      Home> Cryogenic coolant circulating pump> HuXi> HuXi HLS-1312F High-precision chiller
      HuXi HLS-1312F High-precision chiller

      HUXI HLS-1312F high-precision chiller 13L/1200W

      Water tank volume 13L, Temperature range 5-35 ℃, Stability +/- 0.1 ℃, refrigeration power 1200W, pump Flow rate 4L/min@1.5bar

      Brand
      SKU: NB046601
      China HuXi
      Stock
      Loading…
      Price
      $ 1607.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • HuXi HLS-1312F High-precision chillerOverview

        • Specifications
        • Comments
        • FAQs
        HLS-1312F
        High-precision chiller
        • HUXI HLS-1312F high-precision chiller 13L/1200W
        Water tank volume 13L, Temperature range 5-35 ℃, Stability +/- 0.1 ℃, refrigeration power 1200W, pump Flow rate 4L/min@1.5bar

        Introduction

        The high-precision chiller is a high-end model designed for the needs of high-quality analytical instruments, which is mainly used in the fields of atomic absorption instrument, spectrometer, mass spectrometer, scanning electron microscope, lens electron microscope, Soxhlet extractor, diffusion pump, molecular pump, Kjeldahl nitrogen meter, ion thinning instrument, Fourier transform mass spectrometry (FIS), magnetron sputtering instrument, small vacuum coater and other analytical instruments.

        Features

        • High-performance circulating water pump, the pressure of the Circulating Chiller is steplessly adjustable;

        • Detachable dust net cover, maintenance is very convenient, user operation is easier, installation and debugging are more convenient and fast;

        • The refrigeration function and circulation function can be controlled independently or simultaneously;

        • The combination of proportional refrigeration technology, hot gas bypass technology and PID control technology has high temperature control accuracy;

        • Temperature protection, water pressure protection, overheating and overcurrent protection and other multiple safety protections to ensure the safety of experiments;

        • A variety of operation modes are available, and the unexpected power failure can be automatically restored, which can ensure the continuous supply of cooling circulating water;

        • The imported compressor and ultra-quiet fan are used to make the noise of the whole machine very low, especially suitable for laboratory environment;

        • Alarm reminder function, light and sound reminder at the same time when alarming, the code is directly displayed, and the error point can be directly determined;

        • Multiple purification water quality design: a filtration device is configured in the primary Water Tank to purify water quality; The careful selection of the material of the double waterway ensures the cleanliness of the water in the pipeline; Triple standard water filter for purification to meet the water quality requirements of external analytical instruments.

        VS

        HuXi HLS-1312F High-precision chillerSpecifications

        LIST VALUE
        Model small
        Power Supply 220V/50Hz
        cooling Capacity 1200W
        Refrigerant R22
        freezing Capacity 1200w
        Compressor type Rotor compressor
        Input Power 0.45Kw
        Refrigerant type R22
        Condenser type finned
        air Volume 560m²/h
        Type of evaporator Stainless steel coil
        Water tank Volume 13L
        Temperature control type start stop
        Humidity range 5-35℃
        Temperature Accuracy 0.1℃
        Temperature display liquid crystal
        Pump type diaphragm pump
        Power 100W
        rated pressure 1.5bar
        Rated head 15m
        Flow rate 4L/minr
        maximum pressure 4bar
        Flow rate 5L/min
        Water inlet and outlet pipe diameter DN15
        Rated Power 500W
        Shell material Q235 spray
        Instrument size 400x550x670mm
        Packaging Dimensions 470x620x850mm
        Net Weight of instrument 46kg
        Instrument Gross Weight 55kg

        HuXi HLS-1312F High-precision chiller Packing list

        Host X1, power cord X1, manual X1, certificate X1, warranty card X1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        The atomic absorption instrument in our laboratory needs to be equipped with a chiller. Is there any recommendation?
        [A]
        HUXI HLS-1312F high-precision chiller is recommended. It is designed for analytical instruments such as atomic absorption meters, using proportional refrigeration and PID temperature control technology, with a temperature accuracy of 0.1 ° C to ensure stable operation of the instrument. Multiple water purification designs can also meet the strict requirements of atomic absorption meters for water quality.
        [Q]
        SEM Laboratory Environmental requirements Quiet, chiller noise?
        [A]
        HUXI chiller is suitable for laboratories. It uses imported compressor and ultra-quiet fan, and the noise is very low during operation, which will not interfere with the precise operation of sem. At the same time, it has multiple Safety protection to ensure the safety of valuable instruments.
        [Q]
        The atomic absorption instrument in our laboratory needs a chiller. Do you have any recommendations?
        [A]
        The HLS-1312F high-precision chiller is specially designed for analytical instruments such as atomic absorption meters, with a temperature control accuracy of 0.1 ° C, which can ensure the stable operation of the instrument and avoid temperature fluctuations affecting the detection results.
        [Q]
        Light spectrum instrument laboratory has any special requirements for chillers?
        [A]
        Light spectrum instrument needs continuous and stable chill down, HUXI this chiller uses proportional refrigeration and PID control technology, precise temperature control, and multiple protection and water purification design, can effectively protect the precision Optical inspection components.
        HuXi
        HUXI HLS-1312F high-precision chiller 13L/1200W
        Service
        Focus on online sales of Lab Testing Instruments