HANNA HI767 Nitrite LR Tintometer (for seawater)
Measurement range 0 to 999 ppb, resolution 1 ppb, accuracy +/- 10 ppb +/- 4% of the reading, is a rapid and accurate measurement of nitrite content in water samples, widely used in environmental protection, drinking water safety and other fields.
HANNA-
LEICI PNH3 -3 Ammonia Gas sensing electrode Adapted to DWS-296 Ammonia Nitrogen Analyzer BNC (Q24 type)
$ 486.00 -
Bante931-I Laboratory Ion Meter Ion concentration Detector
$ 671.00 -
HANNA HI708 Nitrite HR Tintometer
$ 190.00 -
LEICI PCU-1-01 copper ion electrode for pH, Ion Meter BNC (Q19 type)
$ 120.00 -
LEICI 972102 chloride ion composite electrode
$ 263.00
Introduction
Nitrite is a nitrogen-containing compound that usually exists in the ionic form of NO2-. In water samples, nitrites may come from water contamination, especially contamination caused by chemicals or biological activity. Because nitrite is potentially harmful to human health, monitoring its concentration is very important for quality control of drinking water and environmental water.
HI767 Nitrite LR Colorimeter is an experimental instrument used to detect the nitrite content in water samples. The HI767 Nitrite LR Colorimeter is based on the chemical reaction that occurs between nitrite and reagents. The concentration of nitrite in a water sample is determined by measuring the optical properties of this chromogenic compound, such as absorbance or color intensity.
HI767 Nitrite LR Colorimeter is an experimental instrument used to quickly and accurately measure the nitrite content in water samples. It is widely used in environmental protection, drinking water safety and other fields.
Features
Compared with traditional tungsten lamps and other light sources, LED light sources have better performance and higher luminous efficiency. They can use less energy to provide a stable light source. LEDs can ignore the heat they generate because higher heat will affect electronic products. stability.
HANNA's carefully designed CAL CheckTM function allows performance verification and calibration of the instrument using NIST traceable standards; CAL CheckTM NIST curve calibration set is used to simulate specific absorbance values ââat each wavelength to verify the accuracy of subsequent readings.
HANNA HI767 Nitrite LR Tintometer (Seawater Sample)Specifications
| LIST | VALUE |
|---|---|
| Measurement range | 0 to 999 ppb |
| resolution | 1 ppb |
| Accuracy | +/- 10 ppb +/- 4% of the reading |
| Light source | LED @525nm |
| Automatic shutdown | No operation after two minutes |
| Measuring method | EPA 354.1 Diazo method ferrous sulfate method |
| optional reagents | HI767-25 |
| calibration group | HI767-11 |
HANNA HI767 Nitrite LR Tintometer (Seawater Sample) Packing list
machine X1, manual X1, certificate X1, warranty card X1