HUXI Nano-900 UV-Visible, ultra-micro Spectrophotometer Light spectrum instrument
Wavelength range: 180~910nm, sample volume requirements: 0.5μL~ 2μL, recommended 2μL, Light source/life: Light source/life, Optical path: 0.05mm, 0.2mm, 1mm
HuXi-
JINGHUA UV1800PC UV-Visible Spectrophotometer Wavelength range: 190nm~ 1100nm
$ 2504.00 -
JINGHUA 722S visible spectrophotometer high resolution low stray light, wide sample room
$ 357.00 -
JINGHUA 7600CRT Dual beam of light UV-Visible Spectrophotometer High Accuracy Light spectrum analyzer, standard computer/printer
$ 5420.00 -
JINGHUA H300 Dual beam of light Spectrophotometer Wavelength range 190nm-1100nm
$ 2747.00 -
JINGHUA 755B Automatic UV-Visible Spectrophotometer High Performance Grating, Large Sample Chamber
$ 1499.00
Applications
● Spectrophotometer, also known as spectrometer, is an instrument that uses spectrophotometry to quantitatively and qualitatively analyze substances, and is often used for the quantification of nucleic acids, proteins and bacterial growth concentrations.
● Nano-900 is a UV-Vis Spectrophotometer , which is specially designed for micro-volume analysis of purified nucleic acids and a variety of proteins, with a minimum volume of 0.5μL for each test sample, and the concentration of the detected sample is hundreds of times that of the standard cuvette.
Features
● Intelligent Android operating system, 7-inch capacitive touch screen, multi-touch, dedicated APP interface is more intuitive and user-friendly design;
● Cuvette slot, more convenient for the detection of bacteria/microorganisms and other culture medium concentrations;
● The instrument does not need to be connected to the computer, and the single machine can complete the sample detection and data storage;
● Image and table storage format: The table is compatible with Excel, which is convenient for subsequent data processing, and supports JPG image export;
● Driven by high-precision linear motor, the accuracy of the optical path reaches 0.001mm, and the absorbance detection is repeatable;
● Only 0.5~2μl of sample is needed for each test, and the sample can be recovered after the measurement, so you can rest assured that you can study precious samples;
● The sample is directly placed on the sampling platform, without dilution, the measurable sample concentration is 50 times that of the conventional UV-Vis Spectrophotometer , and the detection and display results can be completed in 2s~6s, and the results are directly output as the sample concentration without additional calculation.
HuXi Nano-900 Ultra micro SpectrophotoMeter Specifications
| LIST | VALUE |
|---|---|
| Power | 48W |
| sample size | 0.5 μL to 2 μL, 2 μL is recommended. |
| optical path | 0.05mm、0.2mm、1mm |
| Light source/lifetime | Flashing xenon arc/number of flashes 109 |
| Detector type | 2048-Cell Linear CMOS Array |
| Wavelength range | 180~910nm |
| Wavelength resolution | ≤1.5nm(FWHM@Hg253.7nm) |
| Absorption precision | 0.002Abs (1mm optical path) |
| wavelength reproducibility | ±0.2nm |
| Sample wavelength scanning | 180-910nm |
| Absorbed Light Accuracy | ±1%(7.332Abs at 260nm) |
| Absorption range | 0.02~ 300A (at 260nm wavelength, equivalent to 10mm optical path) |
| Nucleic acid test concentration range | 2-15000ng/ul(dsDNA) |
| Protein concentration detection range | BSA 400mg/ml;IgG 290mg/ml |
| detection time | <6s |
| OD600 Absorption Range | 0~4.000Abs |
| OD600 Absorption Stability | [0,3)≤0.5%,[3,4)≤1.5% |
| OD600 Absorption Repeatability | [0,3)≤0.5%,[3,4)≤1.5% |
| OD600 Absorption Accuracy | [0,2)≤0.005A,[2,3)≤1%,[3,4)≤2% |
| Light spectrum Bandwidth | ≤1.5nm |
| Light spectrum resolution | ≤1.5nm(FWHM@Hg253.7nm) |
| Photometric Accuracy | 0.002Abs (1mm optical path) |
| Base measurement only | 0.5—2ul |
| Sample base material | Quartz fiber and 304 stainless steel |
HuXi Nano-900 Ultra micro SpectrophotoMeter Packing list
Host X1, power cord X1, Colorimetric dish X1, U disk X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
HuXi Nano-900 Ultra micro SpectrophotoMeter Library
FAQ
- UV-Visible Spectrophotometer for Evaluating Light spectrum Transmittance of Agricultural Conversion Films
- Determination of Colorless Transparent Adhesive light transmitance by UltraViolet-visible Infrared spectrophotometer
- Determination of free formaldehyde content in Aqueous Adhesive by UV spectrophotometer
- UV spectrophotometer measurement Water-based ink concentration
- Application of ultraviolet spectrophotometer in detection of inks harmful substances
- Spectrophotometer principle, structure and application do you know geometry?
- Thin film light transmitance spectrophotometer and its application
- Spectrophotometer 100% T Uncalibrated light path inspection
- Core Application of Spectrophotometer in Inks Color Precise Control
- Difference analysis of single beam of light and double beam of light in spectrophotometer selection
- ActiveGB/T 46828.1-2025
- ActiveGB/T 713.2-2023
- ActiveGB/T 23850-2024
- ActiveSL/T 788.4-2019
- ActiveSL/T 788.5-2019
- ActiveSL/T 788-2019
- ActiveHJ 668-2013
- ActiveSL/T 788.1-2019
- ActiveGB/T 6730.89-2024
- ActiveJJF 1836-2020
- ActiveHB 20056.1-2011
- ActiveYB/T 4217.1-2010
- ActiveJG/T 235-2014
- ActiveJC/T 1040-2020
- ActiveSH/T 0409-1992
- ActiveSL 84-1994
- ActiveJY/T 0570-2020
- ActiveHJ 601-2011
- ActiveQX/T 216-2013
- Active 01010102-2006