      Home> Ion Meter> HANNA> HANNA HI761 Total chlorine ULR Tintometer

      HANNA HI761 total chlorine ULR Tintometer

      Measurement range 0 to 500 ppb, LED Light source has better performance and higher luminous efficiency, commonly used in the detection of ultra-low concentration total chlorine content in water instrument.

      Brand
      SKU: NB045616
      Italy HANNA
      Model
      Stock
      Loading…
      Price
      $ 192.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI761 Total chlorine ULR TintometerOverview

        • Specifications
        • Comments
        • FAQs
        HI761
        Total chlorine ULR Tintometer
        • HANNA HI761 total chlorine ULR Tintometer
        • HANNA HI761 total chlorine ULR Tintometer Figure 1
        • HANNA HI761 total chlorine ULR Tintometer Figure 2
        Measurement range 0 to 500 ppb, LED Light source has better performance and higher luminous efficiency, commonly used in the detection of ultra-low concentration total chlorine content in water instrument.

        Introduction

        Chlorine is a commonly used water disinfectant. However, excessive chlorine in water can form toxic and harmful substances, so monitoring of chlorine content in swimming pool and hot spring water, fruit and vegetable cleaning water, and drinking water is crucial. The total chlorine ULR Colorimeter is an instrument used to detect ultra-low concentration total chlorine content in water. ULR stands for "Ultra Low Range" and refers to the fact that it can detect very low chlorine concentrations, usually at micrograms/liter or lower levels.

        Features

        Compared with traditional tungsten lamps and other light sources, LED light sources have better performance and higher luminous efficiency. They can use less energy to provide a stable light source. LEDs can ignore the heat they generate because higher heat will affect electronic products. stability.

        HANNA's carefully designed CAL CheckTM function allows performance verification and calibration of the instrument using NIST traceable standards; CAL CheckTM NIST curve calibration set is used to simulate specific absorbance values ​​at each wavelength to verify the accuracy of subsequent readings.

        Application scope

        • Used to monitor chlorine concentrations in drinking water to ensure compliance with relevant water quality standards and regulations. Total chlorine concentration is an important parameter in drinking water and has a critical impact on water quality and safety.

        • In the swimming pool water treatment process, the control of total chlorine concentration is very important to ensure water quality hygiene and the health and safety of swimmers. The Total Chlorine ULR Colorimeter can help monitor the chlorine concentration in swimming pool water to ensure it is within a safe range.

        • In the field of environmental monitoring, the total chlorine ULR Colorimeter can be used to detect the chlorine content in surface water, groundwater, and industrial discharges to assess its impact and harm to the environment.

        • In some industrial processes, it may be necessary to monitor and control the chlorine content in water to ensure the smooth progress of the production process and the stability of product quality.


        VS

        HANNA HI761 Total chlorine ULR TintometerSpecifications

        LIST VALUE
        Measurement range 0 to 500 ppb
        resolution 1 ppb
        Accuracy +/- 5 ppb +/- 5% of the reading
        Light source LED @525nm
        Automatic shutdown No operation after ten minutes
        Measuring method Refer to USEPA method 330.5, DPD method Refer to water and wastewater standard detection method 20th edition, 4500-CI method
        basic configuration Host, HI761-25 reagent, HI731313H Glass Colorimetric dish, English instruction manual and exquisite Chinese color comprehensive operation manual, HI721025 carrying case
        optional reagents HI761-25
        calibration group HI761-11

        HANNA HI761 Total chlorine ULR Tintometer Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        What instrument is good for measuring the ultra-low concentration of total chlorine in drinking water?
        [A]
        HI761 photometer is designed to measure 0-500 ppb ultra-low range total chlorine, in line with drinking water standards, with LED Light source Stability, simple operation and calibrated inspection function.
        [Q]
        Swimming pool water quality monitoring needs to measure total chlorine, which instrument is suitable?
        [A]
        Select the HI761 total chlorine ULR Tintometer, which uses the DPD method to measure ultra-low concentration of chlorine, which can ensure that the chlorine content of swimming pool water is within a safe range, prevent excessive chlorine from endangering health, and the portable design is convenient for on-site testing.
        +HANNA HI761 Total chlorine ULR Tintometer Big data
          +HANNA HI761 Total chlorine ULR TintometerKnowledge
          +HANNA HI761 Total chlorine ULR TintometerStandard
          +Navigation
          HANNA
          HANNA HI761 total chlorine ULR Tintometer
          Service
          Focus on online sales of Lab Testing Instruments