HANNA HI98703 Microcomputer multi-range Turbidimeter (EPA standard)
Measurement range 0.00 to 1000 NTU, measurement accuracy reading +/- 2% + 0.02 NTU, with GLP management function, multi-range measurement, automatic range conversion, widely used in thousands of water quality monitoring, wastewater and other fields, can be used on-site portable or laboratory desktop use.
HANNA-
JINGQI WGZ-1000B Portable precision low turbidity instrument
$ 640.00 -
INESA INESA WGZ-200 Benchtop Turbidity Meter 200NTU
$ 630.00 -
Yuefeng SGZ-800IT Microcomputer Turbidity Meter 800NTU/0.001
$ 599.00 -
Yuefeng SGZ-1000BS Portable Turbidity Meter 0~1000NTU/0.1
$ 472.00 -
Yuefeng SGZ-50A interface Turbidity Meter with printing interface
$ 316.00
Introduction
Portable high-precision, multi-range Turbidimeter. The large sample cuvette is matched with an excellent optical system. The microprocessor calculates the turbidity value through the light intensity reaching the photoDetector; it effectively corrects color interference and has chromaticity compensation and automatic light source compensation functions to avoid light source fluctuations. interference caused, no need for frequent calibration. It is especially suitable for high-precision measurement of low-range turbidity. It is widely used in water quality monitoring, wastewater and other fields. It can be used on-site as a portable or laboratory desktop.
The installation and operation of the TIS Electronic Tag Identification Management System (Fast Trackerâ¢) is very simple. Just attach the iButton to the sample to be tested. When measuring the sample to be tested, after storing the data, press the instrument and it will prompt you to enter the electronic tag code; just attach the iButton to the sample to be tested. When the instrument is connected to the electronic tag, the code and measurement value of the sample to be tested corresponding to the electronic tag will be displayed. Through the USB or RS232 data interface and customized special data processing software, the stored data can be transferred to the computer, and multiple standards can be set to analyze the data as needed, including filtering of sampling points, dates, measurement ranges, etc., and drawing based on the measurement data Graph or print results.
Characteristics
Large backlit LCD display, stable indicator marks, and on-screen operation prompts;
GLP management function, query settings, calibration, time and other information;
Multi-range measurement, automatic range conversion;
USEPA180.1 standard and Standard Method 2130B method;
USB-RS232 dual data interface, 200 sets of data storage, data management.

HANNA HI98703 Turbidity MeterSpecifications
| LIST | VALUE |
|---|---|
| Measurement mode | Automatic range conversion; ordinary measurement, continuous measurement, average measurement |
| Measurement range | 0.00 to 9.99、10.0 to 99.9、100 to 1000 NTU |
| resolution | 0.01 NTU(≤9.99) 0.1NTU(≤99.9) 1NTU(≤1000 |
| Measurement Accuracy | Reading +/- 2% + 0.02 NTU @25 ℃/77 ° F |
| Turbidity Repeatability | +/- 1% of the reading or 0.02 NTU, whichever is greater |
| minimum detection limit | <0.02 NTI |
| Method/standard | Turbidity (90 °) or scattering turbidity (90 ° & 180 °) conforms to USEPA Method 180.1 and Standard 2130B |
| Calibrated mode | Manual calibration, built-in 4-point calibrated points: < 0.1, 15, 100, 750NTU |
| data management | USB-RS232 Dual Interface, 200 sets of measurement Data storage |
| Power mode | 4 × 1.5VAA battery; 15 minutes without any operation, it will automatically shut down. |
| Adapt to the environment | 0°C to 50°C;max 95% RH 无冷凝 |
| Size Weight | Host size: 224 × 87 × 77mm, Host Weight: 512g |
HANNA HI98703 Turbidity Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.