HANNA HI93102 Portable multiparameter Tester (EPA standard)
Multiparameter measurement system, turbidity, chlorine, acidity pH, bromine, iron, iodine and cyanuric acid (CYAC) including a total of 7 water quality parameters, portable design, laboratory grade Measurement accuracy, widely used in water quality analysis, drinking water quality monitoring and other fields.
HANNAIntroduction
The multi-parameter measurement system can quickly measure a total of 7 water quality parameters including turbidity, chlorine, acidity pH, bromine, iron, iodine and cyanuric acid (CYAC). Portable design, laboratory-level measurement accuracy, widely used in water quality analysis, drinking water quality monitoring and other fields.
Complying with USEPA180.1 standard and Standard Method 2130B standard method, the microprocessor calculates the turbidity value through the light intensity reaching the photoDetector; it effectively corrects color interference, and has chromaticity compensation and automatic light source compensation functions to avoid light source Interference caused by fluctuations eliminates the need for frequent calibration.
Characteristics
Excellent optical system design and humanized operation ensure good calibration of the instrument;
Manual calibration, built-in standard calibration points: 0, 20NTU, in line with USEPA method;
Built-in standard curve calibration before leaving the factory, with CAL CHECK performance verification function;
GLP function, update and check calibration data, date, standards and other information at any time;
The reaction time between reagents and samples is consistent to ensure measurement accuracy;
High-precision measurement results, light source dust-proof measurement system, automatic shutdown power-saving mode.
HANNA HI93102 Portable multiparameter meter (EPA standard)Specifications
| LIST | VALUE |
|---|---|
| Measurement range - turbidity | 0.00 to 9.99NTU、10.0 to 50.0NTU |
| Resolution - turbidity | 0.01NTU (≤9.99NTU)、0.1NTU(≤50.0 NTU) |
| Measurement Accuracy - turbidity | +/- 5%/0.5NTU@25 ℃/77 ° F whichever is greater |
| Measuring method - turbidity | Turbidity (90 ℃) or scattering turbidity (90 ℃ & 180 ℃), conforming to USEPA Method 180.1 and Standard 2130B |
| Calibrated mode - turbidity | Two-point calibrated, 0.00--50.0FTU optional, 0.00 and 20.0FTU standard points recommended |
| Measurement range -PH | 5.9 to 8.5pH |
| Resolution-PH | 0.1pH |
| Measurement Accuracy @25 ℃ -PH | ±0.1pH |
| Measurement range - residual chlorine | 0.00 to 2.50mg/L Cl2 |
| Resolution - residual chlorine | 0.01mg/L |
| Measurement Accuracy @25 ℃ - residual chlorine | +/- 3% of reading +/- 0.03mg/L |
| Measurement range - total chlorine | 0.00 to 3.50mg/L Cl2 |
| Resolution - total chlorine | 0.01mg/L |
| Measurement Accuracy @25 ℃ - total chlorine | +/- 3% of reading +/- 0.03mg/L |
| Measurement range - Cyanuric acid | 0 to 80mg/L Cys |
| Resolution - Cyanuric acid | 1mg/L(ppm) |
| Measurement Accuracy @25 ℃ - cyanuric acid | +/- 15% of reading +/- 1mg/L |
| Measurement range - Iodine | 0.0 to 12.5mg/L l2 |
| Resolution - Iodine | 0.1mg/L(ppm) |
| Measurement Accuracy @25 ℃ - Iodine | +/- 5% of reading +/- 0.1mg/L |
| Measurement range - Bromine | 0.00 to 8.00mg/L Br2 |
| Resolution - Bromine | 0.01mg/L(ppm) |
| Measurement Accuracy @25 ℃ - Bromine | +/- 3% of reading +/- 0.08mg/L |
| Measurement range - Iron | 0.00 to1.00mg/L Fe |
| Resolution - Iron | 0.01mg/L(ppm) |
| Measurement Accuracy @25 ℃ - Iron | +/- 3% of reading 0.02mg/L |
| Optical inspection system | Custom Dedicated Receiver & Light source System |
| Measuring method -pH | Colorimetry of phenol red, acidity reagent reacts with acidic substances in red; iron-Fe: using TPTZ method, iron reacts with reagent in light blue |
| Measuring method - total nitrogen | Refer to USEPA method 330.5 and Standard Method 4500-Cl G. with DPD reagent, the reaction is light pink; |
| Measuring method - Cyanuric acid | Refer to Nephilometry. Cyanuric acid reacts with reagents to form white suspended solids; bromine, iodine: in line with EPA, DPD methods |
| Power mode | 4X1.5VAA battery; automatic shutdown time setting: 10, 20, 30, 40, 50, 60 minutes |
| Miscellaneous indicators | 0 to 50 ℃ (32 to 122 ° F); RH max 95%, no condensation, host size: 220x82x66mm, Weight: 510g |
HANNA HI93102 Portable multiparameter meter (EPA standard) Packing list
machine X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI93102