HANNA HI2040 Plate dissolved oxygen - saturated Dissolved Oxygen Meter
Dissolved oxygen range of 0.00~45.00mg/L, with manual, manual continuous and time interval three Data storage mode, support automatic temperature compensation.
HANNA-
LEICI chloride ion electrode calibrating solution, suitable for chloride ion composite electrode
$ 106.00 -
COD standard solution 1500mg/L, 250mL suitable for COD-571, DGB-401
$ 105.00 -
TDS Standard 7447 ppm, 480 ml
$ 102.00 -
JINGQI COD-5C Practical COD Speed Tester
$ 1507.00 -
HANNA HI9829-11042 high-precision multiparameter Water Quality Analyzer pH/ORP/EC/DO/turbidity 4 meters probe 230V
$ 7104.00
Introduction
HANNA has newly launched the revolutionary HI2000 (edge) series of multi-parameter analyzers. The same flat-panel host can realize acidity, pH-mV conversion, conductivity, total solid solubility, salinity, dissolved oxygen, saturated dissolved oxygen, temperature ° by replacing electrodes. Quickly measure water quality indicators such as C/°F. HI2000 (edge) series multi-parameter measuring instrument is the HANNA brand's design capability and product integration, and will set a new standard for the HANNA brand.
Features
Dissolved oxygen range: 0.00 to 45.00mg/L (ppm)
Saturated dissolved oxygen range: 0.0 to 300%
Accuracy: ±1.5% of reading or 1 word, whichever is greater
Zero (0%) and air (100%) single or two point calibration
Three data storage modes: manual, manual continuous and time interval
ATC automatic temperature compensation, altitude compensation and salinity compensation
GLP records calibration date, time, calibration, altitude, salinity, etc.
Customized replaceable polarographic dissolved oxygen electrodes and dissolved oxygen membranes
HANNA HI2040 Plate dissolved oxygen - saturated Dissolved Oxygen MeterSpecifications
| LIST | VALUE |
|---|---|
| DO Measurement Range | Dissolved oxygen: 0.00 to 45.00 mg/L (ppm), saturated dissolved oxygen: 0.0 to 300.0% |
| DO resolution of dissolved oxygen | 0.01 mg/L (ppm) ;0.1% |
| Dissolved oxygen DO measurement Accuracy | Reading +/- 1.5% or 1 word, whichever is greater |
| DO calibration method | Single or two point calibrated, 0% (recommended H17040 zero standard solution) and 100% (air auto calibration) |
| DO temperature compensation | Automatic (ATC) temperature compensation, 0 to 50.0 ° C (32.0 to 122.0 ° F) |
| DO salinity compensation | Compensation range: 0to 40 g/L, resolution: 1g/L |
| Dissolved oxygen DO highly compensated | Compensation range: -500 to 4000 meters, resolution: 100 meters |
| data storage | Up to 1000 sets (basic mode: 400 sets) of data storage, 200 sets of data storage manually clicked, |
| Electrode configuration | H1764080 Built-in temperature transducer Polarographic dissolved Oxygen electrode, 3.5mm Connector, 1m wire length |
| Temperature Measurement Range | -20.0 to 120.0℃ ( -4.0 to 248.0℉ ) |
| Temperature Resolution and Accuracy | Resolution: 0.1 ° C, 0.1 ° F; Accuracy : +/- 0.5 ℃, +/- 0.9 ° F |
| Data Interface | Standard USB interface, suitable for fast storage flash drive, Micro USB interface, suitable for data cable transmission and charging |
| Operating Environment | 0 to 50 ° C (32 to 122 ° F), Max95% RH, non-condensing |
| Power mode | 230AC/5VDC power adapter |
| Dimensions | 202x140x12mm |
| Weight | 250g |
HANNA HI2040 Plate dissolved oxygen - saturated Dissolved Oxygen Meter Packing list
machine X1, manual X1, certificate X1, warranty card X1