HANNA HI88703 Desktop multi-range Turbidimeter (EPA standard)
Measurement range - turbidity nonlinear 0.0 to 99.9NTU, +/- 1% turbidity Repeatability readings, multi-range measurement, automatic range conversion, dedicated receiver cum Light source system, powerful CAL CHECK Calibration Adjustment.
HANNA-
YueFeng SGZ-100BJ Beer Turbidity Meter 0~100EBC
$ 568.00 -
JINGQI WGZ-400B Portable precision low turbidity instrument
$ 481.00 -
NOBOTECH ZS-600 submerged online Turbidimeter 0-10000NTU
$ 643.00 -
Qiwei WGZ-200AS Microcomputer Turbidity Meter 0~1000NTU
$ 187.00 -
HANNA HI88703 Desktop multi-range Turbidimeter (EPA standard)
$ 2958.00
Introduction
HI88703 is a high-precision multi-range laboratory Turbidity Meter that can perform linear and non-linear turbidity measurements and beer turbidity measurements. It is suitable for the water industry, beer industry, etc.; it has different measurement range options, and low turbidity range ( 0.00 to 40.00NTU) and high turbidity range (0.00 to 4000NTU), especially in the low value range, it has extremely high accuracy and precision, and is suitable for the measurement of samples with different concentrations in different fields. Complying with USEPA 180.1 and Standard Method 2130B, it has a powerful CAL CHECK calibration function and uses HI88703-11 turbidity calibration set (turbidity scale: â¤0.10, 15, 100, 750, 2000 NTU) to effectively calibrate the instrument. Perform verification and calibration to ensure the accuracy and reliability of the instrument.
High-precision analytical measurement
Turbidity refers to the scattering of light caused by tiny particles in water; the greater the turbidity, the greater the number of particles in the water; because even in very pure liquids, the liquid molecules will scatter light to a certain extent.
HI88703 uses an EPA-specific customized light source. The microprocessor calculates the turbidity value through the light intensity reaching the photoDetector; it effectively corrects color interference and has chromaticity compensation and automatic light source compensation functions to avoid interference caused by light source fluctuations. No need for frequent calibration. The lowest detection limit for turbidity is determined by the concentration of stray light; stray light is scattering not caused by suspended particles. The optical path design of HI88703 effectively reduces stray light, allowing the instrument to ensure excellent accuracy, precision, and reliability in low turbidity measurements.
Characteristics
Multi-range measurement, automatic range conversion.
Linear turbidity, nonlinear turbidity determination, beer turbidity determination.
USEPA standard and Standard Method 2130B method.
GLP management function, query settings, calibration, time and other information.
2, 3, 4, and 5-point manual calibration, built-in 5-point turbidity calibration points.
USB data interface, 200 sets of data storage, data management.
HANNA HI88703 Desktop multi-range Turbidity Meter (EPA standard)Specifications
| LIST | VALUE |
|---|---|
| Measurement range - turbidity nonlinearity | 0.00 to 9.99、10.0 to 40.0NTU;0.0 to 99.9NTU、100 to 268Nephelos;0.00 to 9.80 EBC |
| resolution | 0.01、0.1NTU;0.1、1Nephelos;0.01EBC |
| Measurement Accuracy - turbidity nonlinearity | Reading +/- 2% + 0.02 NTU (0.15 Nephelos; 0.01 EBC), |
| Measurement range - turbidity linearity | 0.00 to 9.99、10.0 to 99.9、100 to 4000NTU;0.0 to 99.9、100 to 26800Nephelos; |
| Resolution - turbidity linearity | 0.01、0.1、1NTU;0.1、1 Nephelos;0.01、0.1、1EBC |
| Measurement Accuracy - turbidity linearity | Readings +/- 2% + 0.02 NTU (0.15 Nephelos; 0.01 EBC); Readings +/- 5% (Readings > 1000 NTU; |
| range conversion | Automatic range conversion |
| Turbidity Repeatability | +/- 1% of the reading or 0.02 NTU (0.15 Nephelos; 0.01EBC), whichever is greater |
| minimum detection limit | <0.02 NTU(0.15 Nephelos;0.01 EBC) |
| Method/standard | Turbidity (90 °) or scattering turbidity (90 ° & 180 °), conforming to USEPA Method 180.1 and Standard 2130B |
| Measurement mode | Ordinary measurement, continuous measurement, average measurement |
| Calibrated mode | Manual calibration, built-in standard calibrating points: < 0.1, 15, 100, 750, 2000NTU |
| Optical inspection system | Custom Dedicated Receiver & Light source System |
| data management | USB Interface; 200 measurement Data storage |
| Power mode | 230V/50Hz, 20W; 15 minutes without any operation, it will automatically shut down |
| Operating Environment | 0 to 50 ℃ (32 to 122 ° F), RH max 95%, non-condensing |
| Size Weight | Host size: 230x200x145mm, host Weight: 2.5kg |
HANNA HI88703 Desktop multi-range Turbidity Meter (EPA standard) Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJIS K0801-1986
- ActiveJJF 1700-2018
- ActiveJJF 1571-2016
- ActiveGB/T 31401-2015
- ActiveGB/T 13200-1991
- ActiveHJ 1075-2019
- ActiveHJ 1075-2019


HI88703