RVDV-2H digital display Rotational Viscometer 10 million mPa · s 250 ℃
Specially measure the viscosity of solid-state objects heated to liquid at high temperature, with a range of 10 million CP, using embedded integrated heating, high-subdivision progress click, optional drawing analysis software, and full monitoring.
HuiNuo-
RVDV-1 digital Rotational Viscometer Viscosity Detector with L0 rotor
$ 1367.00 -
FANGRUI XHT double-layer glass Viscometer matching thermostatic cup, optional accessories
$ 141.00 -
HUINUO SNB-1 Digital Display Rotational Viscometer Viscosity Testing Instrument 600,000 CP Printer
$ 966.00 -
MODERNER NDJ-5S Digital Rotational Viscometer viscosity range: 1~ 100000mPa · s
Login -
HUINUO HBDV-2H digital display swirl/spin high temperature Viscometer 80 million mPa · s 250 ℃
$ 2502.00
Introduction
It mainly measures substances that are solid at room temperature and become liquid after heating at high temperature, such as asphalt, hot melt adhesive, polyethylene wax, etc.
It can be used as a stand-alone machine, and the measurement data is directly displayed on the LCD screen, without secondary calculation; It can also be equipped with optional "Data Acquisition Analysis and Drawing Software" to realize data acquisition and data analysis, and monitor the viscosity-temperature curve throughout the process.
The high-subdivision stepper motor is adopted, and the speed is accurate and stable.
The LCD liquid crystal with blue backlight function directly displays the viscosity, rotational speed, percentmeter torque, rotor number, and the maximum viscosity value and temperature value that can be measured by the selected rotor at the current speed. The DV-2 series can also display shear rate and shear stress. The viscosity value shows a continuous change, and there is an audible alarm when the measurement range is exceeded.
The measurement performance of the instrument has reached the level of the same type of foreign products through computer correction.
The high-temperature furnace adopts built-in integral heating, which is evenly heated and has small thermal inertia.
Instrument structure
DV-H series selection
| Model | LVDV-1H | RVDV-1H | HBDV-1H | LVDV-2H | RVDV-2H | HBDV-2H |
| Measuring range | 10~1M | 100~10M | 800~80M | 5~1M | 50~10M | 400~80M |
| (mPa · s) | ||||||
| Rotation speed | 0.1~99.9 continuously variable speed | 0.1~200 continuously variable speed | ||||
| (rv/min) | ||||||
| Rotor configuration | 1 rotor 21, 27, 28 and 29 each | |||||
| Measurement accuracy | ±1% (FS) Newtonian fluid | |||||
| Reproducibility | ± 0.5% (FS) Newtonian fluid | |||||
| Sample volume (mL) | 10~20 | |||||
| Temperature Control Range (°C) | Room temperature +10~250 | |||||
| Temperature Control Accuracy (°C) | ±0.1 | |||||
| power supply | 220V 50Hz | |||||
HuiNuo RVDV-2H Digital Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Display mode | digital display |
| Measurement range | 50~10000000mPa·s |
| Rotor specification | 21#、 27#、28#、29# |
| Rotor speed | 0.1~200rpm |
| Rotation speed Control mode | CVT |
| reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Capacity | 10~20mL |
| Temperature range | RT+10~250℃ |
| Temperature Accuracy | ±0.1℃ |
| Display information | Viscometer: Viscosity, Shear Rate, Shear Stress, Rotation speed, Temperature, Percentimeter torque, Rotor number and the maximum viscosity of the selected rotor at the current Rotation speed, etc. Temperature Controller: Set temperature and Measuring temperature display. |
| Power supply Voltage | 220V 50Hz |
HuiNuo RVDV-2H Digital Rotational Viscometer Packing list
Viscometer host X1, bracket X1, measuring flask X1, rotor X1 (sleeve), base and horizontal adjustment foot X1, temperature controller X1, thermal insulation cover X1, positioning frame X1, power cord X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1, RTD temperature sensor X1, heating furnace X1, special forceps pliers X1, connecting cable X1, connecting hook X2
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 41079.3-2024
- ActiveGB/T 8884-2017
- ActiveDL/T 660-2007
- ActiveEN 16896-2016
- ActiveASTM
- ActiveASTM D7945-2014
- ActiveDIN 53017-1993
- ActiveEN 12092-2001
- ActiveNF
- ActiveNF EN 12092-2002
- ActiveKS A0531-1993
- ActiveISO
- ActiveBS EN 12092-2001
- ActiveDIN EN 12092-2002
- ActiveJC/T 2678-2022
- ActiveGB/T 22427.7-2023
- ActiveGB/T 31424-2015
- AbolishGB/T 14235.8-1993
- ActiveGB/T 26930.11-2014
- ActiveJJG 2016-2015


RVDV-2H
RVDV-2
RVDV-2+SSA
RVDV-2+L0