HANNA HI98301 conductivity EC/TDS total solid solubility Measurement Instrument
Measurement range 0~2000 ppm (mg/L), resolution 1ppm (mg/L), accuracy @25 ℃ +/- 2% F.S., waterproof design, suitable for drinking water, water treatment, reverse osmosis (RO) process, chilled down tower water quality, printing industry, etc.
HANNA-
Bante DB2-3 economical Chinese screen Portable Conductivity Meter conductivity temperature
$ 274.00 -
HANNA HI98312 High Range EC-TDS- ℃ Meter
$ 267.00 -
HANNA HI7031L Conductivity Detector calibrating liquid 1413μS/cm
$ 117.00 -
FANGZHOU FZ-704W Conductivity Detector electrode (platinum black) 200µs/cm-200mS/cm
$ 133.00 -
Bante510-S Laboratory conductivity /TDS meter
$ 293.00
Introduction
HI98301 conductivity meter adopts a new appearance design, a large two-line screen display, easy operation, automatic identification of single point [standard point @25℃: 1382 ppm (mg/L) [HI7032 recommended] identification calibration, automatic temperature compensation, automatic single point Point calibration, calibration is convenient and accurate, ensuring the reliability of measurement data and measurement data. The compact design of the novel temperature probe and graphite electrode, good temperature compensation, improved electrode response time and measurement accuracy, good indication marks, and good control of the depth of the electrode immersed in the water sample. It is suitable for different industries such as food and beverage, water treatment, and environmental analysis.
Features
Waterproof design, large screen LCD;
Automatic temperature compensation function, automatic calibration of 1 calibration point;
Test data is displayed stably;
External temperature sensor for temperature detection;
Suitable for drinking water, water treatment, reverse osmosis process, cooling tower water quality, sewage, laboratory, agriculture, aquaculture, aquarium, agricultural cultivation, printing industry, etc.
HANNA HI98301 Conductivity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~2000 ppm(mg/L) |
| resolution | 1 ppm(mg/L) |
| Accuracy @25 ℃ | ±2% F.S. |
| Temperature range | 0.0~50.0℃ / 32.0~122.0℉ |
| Temperature Accuracy @25 ℃ | ±0.5℃~1.0℉ |
| Calibrating liquid | HI70032(1382ppm) |
| Calibrate | Automatic calibration |
| Temperature compensation | Automatic compensation 0~50 ℃/32~ 122 ° F range |
| Environment | 0~50℃ / 32~122℉ |
| size | 40*160*17mm |
| Weight | 75g |
HANNA HI98301 Conductivity Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJG 2059-2014
- ActiveJB/T 9366-2017
- ActiveHJ 802-2016
- ActiveDL/T 1602-2016
- ActiveDL/T 1207-2013
- ActiveJB/T 13940-2020
- ActiveSL 78-1994
- Active 10827-2021
- ActiveGB/T 1576-2018
- ActiveGB/T 12582-1990
- ActiveGB/T 13580.3-1992
- ActiveGB/T 6539-1997
- AbolishGB/T 17650.2-1998
- ActiveGB/T 18932.15-2003
- AbolishGB/T 12966-2008
- ActiveGB/T 11007-2008
- ActiveGB/T 23246-2009
- ActiveGB/T 23595.6-2009
- ActiveGB/T 23977-2009
- ActiveGB/T 20245.3-2013


HI98301