3NH DS360 portable Colorimeter φ 8mm/φ 10mm
Lighting mode: D/8, integrating sphere size φ 40mm, Lighting source combination Full Light spectrum LED Light source, spectroscopic mode Plane grating spectroscopy, sensor silicon photodiode array (dual 32 groups), measurement Wavelength range 400~700nm, storage data master standard 1000, sample 20,000.
3NH-
CHNSPEC CS-826 high-precision image Colorimeter high conformity
$ 20249.00 -
3NH NBC60 Colorimeter 8mm/4mm
$ 3491.00 -
3NH YL4668 D/8 Non-contact desktop Colorimeter automated production line
Login -
3NH Colorimeter TOP color difference treasure, special edition, Measurement
$ 319.00 -
3NH ST-700D Plus Array Colorimeter with five calibers
$ 3149.00
Introduction
Spectrophotometer is a portable Spectrophotometer developed by using independent Spectrophotometer core technology, which not only ensures the accurate relative value △E, but also ensures the accuracy of the absolute value L, A and B for a long time, and can pass the measurement of international standards and national standards anytime and anywhere.
Features
It adopts the internationally accepted D/8 SCI/SCE synthesis technology.
The all-band equalization LED light source instrument is used to measure the speed and accuracy of the measurement results.
Silicon photodiode array (dual 32 array) sensor.
A variety of color measurement spaces and a variety of observation light sources can meet the special measurement needs under different measurement conditions.
Each instrument has a metrological verification report to ensure the reliability of the instrument's test data.
Featuring the innovative ETC real-time calibration technology (Every Test Calibration).
The camera is positioned for a clear view of the area to be measured.
With CQCS3 quality management software, more extended functions can be realized.
Application industry
Spectrophotometer is widely used in plastics, electronics, paints, inks, textile and garment printing and dyeing, printed paper, automobiles, medical, cosmetics and food industries.
SCI supports a variety of sample measurements, accurate data, easy to use, and is a practical tool for color detection in production, quality control, etc.
3NH DS300 Portable ColorimeterSpecifications
| LIST | VALUE |
|---|---|
| Lighting method | D/8 (diffuse illumination, 8 ° direction reception), SCI/SCE measurement conforms to CIE No. 15, GB/T3978, GB2893, GB/T18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 |
| Integrating sphere size | φ40mm |
| lighting source | Light spectrum LED light source |
| spectroscopic mode | Plane grating spectroscopy |
| Sensor | Silicon photodiode array (dual row 32 groups) |
| Measurement Wavelength range | 400~700nm |
| wavelength interval | 10nm |
| Half bandwidth | 10nm |
| Measurement range | L: 0~120 reflectance: 0~200% |
| Measurement caliber | Single diameter: phi 8mm/phi 10mm |
| Light-containing method | Simultaneous testing of SCI/SCE |
| Color Space | CIE LAB,XYZ,Yxy,LCh,s-RGB,βxy,Munsell(C/2) |
| color difference formula | △E*ab,△E*94,△E*cmc(2:1),△E*cmc(1:1),△E*00,DIN△E99 |
| Miscellaneous chroma index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), homochromatic index Mt, colour fastness, fastness to color change, force, coverage, Formula Guide |
| Observer Angle | 2°/10° |
| observation light source | D65,A,C,D50,F2(CWF),F7(DLF),F10(TPL5),F11(TL84),F12(TL83/U30) |
| show | Light spectrum graphs/data, sample chromatic values, color difference values/graphs, pass/fail results, Color simulation, Color bias |
| Measurement time | Approximately 1.5s (approximately 3.2s for simultaneous SCI/SCE testing) |
| Sexual repeability | Chromatic value: MAV/SCI, Delta E * ab within 0.06 (after preheating correction, the average value of 30 whiteboard measurements at intervals of 5s) |
| Inter-instrument Agreement | MAV/SCI, Delta E * ab within 0.3 (BCRA series ⅱ 12 color plate measurement average) |
| Measurement method | Single measurement, average measurement (2~ 99 times) |
| positioning method | Display camera viewfinder positioning, stabilizer positioning |
| size | Length X width X height = 81X71X214mm |
| Weight | Approx. 500g |
| Battery level | Lithium battery, 6000 cycles in 8 hours |
| Lighting source life | More than 3 million measurements in 5 years |
| Display | TFT true color 3.5inch, capacitive touch screen |
| interface | USB |
| store data | 1000 master standards, 20,000 samples (one data can include SCI/SCE at the same time) |
| language | Simplified Chinese, English, Traditional Chinese |
| Operating temperature range | 0~40 ℃, 0~85% RH (no condensation), altitude: less than 2000m |
| Storage temperature range | -20~50 ℃. 0~85% RH (no condensation) |
| standard attachment | power adapter, data cable, manual, SQCX quality management software, black and white correction box, protective cover, wristband, 08mm platform diameter, 08mm pointed diameter |
| optional accessories | USB micro printer, powder test box |
3NH DS300 Portable Colorimeter Packing list
host X1, manual x1, certificate of conformity x1, warranty card x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


DS300