China and domestic (CN) NBC-150B Thermal Shock Test Chamber 18KW/150L
Test Chamber Temperature Impact Range High Temperature Box: + 50 ° C~ 180 ° C; Low Temperature Box: 0 ° C~ -55 ° C, Temperature Fluctuation +/- 2 ° C;, Temperature Error +/- 2 ° C;, Heating Rate from Room Temperature~ 180 ° C ≤ 30min;, Cooling Rate from Room Temperature~ -55 ° C ≤ 60min.
Factory-
Aipei 2AP-CJ-50A Two-Chamber Thermal Shock Test Chamber Air-Cooled -40 ℃
$ 14031.00 -
Aipei 3AP-CJ-50B three boxes of air-cooled hot and cold impact test chamber -55 ℃
$ 17109.00 -
HUDA hatchback basket type air-cooled hot and cold impact test box QD-E703-50K55
$ 12060.00 -
China and domestic (CN) NBC-150B Thermal Shock Test Chamber 18KW/150L
$ 16669.00 -
ZKHS WDCJ-340C Thermal Shock Test Chamber, temperature Thermal Shock Test Chamber -60 ℃~ 150 ℃
$ 33339.00
The NBC-150B Thermal Shock Test Chamber is mainly used to test the resistance of materials to extremely high or low temperatures, which is similar to the situation of discontinuous high or low temperatures, and the thermal shock test can make various items complete the test in the shortest time. The changes or physical injuries caused by thermal shocks are caused by changes in thermal expansion and contraction or other physical values, and all kinds of products can be fully trusted by using the PID system. The effects of thermal shock include electrochemical changes caused by cracking or breaking layers and displacement of the finished product, and the full digital automatic control of the PID system will make it easy for you to operate.
The thermal shock testing machine is a necessary testing equipment for metal, plastic, rubber, electronics and other materials industries, which is used to test the material structure or composite materials, which can withstand the degree of continuous environment of extremely high temperature and extremely low temperature in an instant, so as to detect the chemical changes or physical injuries caused by thermal expansion and contraction of the test sample in the shortest time. It is divided into two-box and Three-Chamber, the difference is that the test method and internal structure are different, and the product meets the requirements of the standard for: GB/T2423.1-2008 test A, GB/T2423.2-2008 test B, GB-T10592-2008, GJB150.3-198, GJB360A-96 method 107 temperature shock test.
Application
Thermal shock Test Chambers are widely used in electronic and electrical components, automation parts, communication components, auto parts, metals, chemical materials, plastics and other industries, national defense industry, aerospace, military industry, BGA,PCBBase wrench, electronic chipIC, the physical changes of semiconductor ceramics and polymer materials, testing the repeated tensile force of the materials to high-low temperatures and the chemical changes or physical damage of the products in thermal expansion and contraction, can confirm the quality of the products, from precision ICs to heavy mechanical components, can be used as the basis or reference for product improvement.
Meets standards
GB-2423.1-89 (IEC68-2-1) Test A: Low temperature test method
GB-2423.2-89 (IEC68-2-2) Test B: High temperature test method
GJB360.8-87 (MIL-STD-202F) High Temperature Life Test
GBJ150.3 (MIL-STD-810D) High Temperature Test Method
GJB150.4 (MIL-STD-810D) Low Temperature Test Method
National military standard GJB150.3-86
National military standard GJB150.4-86
National military standard GJB150.5-86
Factory NBC-150B Thermal Shock Test ChamberSpecifications
| LIST | VALUE |
|---|---|
| Test Chamber Temperature Impact Range | High temperature box: + 50 ℃~ 180 ℃; Low temperature box: 0 ℃~ -55 ℃ |
| Temperature Fluctuation | ±2℃; |
| temperature error | ±2℃; |
| Cooling rate | From room temperature~ -55 ℃ ≤ 60min; |
| Power Supply | 380V±38V50Hz±1Hz |
| Power | About 18Kw |
| Hanging basket load-bearing | Within 20Kg. |
| Volume L | 150L |
| Temperature and Humidity Control Instrument | Programmable platform Controller, touch screen input, Chinese and English switching. Different temperature points can be arbitrarily set according to customer requirements |
| Box structure | This equipment is divided into: high temperature zone, low temperature zone |
| Test area size | 600 * 600 * 420 (width * depth * height) * 2 |
| Exterior size approx. | 1390x2120x1820mm |
| Test Temperature Impact Range | -40 ℃~ + 150 ℃ (optional programming setting) |
| Temperature range of high temperature box | + 60 ℃~ + 180 ℃ (optional programming setting) |
| Temperature range of cryogenic chamber | 0 ℃~ -55 ℃ (programmable arbitrary setting) Temperature range -40---150 degrees |
| Temperature transition time | 10 seconds (time can be specified) |
| Controller control Accuracy | ±0.2℃ |
| shell material | Sheet metal paint |
| Inner box material | SUS #304 Thickened heat-resistant and cold-resistant stainless steel plate, first-class light panel |
| Thermal Insulation | High density Glass cotton and high strength PU foam insulation materials have good thermal insulation effect |
| box uniformity | ±2 |
| Air supply circulation system | Japanese multi-wing centrifugal Circulating Fan, Japanese motor whole group |
| heater | U-shaped fin type 304 #seamless steel high-speed heating electric heater. |
| Refrigeration compressor | Adopt imported Compressor unit |
| Refrigeration accessories | Table bending center force evaporator, Mar fan, etc |
| Refrigeration method | Adopt water-cooled heat dissipation (water towers, pipes, the buyer installs them by himself) |
| Sample holder | Hanging Basket |
| Electrical accessories | Domestic well-known brand electrical components |
| wiring method | The company's electronic control wiring method is implemented in accordance with international electrical standards |
| Protection device | Compressor overheating, overtemperature, overload, high Voltage, low pressure, oil pressure, overcurrent, under-phase, power failure standby and other alarm warnings., |
| Power Supply | AC380V 50~60Hz 18KW |
| Meet the standard | GB2423 [1] .02 High temperature test method, GB2423 [1] .01 Low temperature test method. |
| Weight | 750KG |
Factory NBC-150B Thermal Shock Test Chamber Packing list
host X1, manual X1, certificate X1, warranty card X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.
FAQ
- "Two-Chamber" and "Three-Chamber" heat & cold shock boxes, which one is more suitable for you?
- Thermal Shock Test Chamber for printed circuit boards
- What are the similarities between the two-box thermal shock Test Chamber and the Three-Chamber thermal shock Test Chamber?
- Thermal Shock Test Chamber FAQ and calibration method
- What is the difference between the two-box thermal shock Test Chamber and the Three-Chamber thermal shock Test Chamber?
- Working Principle, Failure and Application of Thermal and Cold Shock Test Chamber
- What is the difference between the two-box thermal shock Test Chamber and the Three-Chamber thermal shock Test Chamber?
- Principle, Application and Selection of Main board Thermal Shock Test Chamber
- Confusion: What is the difference between constant temperature and humidity Test Chamber, high-low Temperature Test Chamber, thermal shock Test Chamber and rapid temperature change chamber?
- What parts of Thermal Shock Test Chamber need to be cleaned frequently?
- IncomingGB/T 46603-2025
- ActiveJG/T 572-2019
- ActiveQB/T 5822-2023
- ActiveISO 14188-2012
- ActiveGB/T 34180-2017
- ActiveGB/T 14152-2001
- ActiveGB/T 15727-1995
- ActiveGB/T 42259-2022


NBC-150B