~14.99g/L, 15.0~100.0g/L; up~ 400.0g/L (actual/absolute total solids solubility, closing temperature compensation), TDS conversion factor: 0.80
        Resolution-TDS 0.01mg/L(ppm)、0.1mg/L(ppm)、1mg/L(ppm)、0.01g/L、0.1 g/L(ppt)
        Accuracy @25 ℃ -TDS +/- 1 % +/- ( 0.03mg/L or 1 word), whichever is greater
        Calibrated Mode - TDS Conductivity Detector calibrated without total solids solubility
        TDS conversion factor 0.45~ 0.80 adjustable (default 0.5)
        Salinity range Actual salinity: 0.00~42.00 PSU, seawater salinity: 0.00~80.00ppt (g/L); salinity: 0.0~400.0% NaCl
        Salinity resolution 0.01 PSU、0.1g/L、0.1%
        Salinity Accuracy @25 ℃ Reading +/- 1%
        Salinity calibrated mode PSU and g/L salinity units do not need to be calibrated according to conductivity calibrating results;% units can optionally be calibrated with HI7037 salinity standard buffer (100%)
        Temperature measurement Accuracy ±0.5℃、±0.9°℉
        Electrode type HI763100 Customized built-in temperature transducer EC/TDS special electrode, Interface type: 3.5mm, 1 meter wire length
        Temperature compensation Automatic temperature (ATC) compensation, -5~ 100 ℃ (32~ 212 ° F); when measuring absolute conductivity, select off temperature compensation (NOTC)
        compensation coefficient Conductivity temperature coefficient range: 0.00~6.00%/℃
        GLP Calibrated data includes information such as date, time and calibrated point
        storage mode Automatically store 1000 sets of measurement data, store 200 sets of measurement data at intervals; manually store 600 sets of measurement data
        Interface Dual communication interface mode: USB Interface and micro Interface
        Power mode Built-in rechargeable battery, 5VDC power adapter and special charging multi-function bracket
        Operating Environment 0 to 50℃(32 to 122 F)
        Size Weight Host size: 202x140x12.7mm, host Weight: 250g

        HANNA HI2003 Desktop Conductivity Meter Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        HANNA
        HANNA HI2003 Benchtop Conductivity Meter/Total Solid solubility/salinity/Temperature Meter
        Service
        Focus on online sales of Lab Testing Instruments