      (G/100g) Measurement range 0 to 28, (g/100mL) Measurement range 0 to 34, specific gravity (S.G.) Measurement range 1.000 to 1.216, can display 4 different reference units, stainless steel sample chamber, easy to clean and anti-corrosion.

      Brand
      SKU: NB045673
      Italy HANNA
      Model
      Stock
      Loading…
      Price
      $ 486.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HANNA HI96821 Sodium chloride refractive analyzerOverview

        • Specifications
        • Comments
        • FAQs
        HI96821
        Sodium chloride refractive analyzer
        • HANNA HI96821 sodium chloride refractive analyzer (fresh water sample)
        • HANNA HI96821 sodium chloride refractive analyzer (fresh water sample) Figure 1
        • HANNA HI96821 sodium chloride refractive analyzer (fresh water sample) Figure 2
        (G/100g) Measurement range 0 to 28, (g/100mL) Measurement range 0 to 34, specific gravity (S.G.) Measurement range 1.000 to 1.216, can display 4 different reference units, stainless steel sample chamber, easy to clean and anti-corrosion.

        Introduction

        HI96821 refractometer measures the refractive index of a liquid solution sample and converts it into the sodium chloride content of the sample. It is specially used for the food industry and is not suitable for seawater salinity measurement.

        The refractive index measurement is very simple and fast. The user only needs to calibrate the refractometer with distilled or deionized water and then add two drops of the sample to be measured into the sample chamber. The sodium chloride measurement value of the sample to be measured can be obtained within a few seconds. . The instrument automatically performs temperature compensation, and the measurement results are accurate and reliable. Samples are measured after simple user calibration using deionized or distilled water. The instrument measures the refractive index of the solution within seconds, performs the necessary calculations, and displays the results in selected units. Digital refractometers eliminate the uncertainties associated with mechanical refractometers, allowing portable measurements where needed.

        The instrument adopts internationally recognized reference unit conversion and temperature compensation methods and can display NaCI concentration in 4 different reference units: g/100g, g/100 mL, specific gravity and °Baumé (degrees of Baume). The second line of the LCD screen can simultaneously display the measured temperature, low battery prompt icon and other help information.

        Characteristics

        • Two-line LCD display with temperature reading below the measured value.

        • ATC, automatic temperature compensation.

        • BEPS, low battery reminder, ensures accurate and effective readings.

        • IP65 waterproof, suitable for laboratory and field measurements.

        • Fast and accurate measurement, measurement results are quickly displayed in 1.5 seconds.

        • One-point calibration, use distilled or deionized water.

        • For micro-volume samples, only 2 drops of sample are needed.

        • Automatically shuts down if not used for three minutes.

        • Stainless steel sample chamber, easy to clean and anti-corrosion.

        • Easy to operate, just drop the sample and press the button to read, simple and fast.

        • ABS heat shrink plastic carrying case.

        VS

        HANNA HI96821 Sodium chloride refractive analyzerSpecifications

        LIST VALUE
        Measurement range - (g/100g) 0 to 28
        Resolution - (g/100g) 0.1
        Accuracy(@25 C/77° F)-(g/100g) ±0.2
        Measurement range - (g/100mL) 0 to 34
        Resolution - (g/100mL) 0.1
        Accuracy(@25 C/77° F)-(g/100mL) ±0.2
        Measurement range - specific gravity (S.G.) 1.000 to 1.216
        Resolution - specific gravity (S.G.) 0.001
        Accuracy (@25 C/77 ° F) - specific gravity (S.G.) ±0.002
        Measurement range - ° Baumé 0 to 26
        Resolution - ° Baumé 0.1
        Accuracy @25 C/77 ° F - ° Baumé ±0.2
        Measurement range 0 to 80 ℃(32 to 176 ℉)
        temperature resolution 0.1℃(0.1 ℉)
        Temperature Accuracy @25 C/77 ° F ±0.3℃(±0.5 ℉)
        Temperature compensation 10 ℃ to 40 ℃ automatic temperature compensation
        Measurement time Approximately 1.5 seconds
        Minimum sample Volume 100 μL (covering all prisms)
        Light source Yellow LED
        Sample room Stainless Steel Sample Chamber, Hard Glass Prism
        Automatic shutdown After 3 minutes of use
        Protection level IP65
        Power/Battery life 9V/about 5000 sets of readings
        basic configuration Host, battery and instruction manual

        HANNA HI96821 Sodium chloride refractive analyzer Packing list

        machine X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        How do I switch between Measurement units and Temperature units?
        [A]
        Concentration Unit switch: Press the RANGE key to cycle to switch G-G (g/100g), G-L (g/100mL), S. G (specific gravity), BAU (weight). Temperature Unit switch: Press and hold the ON/OFF key for 8 seconds to enter the setting mode. Keep pressing the ON/OFF key, and then press the ZERO key to switch ° C/° F.
        [Q]
        How do you know if the prism should be replaced?
        [A]
        It can be seen with the naked eye that there are scratches or fog, and the calibrating fails all the time. The same sample has been tested several times, and the results are much different. Generally, it takes two years or about 5,000 times to check.
        [Q]
        Can you test other liquids? Such as sugar water?
        [A]
        This machine is dedicated to measuring saline water concentration. Measurement of other liquids may: the number is inaccurate, the prism is broken, and then the measurement of saline water is also inaccurate. To measure other liquids, you have to buy Miscellaneous models.
        +HANNA HI96821 Sodium chloride refractive analyzer Big data
          +HANNA HI96821 Sodium chloride refractive analyzerKnowledge
          +HANNA HI96821 Sodium chloride refractive analyzerStandard
          +Navigation
          HANNA
          HANNA HI96821 sodium chloride refractive analyzer (fresh water sample)
          Service
          Focus on online sales of Lab Testing Instruments