HANNA HI97779 Chlorine Dioxide [DPD Method] Portable Photometer
Measurement range 0.00 to 2.00 mg/L (as ClO2), resolution 0.01 mg/L, accuracy @25 ℃ reading +/- 0.10 mg/L +/- 5%, high quality Optical inspection filter, High measurement Stability and less wavelength error ensure Measurement accuracy and accuracy.
HANNA-
TONGAO TR-140H Portable Sulfide Tester 0-4mg/L
$ 786.00 -
HANNA HI98198 Portable (Fluorescence Method) Dissolved Oxygen DO-Saturated Dissolved Oxygen Meter
$ 2850.00 -
Bante902-UK Precision pH/conductivity /TDS/salinity/resistivity meter
$ 607.00 -
DDKSIC PD10 portable pH, Dissolved Oxygen Meter (color screen) pH/mV (ORP electrode optional)/DO/℃
$ 717.00 -
LEICI Ammonia Gas sensing electrode calibrated solution for Ammonia Gas sensing electrode
$ 106.00
Introduction
HI97779 Chlorine Dioxide [DPD Method] Portable Photometer is an instrument used to measure the content of chlorine dioxide (ClO2) in water. Chlorine dioxide is a strong oxidant commonly used in water treatment and disinfection processes. It can effectively kill bacteria, viruses and other microorganisms in water, and can remove odor and color. It is widely used in drinking water treatment, swimming pool disinfection, industrial production and other fields to ensure that water quality reaches safety standards and meets the requirements of relevant regulations.
HI97779 Chlorine Dioxide [DPD Method] Portable Photometer complies with IP67 waterproof standards, adopts innovative optical system design, has good accuracy, repeatability and time required to make measurements, CAL CheckTM function allows the use of NIST traceable standards to verify the instrument Perform performance verification and calibration, multiple measurement methods, built-in reaction timer to ensure consistent results between sample measurements and users, Good Laboratory Practice (GLP) display of date and time of last user calibration, battery status indicator light and automatic Shutdown settings.
Features
LED high-quality light source system with good performance and high luminous efficiency
High-quality optical filters, high measurement stability and less wavelength error ensure measurement precision and accuracy
Unique reference Detector enables fast and stable readings between blank (zero) measurements and sample measurements
Stable light source settings reduce errors and reading shifts caused by defects in glass cuvettes
CAL CheckTM function
HANNA HI97779 Chlorine dioxide [DPD method] Portable PhotometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range of chlorine dioxide | 0.00 to 2.00 mg/L (as ClO2) |
| resolution | 0.01 mg/L |
| Accuracy @25 ℃ | +/- 0.10 mg/L +/- 5% of reading |
| Method standard | 4500 ClO2 D |
| Light source | LED@525nm, Silicon Light source, Bandwidth 8nm, Wavelength Accuracy +/- 1.0nm |
| Reaction cup size | Diameter 24.6mm, inner diameter 22mm |
| GLP | Date, last calibrated date |
| Display | 128X64 pixel black and white LCD with backlight |
| automatic storage | The last 50 measurements |
| Battery life | 1.5V AA battery (3), greater than 800 hours (without backlight) |
| Automatic shutdown | Automatic shutdown after 15 minutes without operation |
| Applicable environment | 0 to 50℃;RH-max100% IP67 |
| Size/Weight | 142.5 x 102.5 x 50.5 mm,380g |
HANNA HI97779 Chlorine dioxide [DPD method] Portable Photometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
![HANNA HI97779 Chlorine dioxide [DPD method] Portable Photometer](http://img.nbchao.com/imgs/800/2024/03/28/1717070953986574.jpg)
![HANNA HI97779 Chlorine Dioxide [DPD Method] Portable Photometer](http://img.nbchao.com/imgs/60/2024/03/28/1717070953986574.jpg)
HI97779






![HANNA HI97779 Chlorine Dioxide [DPD Method] Portable Photometer](http://img.nbchao.com/imgs/100/2024/03/28/1717070953986574.jpg)