      HANNA HI93542 Dual Channel Dual Range, Wide Range Temperature Meter

      Measurement range -200.0 to 999.9 ℃, suitable for K type, J type, T type different types of temperature sensors, HOLD lock key function, lock measurement data, easy to record and view.

      Brand
      SKU: NB045653
      Italy HANNA
      Model
      Stock
      Loading…
      Price
      $ 515.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI93542 Temperature measuring instrumentOverview

        • Specifications
        • Comments
        • FAQs
        HI93542
        Temperature measuring instrument
        • HANNA HI93542 Dual Channel Dual Range, Wide Range Temperature Meter
        Measurement range -200.0 to 999.9 ℃, suitable for K type, J type, T type different types of temperature sensors, HOLD lock key function, lock measurement data, easy to record and view.

        Introduction

        HI93542 dual-channel dual-range wide-range temperature measuring instrument adopts low-Voltage error-proofing system BEPS and battery power display design to avoid erroneous readings and remind you to replace the battery in time. The two-line display screen can display the current temperature measurement value and the size record value at the same time. The 'HOLD' key can lock the screen display value for easy data viewing and recording. The dedicated KJT key allows users to adjust the temperature measurement value according to the needs of different measurement ranges and measurement environments. Replace different temperature probes for K-type, T-type, and J-type temperature measurements.

        Features

        • Waterproof design, large-screen double-line LCD display, showing numerical values.

        • It is suitable for different types of temperature probes such as K-type, J-type and T-type, and has a wide range of applications.

        • Low battery error-proofing system, battery display icon to remind you to replace the battery in time.

        • HOLD lock key function to lock measurement data for easy recording and viewing.

        • The ℃/℉ key can easily and quickly switch between Celsius and Fahrenheit temperatures.

        VS

        HANNA HI93542 Temperature measuring instrumentSpecifications

        LIST VALUE
        K-resolution 0.1 ℃ (-149.9 to 999.9 ℃), 0.2 ℃ (-200.0 to -150.0 ℃), 1 ℃ (all ranges) 0.1 ° F (-24.9 to 999.9 ° F), 0.2 ° F (-249.9 to -25.0 ° F) 0.3 ° F (-328.0 to -250.0 ° F), 1 ° F (all ranges)
        J type temperature sensor Measurement range -200.0 to 999.9℃、-328.0 to 999.9℉、1000 to 1832 ℉
        J-resolution 0.1℃(-200.0 to 999.9℃)、0.1℉(-24.9 to 999.9℉)0.2℉(-249.9 to -250℉)、0.3℉(-328.0 to -150.0℉)、1 ℉(1000 to 1832℉)
        Measurement range of T type temperature sensor -200.0 to 400.0℃、-328.0 to 752.0℉
        T-resolution 0.1℃(-149.9 to 4000℃)、0.2℃(-200.0 to -150.0℃)0.1℉(0.0 to 752.0℉)、0.2℉(-270.0 to -0.1℉)0.3℉(-328.0 to -270.0)
        Measurement Accuracy (ignoring temperature sensor error) +/- 0.5 ℃ (-100.0 to 999.9 ℃)、 +/- 1 ℃ (all ranges) +/- 1 ° F (-148.0 to 999.9 ℉)、 +/- 1.5 ° F (all ranges)
        Measurement channel Double side interface, can be connected to two temperature sensors at the same time
        Probe type HI766 Series K Thermocouple temperature sensor
        CAL key N/A
        Backlit LCD N/A
        RS232 N/A
        Power mode 1.5V AA x3 battery
        Automatic shutdown Select to turn off the automatic shutdown mode and set the automatic shutdown for 8 minutes or 60 minutes
        Operating Environment -10 to 50℃ (14 to 122 ℉),RH max 100%
        Size Weight Host size: 150x80x36mm, host Weight: 235g
        basic configuration Host, Chinese and English instruction manual

        HANNA HI93542 Temperature measuring instrument Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Is the price listed on the website the final cost for overseas purchases?
        [A]
        No, it isn't. This is the ex-factory price of the product in the Chinese Mainland. In addition to this price, buyers from different countries need to account for additional costs such as shipping fees, tariffs, and others. For specific regional quotes, please consult our customer service or fill out a quotation form.
        [Q]
        What is the specific process for purchasing the product?
        [A]
        First, please click on the quotation form on the website and fill in detailed information. Our customer service personnel will then send you a quotation based on your specific country and region, confirming payment and delivery methods. Following this, we proceed with contract signing, payment, and shipment. You can then await delivery.
        [Q]
        What should I do if the instrument I purchase needs repair?
        [A]
        After-sales repair for overseas instruments is an unavoidable issue. Our repair terms stipulate that the sender is responsible for the shipping and insurance costs incurred for the repair. Repairs within the warranty period are free, while repair costs beyond the warranty period are determined based on the actual situation.
        +HANNA HI93542 Temperature measuring instrument Big data
          +HANNA HI93542 Temperature measuring instrumentSimilar products
          +HANNA HI93542 Temperature measuring instrumentKnowledge
          +Navigation
          HANNA
          HANNA HI93542 Dual Channel Dual Range, Wide Range Temperature Meter
          Service
          Focus on online sales of Lab Testing Instruments