HANNA HI770 Silica LR Tintometer
Measurement range 0 to 200 ppm, resolution 1 ppm, accuracy +/- 2 ppm +/- 5% of the reading, widely used in various laboratories, water treatment plants, environment monitoring stations and other occasions.
HANNA-
Qiwei PXS-Ca Calcium Ion Concentration Meter
$ 368.00 -
BANTE S30-Cl Wireless Bluetooth Chloride Ion Meter 0.000005~ 1mol/L
$ 706.00 -
BANTE A131-Na laboratory Ion Meter sodium ion
$ 832.00 -
LEICI PCU-1-01 copper ion electrode for pH, Ion Meter BNC (Q19 type)
$ 120.00 -
Potassium ion strength regulator 1000ppm 480ml
$ 130.00
Introduction
Silicon is an abundant element in the earth's crust, accounting for 28% of the total. Water and water vapor have very little solubility in silicon, so water and water vapor quickly form a surface protective layer of silicon dioxide. Silicon combines with other elements to form various types of silica and silica. The concentration of soluble silica molecules is critical to the aquaculture industry as it affects (and limits) diatom growth.
The HI770 Silica LR Colorimeter determines the concentration of silica in a water sample by measuring the intensity of the color produced by silica and reagents.
HI770 Silica LR Colorimeter is widely used in various laboratories, water treatment plants, environmental monitoring stations and other occasions to monitor the silica content in water quality and ensure that the water quality meets relevant standards and requirements. The silica LR Colorimeter can quickly and accurately measure the content of low-concentration silica in water samples, providing important data support for related industries.
Features
Compared with traditional tungsten lamps and other light sources, LED light sources have better performance and higher luminous efficiency. They can use less energy to provide a stable light source. LEDs can ignore the heat they generate because higher heat will affect electronic products. stability.
HANNA's carefully designed CAL CheckTM function allows performance verification and calibration of the instrument using NIST traceable standards; CAL CheckTM NIST curve calibration set is used to simulate specific absorbance values ââat each wavelength to verify the accuracy of subsequent readings.
HANNA HI770 Silica LR TintometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0 to 200 ppm |
| resolution | 1 ppm |
| Accuracy | +/- 2 ppm +/- 5% of the reading |
| Light source | LED @470nm |
| Automatic shutdown | No operation after ten minutes |
| Measuring method | Refer to USEPA method 370.1 4500-SiO2, C method |
| optional reagents | HI770-25 |
| calibration group | HI770-11 |
HANNA HI770 Silica LR Tintometer Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI770