HANNA HI98193 dissolved oxygen DO-biochemical oxygen demand BOD Tester
Large range, dissolved oxygen 50.00 mg/L (ppm), saturated dissolved oxygen 600.0%, measurement of dissolved oxygen, saturated dissolved oxygen, atmospheric pressure, temperature A number of important water index measurement dissolved oxygen can be directly converted BOD, OUR, SOUR measurement results.
HANNA-
TONGAO TR-102H Portable Cyanide Tester 0-1mg/L
$ 786.00 -
BANTE 502 ORP electrode for measurement of weak Oxidation-reduction potential
$ 158.00 -
JINGQI WD9102P Total Phosphorus Tester with Printing Function
$ 1305.00 -
TONGAO TR 6900NHP STIP-scan detection of ammonia nitrogen/Total phosphorus/turbidity/suspended solids
$ 2651.00 -
Bante40 Portable Smart Water Hardness Meter 0.05~ 200mmol/L
$ 815.00
Introduction
The HI98193 is a portable DO meter with extended range up to 50 ppm and 600% saturation. The HI98193 features pressure, temperature and salinity compensation, which is critical for accurate dissolved oxygen readings. HI98193 is equipped with HI764073 polarographic dissolved oxygen probe with field-replaceable PTFE membrane cap.
Biochemical oxygen demand (BOD, biochemical oxygen consumption)
The amount of dissolved oxygen consumed by microbial metabolism is an important indicator to indirectly express the degree of water body pollution by organic matter. It is defined as: the amount of free oxygen consumed by aerobic microorganisms to oxidize and decompose organic matter per unit volume of water under aerobic conditions. , the unit is expressed in ppm (mg/L). The higher the value, the more organic pollutants in the water and the more serious the pollution.
The international standard is to measure biochemical oxygen demand by cultivating for 5 days in an Incubator set at 20℃, which is the five-day biochemical oxygen demand (BOD5).
Oxygen consumption rate (OUR, oxygen uptake rate)
Oxygen consumption rate determines the oxygen consumption rate of activated sludge to analyze whether it contains non-toxic substances, load conditions and sludge balance to better set up and control the sewage treatment process.
Specific oxygen consumption rate (SOUR)
It is a quantitative index for evaluating the stability of activated sludge in sewage treatment. It refers to the oxygen consumption per unit mass of activated sludge in unit time; SOUR is an important biochemical index in experimental studies such as microbial culture. The SOUR (respiratory intensity) of microbial cells refers to the amount of oxygen consumed by cells per unit weight in unit time.
Characteristics
IP67 waterproof, sturdy shell;
Salinity compensation allows direct determination of dissolved oxygen in salt water;
Automatic temperature compensation, capable of one or two-point temperature calibration;
Automatic air pressure compensation, 1-point calibration;
Built-in calculations, determination of biochemical oxygen demand (BOD), oxygen uptake (OUR) and specific oxygen uptake (SOUR);
The probe automatically polarizes when started;
Approximately 200 hours of continuous use;
Clear display, dot matrix display, with multi-function virtual keys;
AutoHold, automatically holds the first stable reading on the display;
Calibration timeout, which triggers an alarm when calibrating at a specified interval;
PC connection via optically isolated micro USB with HI92000 software;
Log in on demand and store measurement data at the push of a button;
GLP data provides calibration data including date, time, pressure, calibration value, temperature and salinity values ââof last calibration.
HANNA HI98193 Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| Dissolved oxygen Measurement Range | 0.00-50 mg/L (ppm); 0.0-600% saturation |
| Resolution of dissolved oxygen | 0.01Mg/L (ppm); 0.1% saturation |
| Dissolved oxygen calibrate | Automatically at one or both points of 100% (8.26mg/L) and 0% (0mg/L); manually, using the value entered by the user in% saturation or mg/L |
| Atmospheric pressure Measurement Range | 450-850mmHg |
| atmospheric pressure resolution | 1mmHg |
| Atmospheric pressure calibrated | A point in any range of pressure values |
| Temperature Measurement Range | -20.0-120.0℃;-4.0-248.0°F |
| temperature resolution | 0.1℃;0.1°F |
| Temperature Accuracy (@25 ℃/77 ° F) | +/- 0.2 ℃; +/- 0.4 ° F (excluding probe errors) |
| Temperature calibrated | The temperature value of one or two points in any range |
| Measurement mode | Direct DO; BOD (Biochemical Oxygen Demand); OUR (Oxygen Absorption); SOUR (Specific Oxygen Uptake) |
| Air pressure compensation | Automatic from 450-850mmHg |
| Salinity compensation | Automatic, from 0-70g/L |
| Temperature compensation | Automatic from 0.0-50 ℃ (32.0-122 ° F) |
| Probe | HI764073 Polarographic DO probe with protective sleeve internal temperature transducer, DIN Connector and 4m (13 ') cable (included) |
| logging | Log up to 400 samples on demand |
| PC connection | Optical isolation USB (with HI92000 software) |
| Battery type/lifespan | 1.5V (4) AA battery/no backlight for about 200 hours of continuous use (about 50 hours with backlight) |
| Automatic shutdown | User can choose: 5, 10, 30, 60 minutes or disable |
| Environment | 0-50℃(32-122°F);RH 100% IP67 |
| size | 185x93x35.2mm(7.3x3.6x1.4") |
| Weight | 400g(14.2 oz.) |
HANNA HI98193 Dissolved Oxygen Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 1714-2018
- ActiveJJF 1565-2016
- ActiveJJF 1441-2013
- ActiveJJG 2104-2024
- ActiveJB/T 14242-2022
- ActiveHJ 925-2017
- Active 096-2007
- ActiveSC/T 7006-2001
- AbolishGB/T 12157-2007
- ActiveGB/T 20245.4-2013
- ActiveGB/T 12157-2022
- ActiveGB/T 7489-1987
- ActiveGB/T 11913-1989
- ActiveGB/T 18920-2020
- ActiveGB/T 1576-2018


HI98193