KAIRDA NDT3710 + electromagnetic ultrasonic Thickness Gauge detection range 1-250mm
Detection range 1-250.0mm, measurement equipment error range When the workpiece thickness is < 10mm, the error is +/- 0.05mm; when the workpiece thickness is > 10mm, the error is + (0.01 + H/200) mm (H is the workpiece thickness value), indication Repeatability 0.8% (HLD = 800), receiving gain ≤ 100dB, lifting gap 0~2.5mm, probe maximum tilt angle +/- 25 °.
KairDa-
Steel plate Ultrasonic Thickness Gauge DC-3000C, penetration coating measurement material Film thickness
$ 1312.00 -
DONGRU DR85S Ultrasonic Thickness Gauge 400mm/0.01mm
$ 168.00 -
PRUT310 Ultrasonic Thickness Gauge Display Resolution 0.001mm
Login -
Ultrasonic Thickness Gauge DC-1000C Ultrasonic measurement Film thickness
$ 560.00 -
DUBAN DB22-TM240B high-precision Ultrasonic Thickness Gauge 300mm/0.01mm
$ 542.00
The NDT3710+ EM Thickness Gauge is an ultra-small, acoustic couplant-free, non-contact thickness Measurement Instrument for thickness measurement of metals or magnetically conductive materials.
Features
Small in size and easy to carry.
The console can be wirelessly connected to the tablet.
The requirements for the surface of the workpiece are not high, and there is no need for grinding treatment on rough surfaces, and non-contact measurement can be realized.
Coating-insensitive enables thickness measurement of coated workpieces.
Acoustic couplant is not required, and thickness measurement of high-temperature workpieces can be realized, and temperature compensation is possible.
KairDa NDT3710+ Electromagnetic ultrasonic Thickness GaugeSpecifications
| LIST | VALUE |
|---|---|
| detection range | 1-250.0mm |
| Can detect workpiece material | Carbon steel, cast steel, alloy steel, stainless steel, copper, aluminum, titanium and other conductor materials |
| Measurement equipment error range | When the workpiece thickness is < 10mm, the error is +/- 0.05mm; when the workpiece thickness is > 10mm, the error is + (0.01 + H/200) mm (H is the workpiece thickness value) |
| Indication Repeatability | 0.8%(HLD=800) |
| Receive gain | ≤100dB |
| lift-off gap | 0~2.5mm |
| Probe maximum tilt angle | ±25° |
| Probe excitation method | permanent magnet |
| Sound wave type | Shear wave (shear wave) |
| high temperature compensation | Speed of sound automatic compensation function |
| Speed adjustment range of sound waves | 1000-9999m/s |
| waveform display | Positive half wave, negative half wave, full wave, RF wave, envelope wave |
| Power Supply | Built-in lithium battery, Working time is not less than 5 hours |
| Operating temperature range | -10~+50℃ |
| Host Storage Temperature range | 0-+40℃ |
| Host Weight | 250G (with room temperature probe) |
| Dimensions (length × width × thickness) | 176×42×32mm |
KairDa NDT3710+ Electromagnetic ultrasonic Thickness Gauge Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


NDT3710+