HANNA HI8733 Conductivity Meter Conductivity Detector electrode design
Configuration electrode HI76302W built-in temperature transducer four-ring conductivity electrode, manual/automatic temperature compensation function, excellent waterproof performance suitable for production, quality control experiment site use.
HANNA-
FANGZHOU DDS-302 + high-precision pure water conductivity meter
$ 747.00 -
HANNA HI7031L Conductivity Detector calibrating liquid 1413μS/cm
$ 117.00 -
DDKSIC CON201G Conductivity Detector electrode for laboratory and outdoor measurement of conventional water samples
$ 112.00 -
DDKSIC DJS-0.01VK Low Range Conductivity Detector electrode set for pure water, ultrapure water distillation water, etc
$ 174.00 -
BANTE A150-UK Laboratory conductivity /TDS/salinity/resistivity meter
$ 626.00
Introduction
Conventional conductivity (EC) meters using galvanic systems often require recalibration and measurements with different electrodes, resulting in extended measurement times and unreliability. The four-ring conductivity electrode of the HI8733 conductivity meter solves this problem. Only one electrode is needed to complete multi-range measurements. The electrode is made of PVC material and is suitable for field measurements. The instrument adopts single-point calibration and can obtain accurate readings in a wide range of 0.0 to 199.9 mS/cm.
HANNA's special four-ring conductivity electrode only needs one electrode to complete multi-range measurements. The electrode is made of PVC material and is suitable for field measurements. It has a new appearance design, a large screen display, and four ranges for quick manual selection. The instrument adopts single-point calibration. Freely select and set calibration points; humanized operation interface, simple and convenient operation; automatic temperature compensation to ensure measurement accuracy and accuracy in different environments; suitable for providing laboratory-level measurement results in harsh environments. Good value for money.
Features
New appearance design, backlit large-screen LCD display;
Manual/automatic temperature compensation function, manual selection of range;
Manual single-point calibration, calibration is convenient and accurate;
Adopting new microcomputer technology, specially designed for on-site measurement;
Excellent waterproof performance is suitable for use in production and quality control experiments;
Samples in different concentration ranges can be measured, from deionized water to brine.
HANNA HI8733 Conductivity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.0~199.9μS/cm、0~1999μS/cm、0.00~19.99mS/cm、0.0~199.9mS/cm |
| Resolution | 0.1μS/cm、1μS/cm;0.01mS/cm、0.1mS/cm |
| Accuracy | (@25 ℃/77 ° F) +/- 1% of the reading (ignoring probe errors) |
| Calibrated mode | Manual single point calibrating (based on the water sample prediction data, select a relatively similar conductivity standard buffer) |
| Temperature compensation | Manual temperature compensation: 0.0 - 50.0 ℃ compensation factor 2.0%/℃; Automatic temperature compensation: 0.0 - 50.0 ℃ compensation factor 0.0-2%/℃ adjustable |
| Configuration electrode | HI76302W Four-ring conductivity electrode with built-in temperature transducer, DIN interface, 1m line length |
| Battery model and lifespan | 9V AA battery |
| Operating Environment | 0 to 50°C(32 to 122°F);RH max 100% |
| Size/Weight | 145×80×36mm/230g |
HANNA HI8733 Conductivity Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI8733
HI8734