HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
Residual chlorine measurement range: 0.00 to 5.00mg/L (asCl2), resolution: 0.01mg/L, accuracy: +/- 0.03mg/L +/- 3% of reading, total chlorine measurement range 0.00 to 5.00mg/L (asCl2), built-in reaction Timer to ensure consistent results between sample measurements and users.
HANNA-
Bante70 portable intelligent multiparameter instrument STIP-scan pH ORP Ion concentration conductivity TDS salinity resistivity
$ 716.00 -
HANNA HI70038P TDS calibrated liquid 6.44 g/L (ppt) /20mL * 25 packs
$ 152.00 -
HANNA HI97779 Chlorine Dioxide [DPD Method] Portable Photometer
$ 540.00 -
LEICI CO-572 Chemical Oxygen Demand Tester
$ 1535.00 -
Bante900P-CN Portable multiparameter Water Quality Meter
$ 778.00
Introduction
The HI97711 Residual Chlorine/Free Chlorine/Total Chlorine Photometer complies with IP67 waterproof standards and uses an innovative optical system design to provide excellent accuracy, repeatability and time required to make measurements. Hana's carefully designed CAL Check⢠function allows NIST traceable standards perform performance verification and calibration of the instrument, multiple measurement methods, users can choose to use powder reagents or water reagents, built-in reaction timer to ensure consistent results between sample measurements and users, automatically record 50 measurement readings, Good Laboratory Practice (GLP) displays date and time of last user calibration, battery status indicator light and auto-off setting.
Features
Compared with traditional tungsten lamps and other light sources, LED light sources have better performance and higher luminous efficiency. They can use less energy to provide stable light sources. LEDs can ignore the heat they generate because higher heat will affect the stability of electronic products. sex.
8 nm narrowband interference filter, accurate to ±1 nm, 25% higher absorbance, improved optical filter ensures higher Wavelength Accuracy and allows reception of brighter and stronger signals, higher measurement stability and Less wavelength error, ensuring measurement precision and accuracy.
The internal reference system compensates for any drift caused by battery Voltage fluctuations or ambient temperature changes by automatically adjusting the Voltage of the LED to achieve a consistent and stable light source output, allowing readings to quickly stabilize between blank (zero) measurements and sample measurements.
The high-quality concave focusing lens can collect all the light transmitted through the glass cuvette, reducing errors and readings caused by possible defects and scratches in the glass cuvette. offset.
CAL Check⢠feature, which allows performance verification and calibration of the instrument using NIST traceable standards; CAL Check⢠NIST curve calibration set, which is used to simulate specific absorbance values ââat each wavelength to verify the accuracy of subsequent readings. The CAL Check⢠screen guides the user step-by-step through the verification process and user calibration.
HANNA HI97711 PhotometerSpecifications
| LIST | VALUE |
|---|---|
| Residual chlorine Measurement Range | 0.00 to 5.00mg/L(asCl₂) |
| resolution | 0.01mg/L |
| Accuracy | +/- 0.03Mg/L +/- 3% of reading |
| Total chlorine Measurement Range | 0.00 to 5.00mg/L(asCl₂) |
| resolution | 0.01mg/L |
| Accuracy | +/- 0.03Mg/L +/- 3% of reading |
| Method standard | EPA 330.5 DPD |
| Light source | Light Emitting Diode @525nm, Silicon Light source, bandwidth 8nm, Wavelength Accuracy +/- 1.0nm |
| Reaction cup size | Diameter 24.6mm, inner diameter 22mm |
| GLP | Date, last calibrated date |
| Display | 128X64 pixel black and white LCD with backlight |
| automatic storage | 50 reading data |
| Battery life | 1.5VAA battery (3), greater than 800 hours (without backlight) |
| Automatic shutdown | Automatic shutdown after 15 minutes without operation |
| Applicable environment | 0 to 50℃;RH-max100% IP67 |
| Size/Weight | 142.5x102.5x50.5mm,380g |
HANNA HI97711 Photometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- HANNA HI96821 Digital refractometer operation guide
- Optical inspection structure for color readers: D/8 D/0 45 °/0
- Flame photometer and ionometer


HI97711



![HANNA HI97779 Chlorine Dioxide [DPD Method] Portable Photometer](http://img.nbchao.com/imgs/200/2024/03/28/1717070953986574.jpg)