      HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard)

      Using EPA custom Light source, in line with USEPA180.1 standard and Standard Method2130B standard method, using EPA custom Light source, suitable for water treatment, scientific research institutions, food and beverage, environment analysis and other industries.

      Brand
      SKU: NB045263
      Italy HANNA
      Model
      Stock
      Loading…
      Price
      $ 3250.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI83414 Turbidity MeterOverview

        • Specifications
        • Comments
        • FAQs
        HI83414
        Turbidity Meter
        • HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard)
        • HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard) Figure 1
        • HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard) Figure 2
        Using EPA custom Light source, in line with USEPA180.1 standard and Standard Method2130B standard method, using EPA custom Light source, suitable for water treatment, scientific research institutions, food and beverage, environment analysis and other industries.

        Introduction

        HI83414 is a high-precision multi-parameter laboratory analyzer that cleverly combines the measurement of three parameters: turbidity, residual chlorine, and total chlorine. It is a multi-functional all-in-one machine suitable for the drinking water industry. It has different measurement range options and low turbidity. Measuring range (0.00to40.00NTU) and high turbidity range (0.00to4000NTU), especially in the low value range, have high accuracy and accuracy, and are suitable for the measurement of samples with different concentrations in different fields.

        H183414 adopts EPA's special customized light source, complies with USEPA180.1 standard and Standard Method2130B standard method. It has powerful CALCHECK chlorine calibration function and is suitable for different industries such as water treatment, scientific research institutions, food and beverage, and environmental analysis; multi-range, multi-project Measurement, automatic range conversion, selection of different measurement units (NTU, Nephelos, EBC) and different measurement ranges meet various needs in different fields and guarantee measurement accuracy.

        Characteristics

        • Multi-range, multi-item measurement, automatic range conversion;

        • USEPA standard and Standard Method 2130B method;

        • Residual chlorine-total chlorine has the CAL CHECK performance verification function;

        • GLP management function, query settings, calibration, time and other information;

        • 2, 3, 4, and 5-point manual calibration, built-in 5-point turbidity calibration points;

        • USB data interface, 200 sets of data storage, good data management.

        VS

        HANNA HI83414 Turbidity MeterSpecifications

        LIST VALUE
        Measurement range - turbidity nonlinearity 0.00 to 9.99 NYU、10.0 to 40.0 NTU、0.0 to 99.9 Nephelos、100 to 268 Nephelos、0.00 to 9.80 EBC
        Resolution - turbidity nonlinearity 0.01 NTU、0.1NTU;0.1 Nephelos、1 Nephelos;0.01EBC
        Measurement Accuracy - turbidity nonlinearity Reading +/- 2% + 0.02 NTU (0.15 Nephelos; 0.01 EBC), (@25 ℃/77 ° F)
        Measurement range - turbidity linearity 0.00 to 9.99 NTU、10.0 to 99.9NTU、100 to 4000 NTU、0.0 to 99.9 Nephelos、100 to 26800 Nephelos 0.00 to 9.99EBC、10.0 to 99.9 EBC、100 to 980EBC
        Resolution - turbidity linearity 0.01 NTU、0.1NTU、1NTU;0.1 Nephelos、1 Nephelos;0.01EBC、0.1EBC、1EBC
        Measurement Accuracy - turbidity linearity Readings +/- 5% (> 1000 NTU; 6700 Nephelos; 245 EBC) (@25 ℃/77 ° F)
        range conversion Automatic range conversion
        Turbidity Repeatability +/- 1% of the reading or 0.02 NTU (0.15 Nephelos; 0.1 EBC), whichever is greater
        minimum detection limit <0.02 NTU(0.15 Nephelos;0.01 EBC)
        Method/standard Turbidity (90 °) or scattering turbidity (90 ° & 180 °), conforming to USEPA Method 180.1 and Standard 2130B
        Turbidity measurement mode Ordinary measurement, continuous measurement, average measurement
        Turbidity calibrated mode 2, 3, 4, 5 point Manual calibration, built-in 5 point standard calibrating point: < 0.1NTU, 15NTU, 100NTU, 750NTU, 2000NTU
        Measurement range -Cl2 0.00 to 5.00mg/L Cl2
        Resolution -Cl2 0.01mg/L(≤3.5mg/L);0.10 mg/L(>3.50mg/L)
        Measurement Accuracy -Cl2 Reading +/- 0.02mg/L@25 ℃
        Measuring method -Cl2 Refer to USEPA method 330.5 or Standard Method 4500-Cl G, DPD method
        Calibration Mode-Cl2 Manual calibration (residual chlorine 1.0mg/L, total rate 1.0mg/L)
        Measurement Reagent-Cl2 HI93701-01/03 residual chlorine reagent; HI93711-01/03 total chlorine reagent (optional)
        Detector/Data Management Silicon Photocell, photovoltaic cell, narrow band interference filter, wavelength: 525nm; USB Interface, 200 sets of measurement Data storage
        Power-off mode 230V/50Hz, 20W; 15 minutes without any operation, it will automatically shut down
        Miscellaneous indicators 0 ℃ to 50 ℃; max 95% RH non-condensing; host size: 230x200x145mm, host Weight: 2.5Kg

        HANNA HI83414 Turbidity Meter Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Which instrument is recommended for simultaneous measurement of turbidity, residual chlorine and total chlorine in the drinking water industry?
        [A]
        This instrument combines the measurement of turbidity, residual chlorine, and total chlorine. It is a multi-functional machine specially designed for the drinking water industry. It has an automatic range conversion function, and the low turbidity range (0.00-40 NTU) and high turbidity range (0.00-4000 NTU) can meet the measurement needs of different concentration samples, especially in the low value range. High accuracy.
        [Q]
        What are the options for USEPA compliant instruments that require measurement of multiple turbidity units (NTU, Nephelos, EBC)?
        [A]
        The HANNA HI83414-02 turbidity meter supports a variety of turbidity unit measurements, including NTU, Nephelos and EBC, with automatic range conversion function. It uses EPA-specific custom Light source, which fully complies with USEPA 180.1 standard and Standard Method 2130B standard method to ensure the authority and accuracy of measurement results. The instrument also provides three turbidity Measurement modes of ordinary measurement, continuous measurement and average measurement to meet different experimental needs.
        HANNA
        HANNA HI83414 Benchtop residual chlorine - total chlorine - turbidity Tester (EPA standard)