Huazhike WT100P-24 multi-channel temperature Recorder, temperature Detector 24-channel Linear dispersion version
24-Channel, 5-inch touchscreen display, unique correction per channel, cold junction correction, over-limit alarm, list, Linear dispersion, bar chart
Wasites-
Wasites WT100P-56 Multi-channel Temperature Recorder, Temperature Linear dispersion Tester 56-channel Linear dispersion version
$ 1147.00 -
Handheld industrial thermometer HB6801 Hypertherm with K-type Thermocouple
$ 100.00 -
HANNA HI151-4 Thermometer, Green, Fruit Salad
$ 142.00 -
HANNA HI93531N Wide Range Temperature Meter (with Backlight and Adjustment)
$ 551.00 -
HANNA HI935002 Wide Range Temperature Meter (with Backlight and Adjustment)
$ 307.00
overview
This multi-channel temperature collector uses a 32-bit high-speed CPU for data processing, and adopts a 5-inch industrial systemThe display screen supports K J E T N S R B type thermocouple input, a variety of display methods, usersIt can read all parameters more intuitively, and the instrument has perfect functions, superior performance and simple operationSingle features to meet the needs of production, laboratory and R&D measurements.
It is widely used in lighting appliances, power tools, household appliances, motors, and electric heating appliancesPharmaceutical, petroleum, chemical, metallurgy, electric power and other industries and scientific research units and other fields of production enterprisesproduction lines, laboratories, and quality inspection departments.
According to the actual needs of the user, a variety of measurement functions can be customized to meet higher applications.
peculiarity
HD 5-inch IPS industrial-grade LCD touch screen with a resolution of 854X480
Using 32-bit high-speed MCU data processing + 24-bit high-speed AD measurement chip, the response speed is fast,High precision, stable and reliable.
Multi-interface display, file list, real-time list display, column chart display, real-time/record/Analysis curve display, alarm list, system settings, etc.
Support 4/8/16/32 multi-interface real-time value display.
Supports multiple sensor inputs: K J E T N S R B
Each channel can be set to use a different thermocouple type.
THE NAME OF EACH CHANNEL CAN BE CUSTOMIZED, AND THE CUSTOM NAME CAN BE EXPORTED TO EXCEL.
The Voltage difference between channels can be as high as AC/DC 350V, which has super anti-interference ability
Each channel can have sound and light alarm function. Independently set the alarm value of too high or too low
Independent error correction for each channel Y=KX+B
The built-in 8G large memory file list display, which supports up to 64 files and 130,000 per fileGroup data, with 1 second intervals, can be recorded continuously for up to 97 days
Record files can be deleted and exported to disks and direct export files by single or multiple selections
Double relay alarm output. Standard communication interface USB RS485
With the communication address code setting, it can be used in parallel in multiple places and multiple machines, and the communication protocol can be provided
USB communication interface is standard, RS232 or RS485 communication interface can be selected
Modular design, 8 channels per module, up to 64 channels, automatic identification of capacity expansion
Multi-level alarm indication, HH, H, L, LL alarm setting and alarm indication (equipped with relay transmissionout), and you can view the historical alarm recording function
Principle

As shown in the figure, the instrument consists of a thermocouple, a photoelectric switch selector, an amplifier, A/D,Monolithic microcomputer, keyboard, display, communication, data memory, cold end compensation and other partsCompose.
The corresponding channel signal is selected by the photoelectric switch selector and passed through the signal amplifierThe signal is amplified, and then the analog signal is converted into a data signal through the AD converterThe single-chip microcomputer processes the data, and the cold-end compensation circuit measures the temperature at room temperature to obtain the coldEnd temperature value, measurement signal and cold end temperature value are processed by a single-chip microcomputerThe correct measured temperature value is displayed on the display.
Keyboard, communication, and data memory can be used to set and store data on the displayReserve for analysis. It can also be connected to the computer through the communication interface and the data can be carried out directly by the computerAnalyse.
Panel features



Serial models
| WT100P-8 | WT100P-16 | WT100P-24 | WT100P-32 | WT100P-40 | WT100P-48 | WT100P-56 | WT100P-64 |
| Route 08 | Route 16 | No. 24 | No. 32 | No. 40 | No. 48 | No. 56 | No. 64 |
| 5-inch touch screen display, unique correction per channel, cold end correction, over-limit alarm, list, curve, column chart | |||||||
Wasites WT100P-24 Multi-channel temperature Recorder (Linear dispersion version)Specifications
| LIST | VALUE |
|---|---|
| Display mode | 5 inch TFT true color LCD industrial touch screen 854 * 480 pixels |
| display format | Real-time list, Linear dispersion (historical Linear dispersion), bar chart, current alarm (historical alarm), file record list. |
| record query | This machine view records Linear dispersion, historical alarm records, computer software analysis query.. |
| Thermocouple | KJETNSRB |
| Basic Precision | 0.2 ℃ + 2 characters (without Thermocouple error) |
| Measurement range | -200~1820 ℃ (subject to Thermocouple indexing range) |
| cold junction compensation | Accuracy: 0.5 ℃ |
| resolution | 0.1℃ |
| correction | Independent error correction per channel Y = kx + b (x = Measured value) |
| Number of files | 64 (cyclic record) |
| file Capacity | A file can record the number 130,000 groups (without distinguishing between Number of channels) |
| U disk interface | Export record files, change the U disk function in seconds (the instrument is a U disk), and directly view files and software. |
| recording time | The 1-second recording interval can be recorded continuously for 97 days, and the total duration is calculated = the recording interval is X97 days. |
| Sampling speed | Fast per channel: 0.1S, slow: 1S |
| channel isolation | AC/DC up to 350V, high Voltage live measurement, super anti-interference ability |
| Control output | Two independent relay outputs, namely (H/L) and (HH/LL) relays |
| Alarm sound | Buzzer sound all the way (sound at any alarm, can be set to mute) |
| recording interval | 1-9999 seconds arbitrary setting |
| Communication interface | Standard USB, RS485 |
| Power supply | AC85-265V + 10%, Frequency 50Hz/60Hz < 10W |
| Thermocouple | One 2m K Thermocouple per channel |
| size | Width 220X Depth 293X Height (including feet) 1 06mm |
| Weight | About 3Kg (different configurations vary) |
| environmental conditions | 5~ 40 ℃, 20%~ 80% RH (no condensation) |
Wasites WT100P-24 Multi-channel temperature Recorder (Linear dispersion version) Packing list
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


WT100P-24
WT100P-64
WT100P-56
WT100P-48
WT100P-40
WT100P-32
WT100P-16
WT100P-8