HANNA HI98713 Microcomputer multi-range Turbidimeter (ISO standard)
Measurement range 0.00 to 1000 FNU, resolution 0.01 FNU (≤ 9.99), 0.1FNU (≤ 99.9), 1FNU (≤ 1000), 200 sets of measurement Data storage devices, powerful CALCHECK Check Adjustment, suitable for different concentration samples in different fields.
HANNA-
Qiwei WGZ-200B Precision Portable Dual Range Turbidity Meter 0-20NTU/0-200NTU
$ 225.00 -
INESA WGZ-200B Portable Turbidity Meter 200NTU
$ 444.00 -
Yuefeng SGZ-20A Turbidity Meter 0~20NTU/0.01
$ 207.00 -
Yuefeng SGZ-4000IT Microcomputer Turbidity Meter 4000NTU/0.001
$ 1174.00 -
Yuefeng SGZ-200A interface Turbidity Meter with printing interface
$ 366.00
Introduction
Hl98713 is a high-precision multi-range portable Turbidimeter with different measurement range options, low turbidity range (0.00 to 9.99FNU) and high turbidity range (100 to 1000FNU), especially in the low value range with extremely high The accuracy and precision are suitable for the measurement of samples with different concentrations in different fields.
It complies with the 1S07027 turbidity measurement standard and has a powerful CALCHECK calibration function. It uses Hl98713-11 turbidity calibration set (turbidity scale value: â¤0.10, 15, 100, 750 FNU/NTU) to effectively check the instrument. Calibration ensures the accuracy and reliability of the instrument.
TIS electronic label (Fast Trackerâ¢) automatic identification data system
The installation and operation of the TIS Electronic Tag Identification Management System (Fast Trackerâ¢) is very simple. Just attach the iButton to the sample to be tested. When measuring the sample to be tested, after storing the data, press the instrument and it will prompt you to enter the electronic tag code; as long as the instrument is By docking with the electronic tag, the code of the sample to be tested and the measured star value of the corresponding electronic tag can be displayed. Through USB or RS232 data interface and customized special data processing software, the stored data can be transferred to the computer, and multiple standards can be set to analyze the data as needed, including filtering of sampling points, dates, measurement ranges, etc., and curves can be drawn based on the measurement data. Graph or print results.
Characteristics
Large backlit LCD display, stable indicator signs, and on-screen operation prompts;
GLP management function, query settings, calibration, time and other information;
Multi-range measurement, automatic range conversion;
IR LED special infrared light source, compliant with 1S07027 standard;
USB-RS232 dual data interface, 200 sets of data storage.
HANNA HI98713 Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement mode | Automatic range conversion; ordinary measurement, continuous measurement, average measurement |
| Measurement range | 0.00 to 9.99、10.0 to 99.9、100 to 1000 FNU |
| resolution | 0.01 FNU(≤9.99)、0.1FNU(≤99.9)、1FNU(≤1000) |
| Measurement Accuracy | Reading +/- 2% + 0.1 FNU @25 ℃/77 ° F |
| repeatability | +/- 1% of the reading or 0.01 FNU, whichever is greater |
| minimum detection | <0.1 FNU |
| Method standard | Turbidity measurement method (90 ° & 180 °), in accordance with ISO7027 turbidity measurement standard |
| Calibrated mode | Manual calibration, built-in 4-point calibrating points: < 0.1, 15, 100, 750FNU |
| data management | USB-RS232 Dual Interface, 200 sets of measurement Data storage |
| Power mode | 4 × 1.5V AA battery; will automatically shut down without any operation for 15 minutes |
| Adapt to the environment | 0°C to 50°C;max 95% RH 无冷凝 |
| Size Weight | Host size: 224 × 87 × 77 mm, Host Weight: 512g |
HANNA HI98713 Turbidity Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- Active 100-2007
- ActiveDIN EN ISO 15715-2006
- ActiveGB/T 13531.3-1995
- ActiveGB/T 13200-1991
- ActiveGB/T 1576-2018


HI98713
HI98703