HANNA HI93701-01 Photometer reagent residual chlorine 100 times
Reagent name residual chlorine, range 0.00 to 5.00 mg/L (as Cl2), 100 times.
HANNA-
DDKSIC DO100 laboratory Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
$ 574.00 -
YUEFENG SZ81111 Chlorine dioxide analyzer, chlorine dioxide concentration analysis 0~ 5.0mg/L
$ 345.00 -
LEICI 780800N01 residual chlorine kit for DGB-402A, DGB-402F, DGB-403F
$ 110.00 -
YUEFENG SZ8116 iron analyzer, iron content analyzer 0~ 0.8mg/L
$ 345.00 -
HANNA HI98193 dissolved oxygen DO-biochemical oxygen demand BOD Tester
$ 1368.00
Luminometer routine reagents are a range of reagents for measuring the concentration of different chemical substances, designed for a variety of analytical needs. These reagents are able to react with target chemicals in a photometer to provide accurate measurements. Different types of reagents are suitable for the determination of ammonia nitrogen, residual chlorine, total chlorine, copper, nitrite, manganese, aluminum, iodine, calcium hardness, magnesium hardness, iron, hexavalent chromium, nickel and nitrate and other chemical substances from low to high concentrations, and each reagent provides 100 tests (except for some models such as high concentration ammonia nitrogen reagents can reach 300 times). These reagents are widely used in water analysis and environmental monitoring to ensure accurate and reliable measurement of chemical concentrations in a wide range of liquid samples.
HI93701-01 is a pre-measured, high-quality reagent that allows users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD method, in which the reaction between chlorine and the reagent results in the appearance of a pink color in the sample. The intensity of the color is determined by a compatible photometer and the concentration will be displayed. The results will show the concentration of chlorine (mg/L). These reagents are designed for samples with an expected range of 0.00 to 5.00 mg/L free chlorine.
Conventional reagents for photometers
| Model | name | range | frequency |
| HI93700-01 | Low concentration of ammonia nitrogen | 0.00~3.00 mg/L (as NH3-N) | 100 |
| HI93715-01 | Medium concentration of ammonia nitrogen | 0.00-10.00mg/L | 100 |
| HI93733-01 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 100 |
| HI93733-03 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 300 |
| HI93701-01 | Residual chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93711-01 | Total chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93702-01 | copper | 0.00~5.00 mg/L (as Cu) | 100 |
| HI93707-01 | Low concentration of nitrite | 0~600 μg/L (as NO2-N) | 100 |
| HI93708-01 | High concentration of nitrite | 0~150 mg/L (as NO2-) | 100 |
| HI93709-01 | manganese | 0.0~20.0 mg/L (as Mn) | 100 |
| HI93712-01 | aluminium | 0.00~1.00 mg/L (as Al3+) | 100 |
| HI93718-01 | iodine | 0.0~12.5 mg/L (as I2) | 100 |
| HI93719-01 | Magnesium hardness | 0.00~2.00 mg/L (as CaCO3) | 100 |
| HI93720-01 | Calcium hardness | 0.00~2.70 mg/L (as CaCO3) | 100 |
| HI93721-01 | iron | 0.00~5.00mg/L(ppm)Fe | 100 |
| HI93723-01 | Hexavalent chromium | 0~1000 μg/L (as Cr(VI)) | 100 |
| HI93726-01 | nickel | 0.00~7.00 g/L (as Ni) | 100 |
| HI93728-01 | nitrate | 0.0~30.0 mg/L (as NO3--N) | 100 |
HANNA HI93701-01 PhotoMeter ReagentSpecifications
| LIST | VALUE |
|---|---|
| reagent name | residual chlorine |
| scope | 0.00~5.00 mg/L (as Cl2) |
| number of times | 100 times |
HANNA HI93701-01 PhotoMeter Reagent Packing list
Reagent X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI93701-01






