DUBAN DB13-934-1 Babbitt Hardness Gauge Measurement range 0~100HBa
Measurement range 0~100HBa, equivalent to 25~ 150HBW, resolution 0.1HBa, error of indication 81~ 88HBa +/- 1HBa, Repeatability Error 81~ 88HBa +/- 1.5HBa, with MAX Maximum hold function.
Duban-
AMITTARI AW-20A Webster Hardness Tester Aluminum alloy, thick 0.6-13 inner diameter > 10
$ 520.00 -
LANDTEK HM-934-1 digital display pasteur Hardness Gauge special indentation Hardness Tester for aluminum industry
$ 551.00 -
LEEB W-20 Webster Hardness Tester measuring aluminum alloy, workpiece size thickness 0.4~ 6mm
$ 459.00 -
HBO LX-DO rubber Hardness Gauge for medium Hardness materials
$ 176.00 -
Pap Hardness Gauge BA-2 Hypertherm, Pap Hardness Tester
$ 856.00
Introduction
DB13-934-1 and DB13-934-1+ digital display Pap Hardness Tester are newly designed and developed indentation Hardness Testers. It is mainly used in the aluminum processing industry. It is used to test pure aluminum, soft aluminum alloy, thicker aluminum alloy, aluminum plate and strip, aluminum profile, aluminum rod, aluminum casting, aluminum forging and aluminum alloy products; It can also be used in the FRP industry. The relevant industry standards are ASTM B648-10 (2015) "Standard Test Method for Measuring Indentation Hardness of Aluminum Alloys by Baco Indentation Hardness Tester", ASTM D2583-13 "Standard Test Method for Barker Hardness of Rigid Plastics" and GB/T 3854-2005 "Standard Test Method for Barker Hardness of Rigid Plastics" and GB/T 3854-2005 "Test Method for Barker Hardness of Reinforced Plastics".
Features
The Barcol hardness value (HBa) of the material can be measured.
The design of the meter is small, lightweight, one-handed operation, one pressure can be, no experience is required, as long as it is within reach, it can be used on any occasion.
Wide range of tests. It can be tested from very soft pure aluminum to particularly hard aluminum alloy, and the effective test range is equivalent to Brinell hardness 25~150HB.
No support required. The Barcol Hardness Tester is only tested on one side of the specimen and does not require support, making it suitable for testing oversized and oversized workpieces and assemblies.
It has a maximum value hold function to record the maximum hardness value during the measurement.
DB13-934-1+ can additionally measure Brinell hardness (HB) and Vickers hardness values of materials
(HV), Webster Hardness value (HW), Rockwell hardness value (HRB/HRE/HRF/HRH).
DB13-934-1+ has the average value calculation function, which can calculate the average of up to 29 sets of data.
Serial models
| Model | DB13-934-1 | DB13-934-1+ |
| Measuring range | 0~100HBa, equivalent to 25~150HBW | |
| resolution | 0.1HBa | |
| Indication error | 81~88HBa ±1HBa | |
| 42~48HBa ±2Hba | ||
| Repeatability Error | 81~88HBa ±1.5HBa | |
| 42~48HBa ±2.5HBa | ||
| Brinell hardness measurement | √ | |
| Vickers hardness measurement | √ | |
| Webster Hardness measurement | √ | |
| Rockwell hardness measurement | √ | |
| Maximum value hold function | √ | √ |
| Average value calculation function | √ | |
| Operating Environment | Temperature: 0~50°C Humidity: <80%RH | |
| power supply | 2 x No. 7 batteries | |
| size | 170x63x82mm | |
| Weight (without battery) | 390g | |
| Optional | —— | Bluetooth adapter and software |
Duban DB13-934-1 Pasteur Hardness GaugeSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 0~100HBa, equivalent to 25~ 150HBW |
| resolution | 0.1HBa |
| error of indication | 81~88HBa ±1HBa |
| Repeatability Error | 81~88HBa ±1.5HBa |
| MAX Maximum Hold Function | Yes. |
| Operating Environment | Temperature: 0~50 ℃; Humidity: < 80% RH |
| Power Supply | 2 AA batteries |
| size | 170x63x82mm |
| Weight (without battery) | 390g |
Duban DB13-934-1 Pasteur Hardness Gauge Packing list
Host X1, spare pressure needle X2, standard Hardness block X2, small screw driver X1, small wrench X1, portable case X1, instruction manual X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


DB13-934-1