HANNA HI717 phosphoric acid HR Tintometer
Measurement range 0.0 to 30.0 ppm, resolution 0.1 ppm, accuracy +/- 1.0 ppm +/- 5% of the reading, widely used in water quality monitoring, wastewater treatment, environment monitoring, agriculture and scientific research laboratories to assess and monitor phosphoric acid content in water bodies.
HANNA-
Chloride standard solution 1000ppm, 480ml
$ 130.00 -
HANNA HI711 total chlorine Tintometer
$ 192.00 -
LEICI 6801-01 (zero potential 2) sodium ion electrode adaptable to DWS-51 digital display BNC (Q25 type)
$ 117.00 -
Ammonium ion strength regulator 1000ppm 480ml
$ 130.00 -
HANNA HI709 HR Tintometer
$ 192.00
Introduction
HI717 Phosphate HR Colorimeter is an instrument used to measure the concentration of phosphate in water samples, where "HR" usually means "High Sensitivity" (High Range). This Colorimeter is often used to measure higher concentrations of phosphate in water, for example in wastewater treatment, environmental monitoring or agriculture.
The working principle of the phosphate HR Colorimeter is based on the chemical reaction between phosphate and specific reagents, producing a color change. Common measurement methods include using acidic solutions and reducing agents to convert phosphate into colorless phosphate under acidic conditions, and then adding a reagent containing an indicator to form a colored product. Determine the concentration of phosphate by measuring the absorbance of the solution or comparing the depth of color.
HI717 Phosphate HR Colorimeter is widely used in water quality monitoring, wastewater treatment, environmental monitoring, agricultural fields and scientific research laboratories to evaluate and monitor phosphate content in water bodies.
HANNA HI717 Phosphoric acid HR TintometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0.0 to 30.0 ppm |
| resolution | 0.1 ppm |
| Accuracy | +/- 1.0 ppm +/- 5% of the reading |
| Light source | LED @525nm |
| Automatic shutdown | No operation after ten minutes |
| Measuring method | Refer to the standard detection method for water and wastewater, 18th edition amino acid method |
| optional reagents | HI717-25 |
| calibration group | HI717-11 |
HANNA HI717 Phosphoric acid HR Tintometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI717