TQC SP1681 adjustable cross-cut adhesion instrument set CC3000 series
2Mm cutter tooth spacing, 6 teeth; with auxiliary wheels to maintain a fixed distance; suitable for soft and strong substrates; vacuum hardened stainless steel cutter head.
-
Pushen HGQ 1 * 5 Multi-blade Cross Hatch Cutter Suitable for hard substrates less than 60μm
$ 179.00 -
TQC SP3000 Adhesion Tester Cross-cut Guide Gauge/Baige Plate 6-in-1 Multifunctional Adhesion Tester
$ 326.00 -
TRUIT TR 5001/2 Cross-cut adhesion instrument 1mm/11 teeth
$ 145.00 -
JFL 1mm11 Blade Cross Hatch Cutter Blade
$ 78.00 -
MODERNER QFH 2mm (10 slots) Cross Hatch Cutter 11 Blades 2mm Pitch
Login
Introduction to the cross-hatch method test with a hundred-grid knife
The hundred-square knife is an instrument manufactured based on the principle of the cross-hatch adhesion test and used to measure the adhesion of paint films. It is used to evenly draw squares of a certain size and evaluate the coating film by evaluating the integrity of the coating film within the square. The degree of adhesion to the substrate is expressed in 'grade'. It is mainly used to measure the adhesion of organic coatings using the cross-hatch method. It is not only suitable for laboratories, but also for construction sites under various conditions.
The "cross-hatch method" is widely accepted in CHINA and has also been rated by international standards as a quick and effective method to measure adhesion. There are various styles and methods of adhesion test of the grid knife, and they have been used to evaluate the adhesion of paint coatings.
During the adhesion test, there are many influencing factors, such as the flexibility of the paint, whether there is an interference layer (whether there is an interference layer between the paint and the substrate), etc. The cross-hatch method mainly uses a hundred-grid knife with single-piece or multi-piece cutting. After development, there are many more functional, more convenient and effective models that can directly display the adhesion of the product under test.

Introduction
The TQC CC3000 series of adjustable crosshatch adhesion Testers imported from the Netherlands are available in five models: SP1680, SP1681, SP1682, SP1683, and SP1684 . The accuracy can be adjusted according to specific testing needs to achieve precise cutting depth, thereby more accurately testing the adhesion test. Focus. Compared with other brands and other types of hundred-grid knives, this set of hundred-grid knives has knife sizes that can be used for different coating film thicknesses and substrates according to standards. It can be applied to a variety of adhesion tests by just adjusting, which is very convenient. Each set of 100-grid knives is composed of lightweight, comfortable handles and tough knives, with easy-to-carry specifications. Also includes brushes, small magnifying glass, and tape.

Product details




Related supporting products of Baige Knife
[need to be purchased separately]
SP9700 illuminated magnifying glass 2.5x
SP1710 nylon brush for adhesion testing
SP3020 tape, one roll, adhesion 7.6 N/cm
SP3007 tape, one roll, adhesion 4.3 N/cm
SP3010 tape, three rolls, adhesion 4.3 N/cm
TQC adhesIon Meter full series model comparison chart
| TQC | Teeth | CC1000 | CC2000 | CC3000 | Suitable for thick film environment |
| cross-hatch adhesion Tester | - | Self-adjusting blade holder, round cutter with 8 cuts | Self-adjusting blade holder allows for easy changing of the cutter, with a rotating handle and no additional tools required | The blade holder maintains a fixed distance between the paint surface and the two auxiliary wheels, and the cutting depth can be accurately adjusted to ensure repeatability. | - |
| ISO2409/ASTM D3359 | 1 | VF1839 | SP1690 | SP1680 | ISO2409: 0~60μm (solid substrate) ; ASTM D3359: 0~50μm (solid substrate) |
| ISO2409 / ASTM D3359 | 2 | VF1842 | SP1691 | SP1681 | ISO2409: 0~60μm (soft substrate), 61-120μm (firm substrate ) ; ASTM D3359: 50~125 μm (solid substrate) |
| ISO/DIN2409 | 3 | VF1844 | SP1692 | SP1682 | 121-250μm (solid substrate ) |
| ASTM 3359ï¼2009 | 1 | VF1846 | SP1699 | SP1683 | 0~50μm (solid substrate ) |
| ASTM 3359 is less than 2009 | 1.5 | VF1847 | SP1700 | SP1684 | 50~125μm (solid substrate ) |
Take you into the Dutch TQC



TQC sheen SP1681 Adjustable cross-cut adhesion TesterSpecifications
| LIST | VALUE |
|---|---|
| Number of teeth | 6 teeth |
| Tooth spacing | 2mm |
| Instrument material | Vacuum hardened stainless steel, aluminum, rubber |
| Application standard | ISO2409、ASTM D3359 |
| Applicable film thickness environment | 0~60µm (soft substrate), 61~ 120µm (solid substrate), 50~125μm (solid substrate) |
| Appearance size | 32*190*42mm |
| Instrument Weight | 352g |
TQC sheen SP1681 Adjustable cross-cut adhesion Tester Packing list
Cross Hatch Cutter x1, 3M Tape x1, Brush x1, magnifying glass x1, Encasement box x1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveJJF 2163-2024
- ActiveSJ 20910A-2018
- ActiveGB/T 9286-2021
- ActiveGB/T 23997-2009
- ActiveHG/T 20720-2020
- ActiveHG/T 5776-2020
- ActiveHG/T 5187-2017
- ActiveHG/T 5183-2017
- ActiveHG/T 5299-2018
- ActiveHG/T 3829-2006
- ActiveASTM D3359-2023
- ReplacedJG/T 210-2007
- AbolishISO 2409-2007
- ReplacedGB/T 9286-1998
- ActiveASTM D6677-2022
- AbolishISO 2409-1992
- ActiveHG/T 2003-1991
- ActiveGB/T 13492-1992
- ActiveJB/T 7217-2008
- ActiveJB/T 7663.2-2007


TQC sheen
SP1681