HANNA HI93708-01 Photometer reagent, high concentration of nitrite 100 times
Reagent name High concentration nitrite, range 0~150 mg/L (as NO2-), the number of times 100.
HANNA-
LEICI iodine ion electrode calibrated solution, suitable for iodine ion composite electrode
$ 107.00 -
DDKSIC DO10 portable color screen Dissolved Oxygen Meter (polarographic type) dissolved oxygen concentration/dissolved oxygen saturation/℃
$ 572.00 -
LEICI 781900N00 Aluminum Ion Kit for DGB-427
$ 159.00 -
LEICI potassium ion electrode calibrated solution, suitable for potassium ion composite electrode
$ 107.00 -
TONGAO TR-718H Copper Water Quality Analyzer, Copper Ion Tester
$ 792.00
Luminometer routine reagents are a range of reagents for measuring the concentration of different chemical substances, designed for a variety of analytical needs. These reagents are able to react with target chemicals in a photometer to provide accurate measurements. Different types of reagents are suitable for the determination of ammonia nitrogen, residual chlorine, total chlorine, copper, nitrite, manganese, aluminum, iodine, calcium hardness, magnesium hardness, iron, hexavalent chromium, nickel and nitrate and other chemical substances from low to high concentrations, and each reagent provides 100 tests (except for some models such as high concentration ammonia nitrogen reagents can reach 300 times). These reagents are widely used in water analysis and environmental monitoring to ensure accurate and reliable measurement of chemical concentrations in a wide range of liquid samples.
HI93708-01 is a pre-measured, high-quality reagent that allows users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the ferrous sulfate method, in which the reaction between the nitrite and the reagent results in a color change in the sample. The intensity of the color is determined by a compatible photometer, and the concentration will be displayed in milligrams per liter (ppm) nitrite. These reagents are designed for samples with an expected range of 0 to 150 mg/L nitrite.
Conventional reagents for photometers
| Model | name | range | frequency |
| HI93700-01 | Low concentration of ammonia nitrogen | 0.00~3.00 mg/L (as NH3-N) | 100 |
| HI93715-01 | Medium concentration of ammonia nitrogen | 0.00-10.00mg/L | 100 |
| HI93733-01 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 100 |
| HI93733-03 | High concentration of ammonia nitrogen | 0.0~100.0 mg/L (as NH3+) | 300 |
| HI93701-01 | Residual chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93711-01 | Total chlorine | 0.00~5.00 mg/L (as Cl2) | 100 |
| HI93702-01 | copper | 0.00~5.00 mg/L (as Cu) | 100 |
| HI93707-01 | Low concentration of nitrite | 0~600 μg/L (as NO2-N) | 100 |
| HI93708-01 | High concentration of nitrite | 0~150 mg/L (as NO2-) | 100 |
| HI93709-01 | manganese | 0.0~20.0 mg/L (as Mn) | 100 |
| HI93712-01 | aluminium | 0.00~1.00 mg/L (as Al3+) | 100 |
| HI93718-01 | iodine | 0.0~12.5 mg/L (as I2) | 100 |
| HI93719-01 | Magnesium hardness | 0.00~2.00 mg/L (as CaCO3) | 100 |
| HI93720-01 | Calcium hardness | 0.00~2.70 mg/L (as CaCO3) | 100 |
| HI93721-01 | iron | 0.00~5.00mg/L(ppm)Fe | 100 |
| HI93723-01 | Hexavalent chromium | 0~1000 μg/L (as Cr(VI)) | 100 |
| HI93726-01 | nickel | 0.00~7.00 g/L (as Ni) | 100 |
| HI93728-01 | nitrate | 0.0~30.0 mg/L (as NO3--N) | 100 |
HANNA HI93708-01 PhotoMeter ReagentSpecifications
| LIST | VALUE |
|---|---|
| reagent name | High concentration of nitrite |
| scope | 0~150 mg/L (as NO2-) |
| number of times | 100 times |
HANNA HI93708-01 PhotoMeter Reagent Packing list
Reagent X1
[Note] Because the manufacturer's packaging may be updated or upgraded, the detailed packaging list shall be subject to the latest standard configuration of the manufacturer.


HI93708-01