Search
    Cart(0)
      总价
      前往结算
      您的购物车是空的 : )
      Home> Viscosity Cup> TQC sheen> TQC sheen VF2077 Viscosity cup

      TQC VF2077 immersion Viscosity Cup 8mm filter

      Viscosity cup, aluminium. DIN 53211 with fixed nozzle 8mm

      Brand
      SKU: NB004719
      Netherlands TQC sheen
      Model
      Stock
      Loading…
      Price
      $ 354.00
      Promotion
      Service
        Service
        The delivery and service By NBchao.Com
        VS
        Genuinegoods
        • TQC sheen VF2077 Viscosity cupOverview

        • Specifications
        • Comments
        • FAQs
        VF2077
        Viscosity cup
        • TQC VF2077 immersion Viscosity Cup 8mm filter
        • TQC VF2077 immersion Viscosity Cup 8mm filter Figure 1
        • TQC VF2077 immersion Viscosity Cup 8mm filter Figure 2
        Viscosity cup, aluminium. DIN 53211 with fixed nozzle 8mm

        TQC immersion Viscosity CupIntroduction

        TQC immersion Viscosity Cup is a kind of Viscosity Cup is designed with a long handle on one side of the Viscosity Cup, it is very convenient to measure the viscosity of the coating, just need to carry the Viscosity Cup into the paint with one hand, fill it with the paint, lift it to measure the viscosity value, you can control the viscosity value determination well, and the accuracy is high. This TQC immersion Viscosity Cup is made of aluminum alloy, and the filter is made of stainless steel. TQC dipstyleViscosity cups are suitable for viscosity testing of most coatings,

        rootThe TQC immersion Viscosity Cups are available in VF2071, VF2072, VF2073, VF2074, VF2075 and VF2077 with different filter diameters. The TQC immersion Viscosity Cup complies with DIN 53211 and is suitable for detecting viscosity values in coatings, inks and other industries.

        TQC immersion Viscosity Cup

        Technical parameters

        ModelFilter diameterFlow timeViscosity range
        VF20712mm

        VF20723mm

        VF20734mm25-150sec96-683cst
        VF20745mm

        VF20756mm

        VF20778mm

        Other parameters
        Cup body materialTitanium anodized aluminum, 100cc
        Spout and retainer materialstainless steel
        Meets standardsApproximate to DIN 53211
        weight176~179 grams
        Maximum width63mm
        height74mm
        Total height250mm
        typeDip/handheld

        How to use:

        1) According to the standard, the temperature of the liquid to be measured is 23 degrees Celsius, and the temperature fluctuation needs to be minimized and cannot exceed +/- 0.2 degrees Celsius during the test.

        2) Adjust the temperature of the liquid to be measured if necessary.

        3) According to the specification table and the expected viscosity range of the liquid to be measured, select the appropriate pore sizeTQC immersion Viscosity Cup.

        4) WillThe TQC immersion Viscosity Cup slowly dips into the paint viscosity until the top edge of the cup is able to submerge.

        5) Put a thermometer into the Viscosity Cup and measure the temperature of the test sample.

        6) Remove the thermometer.

        7) Hook the handle ring with your fingers to keep the cup vertical. Maintain a steady state and quickly lift the Viscosity Cup from the sample when TQCThe immersion Viscosity Cup leaves the surface of the test paint to start the timer. During the liquid flow process, the Viscosity Cup should be kept above the surface of the sample, no more than 15 cm.

        8) Stop the timer when the liquid flow beam is interrupted for the first time.

        Maintenance method:

        1. It is especially important to clean the outflow hole to remove residue and avoid scratching its inner surface.

        2. Although the Viscosity Cup is designed to be strong, it is a precision instrument and should not be dropped or impacted.

        3. It needs to be cleaned after use.

        4. Please use soft cloth to clean the Viscosity Cup, and do not use such as wire brush or sandpaper. This is because this can be caused by corrosive cleaning agentsLong-lasting damage.

        5. Do not directly tap the spout when disassembling the spout. Use the pin rod supplied with the Viscosity Cup against the spout before tapping with a heavy object (e.g., a paperweight).

        6. Before installing the cup spout, please make sure that the cup spout and Viscosity Cup are clean.

        7. When not in use, please useTQC immersion Viscosity CupPut it back in the box.

        8. We recommend calibration once a year.

        9. RightTQC immersion Viscosity CupThe maintenance can ensure the accuracy of the experiment

        Product detail drawing

        Netherlands TQC aluminum alloy immersion Viscosity Cup real picture 1

        Netherlands TQC aluminum alloy immersion Viscosity Cup real shot 2

        Netherlands TQC aluminum alloy immersion Viscosity Cup real shot 3

        Real shot of VF2073 Viscosity Cup

        Holland TQC Viscosity Cup automatic production process

        Standardized production process of Dutch TQC Viscosity Cup

        TQC Model Selection Table

        Dutch TQC Viscosity Cup selection table 1

        The maximum viscosity value and the minimum viscosity value of the TQC Viscosity Cup are .png

        Take you to the Dutch TQC

        Historical development of TQC company

        TQC automatic production and strict quality control

        TQC R&D team

        VS

        TQC sheen VF2077 Viscosity cupSpecifications

        LIST VALUE
        flow hole diameter 8mm
        Capacity 100ml
        Cup height 74mm
        Maximum width 63mm
        Total height 250mm
        Cup body material Titanium anodic oxidation aluminum
        Filter material stainless steel
        Handle material Titanium anodic oxidation aluminum
        Applicable standards Approximate DIN 53211
        Certificate without
        Weight 176~179g

        TQC sheen VF2077 Viscosity cup Packing list

        Viscosity cup x1, Encasement box x1, Manual x1

        [Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.

        FAQ

        [Q]
        Epoxy resin Coating viscosity measurement with what material Viscometer is better?
        [A]
        Measurement Coating viscosity generally can choose viscosity cup or Viscometer, viscosity cup mainly measures relative viscosity, Viscometer measures dynamic viscosity. In general, in addition to thixotropic Coating, Coatings under 150s can be coated with 4 cups, and Coatings under 20 can be coated with 1 cup. In addition, Yehui uses ISO flow cup to measure Newton-type liquid Coating viscosity, Stormer Viscometer to measure architectural coatings viscosity, and for all brush coatings, rotational viscometer or Cone and Plate Viscometer measurement can be used.
        [Q]
        Do you have the viscosity cup involved in JJG743?
        [A]
        The VF2077 viscosity cup will do
        TQC sheen
        TQC VF2077 immersion Viscosity Cup 8mm filter
        Service
        Focus on online sales of Lab Testing Instruments