HANNA HI97769 Surfactant [SDBS] Portable Photometer
Measurement range 0.00 to 3.50 mg/L (as SDBS), resolution 0.01 mg/L, accuracy @25 ℃: +/- 0.04 mg/L +/- 3% of reading, widely used in water treatment, environment monitoring, detergent production and detergent residue detection.
HANNA-
JINGQI WD8101 Sulfate Tester
$ 481.00 -
HANNA HI98192 Conductivity Meter EC/TDS/Electrical resistivity /NaCl/Temperature professional measurement
$ 1223.00 -
JINGQI WD8105 Cyanide Tester
$ 481.00 -
DDKSIC ORP301 composite ORP electrode for waste water, swimming pool water measurement
$ 122.00 -
DDKSIC PCD100 desktop multiparameter analyzer (push button)
$ 943.00
Introduction
HI97769 Surfactant [SDBS] Portable Photometer is an instrument used to measure the surfactant content in water. Surfactants are compounds that reduce the surface tension of liquids and promote the dispersion or emulsification of liquids. They are widely used in detergents, detergents, emulsifiers and other products. Measuring surfactant content in water is important for assessing water quality, monitoring pollution, and detecting detergent residues. It is widely used in fields such as water treatment, environmental monitoring, detergent production and detergent residue detection to ensure water quality safety, product quality and environmental protection.
HI97769 Surfactant [SDBS] Portable Photometer complies with IP67 waterproof standards, adopts innovative optical system design, has good accuracy, repeatability and time required to make measurements, CAL CheckTM function allows the instrument to be tested using NIST traceable standards Performance verification and calibration, multiple measurement methods, built-in reaction timer to ensure consistent results between sample measurements and users, Good Laboratory Practice (GLP) display of date and time of last user calibration, battery status indicator light and automatic shutdown set up.
Features
LED high-quality light source system has good performance and high luminous efficiency;
High-quality optical filters, high measurement stability and less wavelength error ensure measurement precision and accuracy;
Unique reference Detector enables fast and stable readings between blank (zero) measurement and sample measurement;
Stable light source settings reduce errors and reading offsets caused by defects in glass cuvettes;
CAL CheckTM function.
HANNA HI97769 Surfactant [SDBS] Portable PhotometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range of anion surfactants | 0.00 to 3.50 mg/L (as SDBS) |
| resolution | 0.01 mg/L |
| Accuracy @25 ℃ | +/- 0.04 mg/L +/- 3% of the reading; |
| Method standard | EPA Method 425.1 and modifications to the Standard Method for Water and Wastewater Inspection (20th Edition, 5540C) |
| Light source | LED@610nm, Silicon Light source, Bandwidth 8nm, Wavelength Accuracy +/- 1.0nm |
| Reaction cup size | Diameter 24.6mm, inner diameter 22mm |
| GLP | Date, last calibrated date |
| Display | 128X64 pixel black and white LCD with backlight |
| automatic storage | The last 50 measurements |
| Battery life | 1.5V AA battery (3), greater than 800 hours (without backlight) |
| Automatic shutdown | Automatic shutdown after 15 minutes without operation |
| Applicable environment | 0 to 50℃;RH-max100% IP67 |
| Size/Weight | 142.5 x 102.5 x 50.5 mm,380g |
HANNA HI97769 Surfactant [SDBS] Portable Photometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
![HANNA HI97769 Surfactant [SDBS] Portable Photometer](http://img.nbchao.com/imgs/800/2024/03/28/1732050743917728.jpg)
![HANNA HI97769 Surfactant [SDBS] Portable Photometer](http://img.nbchao.com/imgs/60/2024/03/28/1732050743917728.jpg)
HI97769






![HANNA HI97769 Surfactant [SDBS] Portable Photometer](http://img.nbchao.com/imgs/100/2024/03/28/1732050743917728.jpg)