HUINUO HBDV-1 digital display Rotational Viscometer 4 million CP with a small number of sample adapters
Measurement range 80~40000000mPa · s, rotor specifications R2, R3, R4, R5, R6, R7, 21 #, 27 #, 28 #, 29 #, reproducibility +/- 0.5% F. S, Measurement accuracy +/- 1% F. S, capacity 10~20mL, Rotation speed Control mode continuously variable.
HuiNuo-
FANGRUI SSR Small Sample Adapter
$ 304.00 -
CNSHP NDJ-1S Digital Rotational Viscometer
$ 411.00 -
NIRUN 200 series, standard solution (not sold separately)
$ 145.00 -
HUINUO NDJ-8S digital Rotational Viscometer Viscosimeter with L0 rotor
$ 665.00 -
HuiNuo NDJ-8S + micro printer rotational viscometer Viscosity meter
$ 459.00
Introduction
The LCD screen of the RVDV-1 digital display rotary viscometer can display viscosity, shear rate, shear stress, rotational speed, temperature, percentmeter torque, rotor number and the maximum viscosity value that can be measured by the selected rotor at the current speed. It is a measuring range of 80~40,000,000 mPa · secondstargetDigital rotary viscometer。

Introduction to small sample adapters
It is equipped with 21, 27, 28 and 29 rotors
The sample volume is small, only 10~20mL, especially suitable for valuable sample testing
A thermostat connected to an external circulation function controls the temperature of the sample to be measured
Easy to disassemble and easy to clean

Viscometer structure diagram

HuiNuo HBDV-1+SSA Digital Rotational ViscometerSpecifications
| LIST | VALUE |
|---|---|
| Measurement range | 80~40000000mPa·s |
| Rotor specification | R2、R3、R4、R5、R6、R7、21#、27#、28#、29# |
| reproducibility | ±0.5%F.S |
| Measurement Accuracy | ±1%F.S |
| Power supply Voltage | Dedicated power adapter (input 100~240V 50~60Hz) |
| Rotor speed | 0.1~99.9rpm |
| Display information | Viscosity, Rotation speed, temperature, percentile torque, rotor number and the maximum viscosity value of the selected rotor at the current Rotation speed |
| Capacity | 10~20mL |
| Rotation speed Control mode | CVT |
HuiNuo HBDV-1+SSA Digital Rotational Viscometer Packing list
Host X1, protective frame X1, rotor X1 (set), base and horizontal adjustment bolt X1, lifting frame and lifting mechanism X1, special power adapter X1, wrench X1 Small sample adapter X1 (set)
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- ActiveGB/T 41079.3-2024
- ActiveQB/T 2568-2002
- ActiveEN 16896-2016
- ActiveDB 13/T 5026.1-2019
- Active 0978-2019
- ActiveBS
- ActiveASTM D4402/D4402M-2015
- ActiveJIS R1652-2003
- ActiveASTM
- ActiveASTM D7945-2014
- ActiveBS
- ActiveBS
- ActiveASTM E3116-2018
- ActiveHG/T 3323-2008
- ActiveDIN 53017-1993
- ActiveBS
- ActiveEN 12092-2001
- ActiveNF
- ActiveNF EN 12092-2002
- ActiveKS A0531-1993


HBDV-1+SSA
HBDV-1
HBDV-1+L0
HBDV-1H