SMART SENSOR AR4105B Ground Resistance Tester
Measurement range of ground Voltage 0~200V, ground Voltage error +/- 2% +/- 5dgt, resolution 0.1V, ground resistance Measurement range 20 Ω: 0~19.99 Ω; 200 Ω: 2~ 199.9 Ω; 2000 Ω: 20~1999 Ω, ground resolution 0.01 Ω~ 1 Ω, used for the measurement of ground resistance of various devices and the measurement of conductor resistance value and ground Voltage of low resistance.
SMART SENSOR-
SuJie ZJ-900 Mobile Air Self-purifier 820 * 610 * 120mm
$ 1188.00 -
Huicheng HCDR-S thermal conductivity Tester, high-low temperature thermal resistance performance test
$ 5045.00 -
AMITTARI AT-135B Stroboscopic Rotation speed instrument, stroboscopic instrument 50~40000FPM
$ 332.00 -
DUBAN DB25-204DJ Platts Penetration Meter & Fill Density Meter
$ 404.00 -
CHINA NBC-DB-501B DuPont Impact Tester 1m
$ 899.00
Introduction
AR4105B grounding resistance Tester is used to test the grounding resistance of various devices measured by electric power, post and telecommunications, railway, communications, mining and other departments, as well as to measure the conductor resistance value and ground Voltage of low resistance.
Grounding resistance refers to the resistance between the underground electrodes (such as grounding electrodes, grounding grids) and the ground in the grounding system, and it is one of the important parameters used to ensure the safety of electrical equipment and personnel. A ground resistance Tester calculates the value of the ground resistance by applying a specific current and measuring the Voltage drop in the grounding system.
Application
In the power system, the grounding resistance Tester is used to test the grounding system of power equipment, such as generators, transformers, power distribution devices, etc.
In the industrial production process, the grounding resistance Tester is used to test the grounding system of plants and equipment to ensure the safe operation of industrial equipment and the safety of the Operating Environment.
In construction engineering, the grounding resistance Tester is used to test the grounding system of the building, such as the grounding electrode, grounding grid, etc., to ensure the safety and reliability of the electrical system inside the building.
During the installation and maintenance of telecommunication equipment, the grounding resistance Tester is used to test the grounding system of telecommunication equipment and cables to ensure the normal operation of the communication system and the quality of communication.
In the railway system, the grounding resistance Tester is used to test the grounding system of electrical equipment such as railway signaling system and traction system to ensure the safety and reliability of railway transportation.
In the aerospace field, grounding resistance Testers are used to test the grounding system of aircraft, spacecraft and other equipment to ensure the safe operation of aircraft.
Packing specifications
| power supply | 6*1.5V AA battery/9V DC R6P(SUM-3)x6 |
| Net weight of the product | 526g |
| Product dimensions | 175*125*66mm |
| Packing: | valise |
| Standard outer carton capacity | ---- |
| Standard outer box size | ---- |
| Standard outer box gross weight | ---- |
SMART SENSOR AR4105B Grounding resistance TesterSpecifications
| LIST | VALUE |
|---|---|
| Measurement mode | 2-Line method/3-line method |
| Measurement range of ground Voltage | 0~200V |
| ground Voltage error | ±2%±5dgt |
| Resolution | 0.1V |
| Measurement range of grounding resistance | 20Ω : 0 ~ 19.99Ω;200Ω : 2 ~ 199.9Ω;2000Ω : 20 ~ 1999Ω |
| Grounding resistance error | ±(2.0%+0.1Ω);±(2.0%rdg+3dgt);±(2.0%+3dgt); |
| Grounding resolution | 0.01Ω~1Ω |
| Response time | Ground resistance: about 5 seconds; ground Voltage: about 2 seconds |
| Application standard | 1:IEC 61010-1 overVoltage CAT 330V PollutionDegree 2;2:IEC 61010-2-31;3:lEC 61557-1,5;4:IEC 60529(IP54) |
| Continuous measurement | Continuous measurement of all gears |
| insulation resistance | 500V wire to rubber shell ≥ 5MΩ |
| withstand Voltage | Wire to rubber shell 1500V AC 1 minute without jumping |
| Overload protection | Ground resistance range: 200V AC in (10 seconds); ground Voltage range: 300V AC in (30 seconds) |
| Environmental temperature | 0~40 ℃ (Humidity ≤ 85% RH) |
| Environmental temperature storage | -20~60 ℃ (Humidity ≤ 90% RH) |
| backlit display | Yes. |
SMART SENSOR AR4105B Grounding resistance Tester Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- How does the surface coating prevent corrosion?
- Study on electrical performance of powder coatings
- Box type resistance furnace calibration method and steps
- Matters needing attention and instrument maintenance of Martindale resistance test
- Application of low/high Temperature Test Chamber in resistance high-low temperature test
- How to choose the right size disperser?
- How does resistivity change during curing?
- What is surface resistivity?
- Box type resistance furnace - temperature magician in industry
- Comparison of material resistance/Electrical resistivity test methods


AR4105B






