TASI TASI-655 salt meter, salt range: 0.1%~ 10% salt and temperature double display
The TASI-655 salt meter is a digital portable salt meter with dual salt and temperature measurement functions. The salt measurement range is 0.1% to 10%. The TASI-655 has automatic temperature compensation.
TASI-
KeDiDa CT-3086 Pen Salinometer Inductive built-in electrode Range: 0.0~5.0%
$ 127.00 -
SALscan20 Salinometer Conductivity Detector 0.00~80.00ppt
$ 161.00 -
SMART SENSOR AR8012 Written test Salinometer portable high-precision salinity temperature measurement
$ 106.00 -
Kodida CT-3081 Pen Salinometer measuring range: 0~9999MG/L
$ 124.00 -
HANNA HI98203D salinity meter 0.00~1.00pNaCl
$ 279.00
TASI-655 Salt Meter Features
◆ Easy to carry, one-handed operation
◆ Backlit display function
◆ Salt and temperature double group display
◆ Automatic temperature compensation
◆ Average value calculation (up to once every 9 transactions), continuous measurement (according to the set time interval), conversion of the relative salt amount in the liquid
◆ High-precision NTC temperature sensor
◆ Automatic shutdown function
◆ CE certification qualified
Maintenance matters
After measuring the salt solution, be sure to rinse the TASI-655 Salt Meter Test Rods with clean water, and wipe the test rods clean before the protective cover can be closed.
After use, be sure to wash the test rod with clean water, wipe it clean with a flexible cloth, and then close the protective cover.
Product display diagram



TASI TASI-655 Salt meterSpecifications
| LIST | VALUE |
|---|---|
| Temperature Specifications - Sensors | Thermistor temperature sensor |
| Temperature Specifications - Range | -20℃~60℃,-4℉~140℉ |
| temperature resolution | 0.1℃,0.1℉ |
| Temperature Accuracy | +/- 0.5 ℃ at 0 ℃ to 45 ℃; +/- 1 ℃ at -20 ℃ to 0 ℃, 45 ℃ to 6 0 ℃; +/- 1 ° F at 32 ° F to 113 ℉; +/- 2 ° F at -4 ° F to 32 ° F, 113 ° F to 140 ° F |
| Measurement range | 0.1%~10% |
| Salt specification - temperature compensation | -5 ℃~ 60 ℃ (automatic) |
| Salt Specifications - Accuracy | 0%~ 0.9 % ( +/- 0.1); 1.0%~ 1.9 % ( +/- 0.2); 2.0%~ 2.9 % ( +/- 0.3) 3.0%~ 4.9 % ( +/- 0.5) 5.0%~ 7.9 % ( +/- 1.0); 8.0% to 10.0 % ( +/- 1.5, depending on the measurement method) |
| Low battery Voltage display | When the battery Voltage is lower than the operating Voltage, "+ -" is displayed. |
| Operating environment | 0 ℃ to 50 ℃, Relative Humidity < 75% R.H. |
| Storage environment | -20 ℃ to 60 ℃, 0 to 80% R.H. |
| Accuracy test environment | 23 ℃ +/- 5 ℃, Relative Humidity < 75% R.H. |
| size | 178mm(高)x65.5mm( |
| Weight | Approx. 320g |
TASI TASI-655 Salt meter Packing list
host x1, manual x1, battery x1, certificate x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- Measurement of film salt fog resistance
- How to make anti-salt spray determination?
- How is film salt spray resistance measured?
- TASI655 Digital Salinometer Operating Instructions


TASI-655