HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable photometer
Measurement range of chlorine dioxide 0.00 to 2.00 mg/L (as ClO2), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.01 mg/L +/- 5% of reading, commonly used in drinking water treatment, swimming pool disinfection, industrial production and other fields.
HANNA-
E-ORPSCAN-S ORP electrode
$ 111.00 -
DDKSIC PC100T Desktop pH, Conductivity Meter (touch screen type) pH/mV (ORP electrode optional)/conductivity/resistivity/TDS/salinity/℃
$ 1275.00 -
YUEFENG SZ8116 iron analyzer, iron content analyzer 0~ 0.8mg/L
$ 343.00 -
HANNA HI5222 Professional desktop acidity pH/mV-ISE-temperature Tester
$ 1743.00 -
Bante904-UK Precision pH/conductivity /TDS/salinity/resistivity meter
$ 643.00
Introduction
HI97738 Chlorine Dioxide [Chlorophenol Red Method] Portable Photometer is an instrument used to measure the content of chlorine dioxide (ClO2) in water. Chlorine dioxide is a strong oxidant commonly used in water treatment and disinfection processes. It can effectively kill bacteria, viruses and other microorganisms in water, and can remove odor and color. It is often used in drinking water treatment, swimming pool disinfection, industrial production and other fields to ensure that water quality reaches safety standards and meets the requirements of relevant regulations.
HI97738 Chlorine Dioxide [Chlorophenol Red Method] Portable Photometer complies with IP67 waterproof standards, adopts innovative optical system design, has good accuracy, repeatability and time required to make measurements, CAL CheckTM function allows the use of NIST traceable standards Performance verification and calibration of the instrument, multiple measurement methods, built-in reaction timer to ensure consistent results between sample measurements and users, Good Laboratory Practice (GLP) display of the date and time of the last user calibration, battery status indicator light and automatic shutdown settings.
Features
LED high-quality light source system has good performance and high luminous efficiency;
High-quality optical filters, high measurement stability and less wavelength error ensure measurement precision and accuracy;
Unique reference Detector enables fast and stable readings between blank (zero) measurement and sample measurement;
Stable light source settings reduce errors and reading offsets caused by defects in glass cuvettes;
CAL CheckTM function.
HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable PhotometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range of chlorine dioxide | 0.00 to 2.00 mg/L (as ClO2) |
| resolution | 0.01 mg/L |
| Accuracy @25 ℃ | +/- 0.01 mg/L +/- 5% of reading |
| Method standard | chlorophenol red method |
| Light source | LED@575nm, Silicon Light source, Bandwidth 8nm, Wavelength Accuracy +/- 1.0nm |
| Reaction cup size | Diameter 24.6mm, inner diameter 22mm |
| GLP | Date, last calibrated date |
| Display | 128X64 pixel black and white LCD with backlight |
| automatic storage | The last 50 measurements |
| Battery life | 1.5V AA battery (3), greater than 800 hours (without backlight) |
| Automatic shutdown | Automatic shutdown after 15 minutes without operation |
| Applicable environment | 0 to 50℃;RH-max100% IP67 |
| Size/Weight | 142.5 x 102.5 x 50.5 mm,380g |
HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable Photometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
![HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable Photometer](http://img.nbchao.com/imgs/800/2024/03/29/1425040730396827.jpg)
![HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable photometer](http://img.nbchao.com/imgs/60/2024/03/29/1425040730396827.jpg)
HI97738






![HANNA HI97738 Chlorine dioxide [chlorophenol red method] Portable photometer](http://img.nbchao.com/imgs/100/2024/03/29/1425040730396827.jpg)