FANGZHOU PHBJ-360 Portable pH Meter PH acid alkalinity Tester 0.01 grade
It is suitable for out-of-home measurement of sample pH value, and can stably and accurately measure sample pH, mV, ORP, T. There are two methods for measuring ORP: ORP relative to the reference electrode potential difference, ORP relative to the hydrogen standard electrode potential difference
FZchina-
LEICI 962223 RoHS pH composite electrode for RoHS compliance
$ 242.00 -
Qiwei PH-20B Pen Acidity Meter (Backlit)
$ 99.00 -
FANGZHOU FZ-853-H PH Glass electrode with temperature probe 0~130 ℃
$ 452.00 -
HANNA HI10482 Bluetooth Glass acidity electrode for wine/juice
$ 562.00 -
Qiwei PHS-3CW pH meter (desktop microcomputer)
$ 145.00
Applicable scenarios
It is suitable for measuring the pH value of the sample out, and can stably and accurately measure the pH, mV, ORP, and T of the sample. Such as ultrapure water, pure water, water-based resin, water-based paint, gypsum powder, titanium dioxide, soil, protein, enzyme solution, TRIS buffer, PBS buffer, strong acid, strong alkali, wastewater, surface water, tap water, drinking pure water, etc.
Corresponding advantages
Continuously optimized parameters, iteratively upgraded in different measurement scenarios, ensure that samples are measured with pH, mV, and ORP to obtain good and safe data.
Features
Large-screen LCD display, support backlight adjustment, table display, menu navigation operation
Support Chinese and English language interfaces
3 temperature units available: Celsius (°C), Fahrenheit (°F), thermodynamic temperature (K)
It has functions such as self-diagnosis at power-on, automatic shutdown at a timed time, power-off protection and factory reset recovery
IP65 protection level is supported
Smart detection
Intelligent operating system with functions such as method setting, sensor management, calibration management, sample management, and user management
Allow users to set user ID, sample ID, support user hierarchical authority management, support password management
Supports measurement of pH, mV, RelmV, ORP, and T values
There are two ways to measure ORP: ORP relative to the reference electrode potential difference, and ORP relative to the hydrogen standard electrode potential difference
Built-in reference electrodes with 6 different configurations, Ag-AgCl electrode [saturated KCl], Ag-AgCl electrode [3mol/L KCl solution],
Ag-AgCl electrode [1mol/L KCl solution], calomel electrode [saturated KCl solution], calomel electrode [1mol/L KCl solution], calomel electrode [0.1mol/L KCl solution]
It can automatically identify 28 pH standards in 6 groups of GB, Merck, DIN19267, NIST, European, and United States, and the calibration points of the standard solution range from the minimum to 1.09 pH to the maximum 12.75 pH calibration, and the maximum 5 calibration points
It has electrode condition display, measurement limit, alarm function, and endpoint processing mode
ATC automatic recognition, automatic/manual temperature compensation
Five measurement modes: Manual Reading, Automatic Quick Reading, Automatic Medium Reading, Automatic Slow Reading, Timed Reading
ORP calibration is supported
Support 2 pH calibration fitting methods to meet the pH and ion concentration measurement of different samples
Dual clock and date display shows the current time and provides a time reference for digital recording functions
It has a timer storage function, and the timer storage time is: (5-3600) seconds
Data management and data traceability
Current and historical calibration data can be consulted, including calibration personnel, calibration temperature, calibration point pH and mV, slope, equipotential offset, calibration date and time
Support measurement value storage: Users and samples can be created dynamically, and no less than 5000 sets of data can be stored
GLP compliant, data traceability and statistical analysis are realized
With USB interface, the instrument can send the stored data to the computer acquisition software, and can export Excel files, notepad files, etc., which is convenient for users to archive and consult, statistical, analyze, compare and other operations of measurement data
power management
Powered by large-capacity lithium battery, it can be charged by mobile power bank and PC
It has the function of battery level display reminder and charging status reminder
Support backlight adjustment
FZchina PHBJ-360 Portable pH MeterSpecifications
| LIST | VALUE |
|---|---|
| Instrument level | 0.01 level |
| PH range | (-5.00~20.00)pH |
| pH resolution | 0.01pH/0.1pH (adjustable) |
| pH electron unit intrinsic error | ±0.01pH |
| Repeatability of pH electron unit | 0.01pH |
| mV range | (-2000.0~2000.0)mV |
| mV resolution | 0.1mV/1mV (adjustable) |
| mV/RelmV electronic unit intrinsic error | +/- 0.1% FS or +/- 0.2mV |
| ORP Measurement range | (-2000.0~2000.0)mV |
| ORP resolution | 0.1mV/1 mV (adjustable) |
| ORP electronic unit intrinsic error | +/- 0.1% FS or +/- 0.2mV |
| ORP Electronic Unit Repeatability | 1mV |
| ORP instrument matching error (ORP) | ±15mV |
| Measurement range | (-20.0~135.0)℃/(-4.0~275.0)℉/(253.15~408.15)K |
| Temperature Resolution | 0.1℃ |
| Temperature electronic unit intrinsic error | ±0.2℃ |
| Temperature compensation range | (-20.0~135.0) ℃ (automatic/manual) |
| Input Impedance | ≥1×1012Ω |
| Data storage | Storage quantity 5000 sets |
| GLP standard | GLP compliant |
| input/output | Sensors interface: electrode interface, temperature interface; Communication interface: USB Type-C |
| Power Supply | 4 14500 3.7V rechargeable lithium batteries |
FZchina PHBJ-360 Portable pH Meter Packing list
Host * 1, FZ-610T pH electrode * 1, wristband * 1, charger and USB Type-C charging cable * 1 set, short circuit plug * 1, pH standard buffer solution * 1 set/3 bottles, user manual, warranty card, certificate of conformity, suitcase
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.