      Home> STIP-scan> HANNA> HANNA HI97711 Photometer

      HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer

      Residual chlorine measurement range: 0.00 to 5.00mg/L (asCl2), resolution: 0.01mg/L, accuracy: +/- 0.03mg/L +/- 3% of reading, total chlorine measurement range 0.00 to 5.00mg/L (asCl2), built-in reaction Timer to ensure consistent results between sample measurements and users.

      Brand
      SKU: NB045266
      Italy HANNA
      Model
      Stock
      Loading…
      Price
      $ 540.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI97711 PhotometerOverview

        • Specifications
        • Comments
        • FAQs
        HI97711
        Photometer
        • HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
        • HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer Figure 1
        • HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer Figure 2
        Residual chlorine measurement range: 0.00 to 5.00mg/L (asCl2), resolution: 0.01mg/L, accuracy: +/- 0.03mg/L +/- 3% of reading, total chlorine measurement range 0.00 to 5.00mg/L (asCl2), built-in reaction Timer to ensure consistent results between sample measurements and users.

        Introduction

        The HI97711 Residual Chlorine/Free Chlorine/Total Chlorine Photometer complies with IP67 waterproof standards and uses an innovative optical system design to provide excellent accuracy, repeatability and time required to make measurements. Hana's carefully designed CAL Check™ function allows NIST traceable standards perform performance verification and calibration of the instrument, multiple measurement methods, users can choose to use powder reagents or water reagents, built-in reaction timer to ensure consistent results between sample measurements and users, automatically record 50 measurement readings, Good Laboratory Practice (GLP) displays date and time of last user calibration, battery status indicator light and auto-off setting.

        Features

        • Compared with traditional tungsten lamps and other light sources, LED light sources have better performance and higher luminous efficiency. They can use less energy to provide stable light sources. LEDs can ignore the heat they generate because higher heat will affect the stability of electronic products. sex.

        • 8 nm narrowband interference filter, accurate to ±1 nm, 25% higher absorbance, improved optical filter ensures higher Wavelength Accuracy and allows reception of brighter and stronger signals, higher measurement stability and Less wavelength error, ensuring measurement precision and accuracy.

        • The internal reference system compensates for any drift caused by battery Voltage fluctuations or ambient temperature changes by automatically adjusting the Voltage of the LED to achieve a consistent and stable light source output, allowing readings to quickly stabilize between blank (zero) measurements and sample measurements.

        • The high-quality concave focusing lens can collect all the light transmitted through the glass cuvette, reducing errors and readings caused by possible defects and scratches in the glass cuvette. offset.

        • CAL Check™ feature, which allows performance verification and calibration of the instrument using NIST traceable standards; CAL Check™ NIST curve calibration set, which is used to simulate specific absorbance values ​​at each wavelength to verify the accuracy of subsequent readings. The CAL Check™ screen guides the user step-by-step through the verification process and user calibration.

        VS

        HANNA HI97711 PhotometerSpecifications

        LIST VALUE
        Residual chlorine Measurement Range 0.00 to 5.00mg/L(asCl₂)
        resolution 0.01mg/L
        Accuracy +/- 0.03Mg/L +/- 3% of reading
        Total chlorine Measurement Range 0.00 to 5.00mg/L(asCl₂)
        resolution 0.01mg/L
        Accuracy +/- 0.03Mg/L +/- 3% of reading
        Method standard EPA 330.5 DPD
        Light source Light Emitting Diode @525nm, Silicon Light source, bandwidth 8nm, Wavelength Accuracy +/- 1.0nm
        Reaction cup size Diameter 24.6mm, inner diameter 22mm
        GLP Date, last calibrated date
        Display 128X64 pixel black and white LCD with backlight
        automatic storage 50 reading data
        Battery life 1.5VAA battery (3), greater than 800 hours (without backlight)
        Automatic shutdown Automatic shutdown after 15 minutes without operation
        Applicable environment 0 to 50℃;RH-max100% IP67
        Size/Weight 142.5x102.5x50.5mm,380g

        HANNA HI97711 Photometer Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        HANNA
        HANNA HI97711 Portable waterproof residual chlorine/free chlorine/total chlorine photometer
        Service
        Focus on online sales of Lab Testing Instruments